HomeMy WebLinkAboutOWTS Design Report 01.06.2021Design Calculations For Tarin Residence on-site Wastewater Treatment System 0405 County Road 104 Carbondale, Colorado January 6, 2021 CIVCO Engineering Inc Civil Engineering Consultants Vernal, Utah 1256 W. 400 S. Office: 435-789-5448 P.O. Box 1758 Fax: 435-789-4485 Vernal, L T 84078 www.civcocngineering.cam J 1 CIVCO Engineering, Inc. PO Box 1758, Vernal, UT, 84078 Ph: (435)789-5448 Fx: (435)789-4485 TARIN 0405 County Road 104 Parachute, Colorado Referenced Calculations Description OWTS SIZING Page 1 By: WK Date: 12/08/2020 Chk'd: wk Date: 01/06/2021 Section contains calculations sizing the components of the On-site Wastewater Treatment System. Design Standards Garfield County Resolution 2018-36 GCR Site Investigation A backhoe excavator was used to dig two 9 -foot deep profile holes near the proposed location of the Tarin on-site wastewater treatment system (OWTS) soil treatment area. Graphic logs of both profile holes are shown in the construction drawing for the OWTS. No standing water, nor evidence of previous groundwater level, was encountered in either profile hole. Percolation test locations were also prepared and presoaked. Percolation test holes were 10" to 12" in diameter and 12" to 13" deep below the presumed infiltrative surface at 2' below ground level. Percolation tests were performed the following day. The percolation test data is tabulated on Sheet 2 of this document. The approximate locations of wells, water supply lines, property lines, and buildings were noted and are shown on the OWTS construction drawing. A 100 -foot offset radius for the water well, a 10 -foot offset line for the property boundary, and a 25 -foot offset line for the water supply line are all noted on the construction drawing as well. According to Google Earth data, the property slopes north -to -south at approximately 9% in the vicinity of the proposed OWTS. OWTS SIZING - tarin2.mcdx CIVCO Engineering, Inc. PO Box 1758, Vernal, UT, 84078 Ph: (435)789-5448 Fx: (435)789-4485 TARIN 0405 County Road 104 Parachute, Colorado Number of Bedrooms Ned==3 Perk Test Results: OWTS SIZING Page 2 By: WK Date: 12/08/2020 Chk'd: vvk Date: 01/06/2021 Minutes Elapsed Test Hole 1 Test Hole 2 Test Hole 3 Water Level Drop lin.) Perk Rate (Min./In.) Water Level Drop (in.) Perk Rate jMin./In.) Water Level Drop (in.) Perk Rate (Min./In.) 30.00 1.5625 19.20 1 30.00 1.5 20.00 60.00 1.1875 25.26 0.625 48.00 1.125 26.67 90.00 0.875 34.29 0.625 48.00 1.125 26.67 120.00 0.75 40.00 0.5 60.00 1 30.00 150.00 0.625 48.00 0.625 48.00 1.125 26.67 180.00 0.5 60.00 0.625 48.00 0.875 34.29 210.00 0.625 48.00 1.125 26.67 0.875 34.29 240.00 0.5 60.00 0.625 48.00 0.625 48.00 Hole Perk Rate: 60.00` 48.00; 48.00 Ave. Perk Rate: 52.00 SEPTIC TANK Required Tank Volume V := if Ned<3 11(1000•gal) else II(�(_3).259 [GCR TABLE 9-1] =I 000ga/ First Compartment Volume 16St comp°= OWTS SIZING - tarin2.mcdx if NNad<3 =500 ga/ II (500.9x/) else II500 • gal+ (A/0„/- 3) • 125.667 [GCR 43.9.B.4.a] CIVCO Engineering, Inc. PO Sox 1758, Vernal, UT, 84078 Ph: (435)789-5448 Fx: (435)789-4485 SOIL TREATMENT AREA Design Flow Q:= TARIN 0405 County Road 104 Parachute, Colorado if lvd<22 300 �`?! else if Nom= 3 450 gal day else if Nd> 3 450 gal (A/ —3) 75 gal day day Long-term Acceptance Rate (LTAR) Perk Rate OWTS SIZING Page 3 By: WK Date: 12/08/2020 Chk'd: wk Date: 01/06/2021 =450 gal [GCR Table 6-1] day gal t:=ta,e=52 mm Type 3 soil.... LTAR:= 0.35 d aY in fi2 [GCR Table 10-1] Unfactored Soil Treatment Area 5TA:= =1285.71 62 LIAR Soil Treatment Area (Factored for Bedded Chambers)... Application Method Size Adjustment Factor.... 5AFAM:= 1.2 (gravity) Distrlb. Media Size Adjustment Factor SAP,M:=0.7 (chambers) [CCR Table 10-2] [CCR Table 10-3] Cumulative Size Adjustment Factor.... SAF=if 5AFAM•.5AFQM>0.5 =0.84 II5AFAM• 5AFoM else 114:15 [CCR 43.10.D.3] Bedded Chambers Soil Treatment Area 5TA5c:= 5AF• 5TA= 1080 ft 2 Chamber Bottom Width 85:= 34 in Required Bedded Chamber Length 5 B ®c =381.18 fit OWTS SIZING - tarin2.mcdx CIVCO Engineering, Inc. PO Box 1758, Vernal, UT, 84078 Ph: (435)789-5448 Fx: (435)789-4485 TARIN 0405 County Road 104 Parachute, Colorado OWTS SIZING Page 4 By: WK Date: 12/08/2020 Chk'd: wk Date: 01/06/2021 REQUIRED SOIL TREATMENT AREA MI FT.) = 1080. NUMBER OF CHAMBERS PER ROW NUMBER OF ROWS IN SOIL TREATMENT AREA 1 . 2 3 4 4 5 6 7 C EAMBR , MAKE &MODEL INFILTRATOR QUICK 4 PLUS EFFECTIVE CHAMBER WIDTH (INCH) = 34 EFFECTIVE CHAMBER LENGTH (INCH) = 48 MINIMUM TOTAL CHAMBER LENGTH (FEET) = 381 ---- . __ 24 _ -- -- ADS BIODiFFUSER EFFECTIVE CHAMBER WIDTH (INCH) = 34 EFFECTIVE CHAMBER LENGTH (INCH) = 75 MINIMUM TOTAL CHAMBER LENGTH (FEET) = 381 -- -- -- 16 --- -- Laterals may not exceed 100feet in length [GCR 43.10.E.2.c] Bed width may not exceed 12 feet. [GCR43.10.F.2.a] OWTS SIZING - tarin2.mcdx