Loading...
HomeMy WebLinkAboutEngineer's Letter - Deviations from Structural Drawings 08.22.2019CIVCO Engineering, Inc. Civil Engineering Consultants P.O. Box 1758 365 West 50 North, Suite W-1 Vernal, Utah 84078 August 22, 2019 Shawn Ruse Clayton Homes 671 23 Road Grand Junction, CO 81505 Dear Shawn, Subject Mountain Shadow Place Development, Glenwood Springs, CO The following deviations may be made from the structural drawings that I prepared (dated 03/18/19): • The concrete wall separating the crawlspace area from the lower level living space may be replaced with a framed wall of 2x6 studs @ 16" o.c. sheathed with gypsum board as required for fire separation. Within the wall, provide a 4 -ply 2x6 column that will catch the LVL beam that is over the living space at the marriage line. • The framed wall in the crawlspace along the marriage line may be omitted and replaced with 6x6 columns at locations specified by the home manufacturer. Under each column, center a 20" x 10" x 70" (w x d x I) footing that is reinforced with three #4 rebar in each direction. Sincerely, Vance V. King, PE Engineer CIVCO Engineering, Inc. VVK/vvk Cc: Project File Phone (435)789-5448 * Fax (435)789-4485 Email: vancekingecivcoengineering.com