Loading...
HomeMy WebLinkAboutOWTS Design Report 08.26.2019P.O. Box 1908 1011 Grand Avenue Glenwood Springs, CO 81602 Z4NCANELIA AND ASSOCIATES; INC ENGINEMING CONSULTANTS August 26, 2019 Mr. Hector Brown 172 County Rd 160 (or 172 Darrow St) Glenwood Springs, CO 81601 Re: Septic system capacity 172 Co Rd 160, Glenwood Springs, Co Hector, (970) 945-5700 (970) 945-1253 Fax We have reviewed the capacity of the existing septic system at the subject address and report as follows: 1. The system has a 1500 Gal. Concrete tank and a leach field of approximately 1300 square feet based on pumping the tank and review of available records. 2. Based on your description the existing leach field was a conventional one with gravel bedded perforated pipe. When the metal building was constructed. The part of the leach field in conflict with the building was removed and additional Infiltrators added along the east side of the building to augment the system. 3. The nearest water well facility is located approximately 195 feet to the north west and is outside the regulated setback. 4. The existing residences are 2 - 1 bedroom/1 bath and the 2 existing shop spaces have a single bathroom each. EQUIVILANT RESIDENTIAL UNIT (EQR) SUMMARY: 1 — shop area 1000 Sq. Ft 1/2 bath 1 — shop area 1000 Sq. Ft 1/2 bath 1 — residence 1068 Sq. Ft 1 BR/1 bath 1 — residence 619 Sq. Ft 1 BR/1 bath 5. The existing septic system and leach field are adequate to provide for up to 5 bedrooms of capacity per current regulations. With the shop functions utilizing one of bedroom of capacity this should allow for 2 additional bedrooms to be added to the system. Please advise me if additional information is required. Miele Zaircaff&la Thomas A Zancanella I P.E. Office970.945.5700 1970.379.2926 I Fax: 970,945.1253 tax c@za-engineeru Ig.Corn Zancanella & Associates Inc. I Engineering Consultants 1011 Grand Avenue I Glenwood Springs, CO 81601 lag OPTIONAL SIDE 7 LOCATION FOR INLET 1000-1500 GALLON RESIDENTIAL SEPTIC TANKS NON -TRAFFIC ACCEPTED BY UPC, 11 11 It 11 3W 11 11 11 11 TOP VIEW OPTIONAL 24" DIA. CONCRETE ACCESS COVER OR PARKWAY CAST IRON R & C. OPTIONAL 6" OR ^12" RISERS 4" PVC INLET & OUTLET PIPE AND FITTINGS STANDARD SIDE VIEW MODEL NUMBER �� CApAaiy GALLONS WIDTii 'A' LENGTH 1r HEIGHT 'G INLET If OUTLET 'E' MINIMUM EXCAVATION 1MDTH MINIMUM EXCAVATION LENGTH TANK WEIGHT LBS. JS-1000 1000 5'-1" 8'-2" 5'-8" 4'-10" 4'-7" 6'-1" 9'-2" 9,400 ' JS-1200 1200 5'-9" 8'-6" 5-8" 4'-10" 4'-7" 6'-9" 9'-6" 10,600 JS-1500 1500 5'-7" 10'-8" 5'-8" 4'-10" 4'-7" 6'-7" 11'-8" 12,400 TANK DESIGNED FOR NON -TRAFFIC USE WITH A MAXIMUM LOAD OF 500 PSF AND DRY SOIL CONDITIONS (WATER TABLE BELOW TANK). EARTH COVER OVER TANK NOT TO EXCEED 3', EFFLUENT FILTERS ARE AVAILABLE UPON REQUEST. FOR COMPLETE DESIGN AND PRODUCT INFORMATION CONTACT JENSEN PRECAST. 10/01/03 JS1DD0fhruJS1500_W.dwg O 2003 Jensen Precast THE DESIGN AND DETAIL OF THIS DRAWING ARE THE PROPERTY OF JENSEN PRECAST AND NOT TO BE USED EXCEPT IN CONNECTION WRH ITS OWN WORK, DESIGN AND INVENTION RIGHTS ARE RESERVED, JEIY5EIY Fixture count GPD Total 6 toilets 24.8 148.8 6 6 lay. 8.4 50.4 4 kitchen sinks 4.4 17.6 2 disposals 1.4 2.8 2 baths 14.7 29.4 2 laundry 8.4 16.8 One per floor Total GPD 265.8 GPD Which is Tess than 5 bedrooms 75 5 375 GPD