Loading...
HomeMy WebLinkAboutRevisions to Approved Plans 11.19.2020GENERAL NOTES DE516N CRITERIA: I. Building Code IBC 2015 2. Risk Category II 3. Loads A. Dead I. Roof 15 psf 2. Floor, Attic, Ceiling, Deck 15 psf 3. Porch BO psf B. Live I. Roof 20 2. Floor office 65 3. Porch 50 4. Overlook, Stairs, Landings, Deck 100 5. Attic, Ceiling 20 G. Snow I. Flat -roof Snow Load (Pf) 40 psf 2 Snow Exposure Factor (Ce) ID 3. Snow Load Importance Factor (Is) 10 4. Thermal Factor (GO ID D. Wind I. Basic Wind Speed (3 -second gust) 2. Hind Importance Factor (1w) 3. Wind Exposure E. Seismic I. Seismic Importance Factor (IE) 2. Mapped Spectral Response Accelerations (55, 51) 3. Site Glass 4. Spectral Response Coefficients (SDS, WI) 5. Seismic Design Category b. Basic Seismic -Force -Resisting System f psf (50 psf office + 15 psf partition) psf psf psf 89.1 mph ASD (115 mph ULT) 1.0 ASD (n/a ULT) G 1. Design Base Shear 8. Seismic Response Coefficient (Cseq) 9. Response Modification Factor (R) 10. Analysis Procedure 1.0 0338, 0.084 D 0.344, 0.134 G Light frame wood walls sheathed with structural wood panels rated for shear resistance 2,925 Ib 0.0582 65 Sknplitled NOTES: I. All items in general notes ore applicable to entire set of structural construction documents, unless noted otherwise (U.N.O.). 2. All materials and installation procedures shall conform to the Building Code. All structural elements specified as being fabricated by a particular Manufacturer shall be as indicated, unless approved equal is accepted in writing by the Structural Engineer. {"here discrepancies occur between Manufacturer's standard details and the structural details, the structural details shall take precedence. 3. Construction documents shall not be scaled for determination of quantities, dimensions, or locations. 4. Connections of mechanical, electrical and plumbing elements to structure shall be by others. 5. Where publications are referred to herein, the latest edition shall be used. 6. Structural elements shall not be cut, coped, notched, drilled, etc., unless specifically permitted by Structural Engineer, or as permitted in the Manufacturer's catalogue. 1. Structural Engineer shall be contacted when openings In structural elements are larger than the stud, joist, or bar spacing. 8. My discrepancies between the structural construction documents and the construction documents of any other discipline shall be reported immediately to both parties. 9. All special inspections shall be as required by the Building Code. 10. All materials testing shall be as required by the Building Code and in the architectural specifications. II. All corners ore 90 -degrees. 12. All construction testing reports and installation logs shall be provided to the Structural Engineer within 1 dais of testing or installation. 13. The structural drawings indicate the structural elements in their final positions. The Contractor shall provide adequate temporary shoring and bracing as required to achieve the completed structure. The Contractor shall retain a Structural Engineer to design any temporary shoring or bracing that is required. 14. Basement and retaining walls shall be backfilled only after all supporting roof framing, floor framing, and/or slabs have been installed. Alternately, adequate temporary shoring maj be used. Type of backfill shall be verifled with the Structural Engineer and the Geotechnical Engineer before backfilling begins. 15. All existing structural elements, dimensions and elevations shall be field verified before construction begins. My discrepancies between the structural construction documents and the existing conditions shall be reported immediately to the Structural Engineer before proceeding. CONNECTORS/FASTENERS/ADHESIVE5/WELDIN6/GROUT: I. All nailing of wood members shall be as indicated in the Fastener Schedule of the Building Code. All nails shall be cannon type. All nails shall have dimensions as specified in the National Design Specification for Wood Construction. All nails shall conform to ASTM FI661. 2. All wood screws shall have dimensions as specified in the National Design Specification for Wood Construction. All wood screws shall conform to ANSI/ASME 518.6.1. All wood screws shall have minimum penetration of 10 diameters into base material. All wood screws shall be Installed in pre -bored holes. 3. All lag screws shall have dimensions as specified in National Design Specification for Wood Construction. All lag screws shall conform to ANSI/ASME 518.2.1. All lag screws shall have minimum penetration of 4 diameters into base material. All lag screws shall have a washer at the head. All lag screws shall be installed in pre -bored holes. 4. All bolts shall conform to ASTM A325, except thru-bolts for wood connections which shall conform to ASTM A301. All bolts in steel connections shall have a washer at the nut. All bolts in wood connections shall have a washer at both the head and the nut. 5. All anchor bolts shall conform to ASTMFI554, Tade 36. All anchor bolts shall be placed using setting templates. b. All drive pins shall be Hilti X -DNI. Drive pins shall have 15' minimum penetration into concrete base material, and shall penetrate completely through steel base material, but need not exceed 1/2" embedment. 1. All pre -fabricated steel connectors shall be as manufactured by Simpson. All pre-fctricated steel connectors shall use maximum size and quantity of fasteners Indicated in the Manufacturer's catalogue. All pre -fabricated steel connectors in contact with treated wood shall be galvanized as recommended in the Manufacturer's catalogue. 8. All fasteners that are exposed to earth or weather, or are in treated wood, shall be galvanized. 9. All glue For structural wood panels for floors shall conform to ASTM D3448. 10. All non -shrink grout shall be non-metallic with a minimum allowable compressive strength of 5 900 psi. II. Gypsum wallboard shall conform to ASTM G36. 12. All fasteners to concrete or CMU shall be as follows with standard errbedments as specified in the Manufacturer's catalogue. Fasteners shall be installed in accordance with all Manufacturer's recomendations and specifications. Expansion Hilti Kwik Bolt 3 Capsule Hilti HVA + HAS -E STD rod Adhesive Hilti HIT HYI50 MAX + HAS -E STD rod Screen Hilti HIT HYTO + ASTM A301 threaded rod Epoxy Hilti HIT RE500 + HAS -E STD rod SHOP DRAWINGS: I. Supplier shall furnish one reproducible and three copies (or one electronic copy) of shop drawings of the following structural elements: reinforcing steel, structural steel, pre-engineered plated wood trusses, and engineered wood products. 2. Supplier shall provide four copies (or one electronic copy) of all mix designs. 3. Structural calculations shall be included for pre-engineered elements, and shall be stamped by a Structural Engineer with a valid license in the jurisdiction of the project. 4. All items listed herein shall be provided to the Structural Engineer prior to fabrication, which shall not begin until review has been completed. 5. Shop drawings shall not contain reproductions of the construction documents. b. Shop drawings shall be reviewed and initialed by the Contractor prior to submitting them to the Structural Engineer. 1. Variations from the construction documents requested by the Supplier or Contractor shall be clearly noted on the shop drawings. 8. Shop drawing review by the Structural Engineer is only for general conformance with the structural design requirements. Structural Engineer is not responsble for omissions, quantities, or dimensions. Structural Engineer is not responsible for fabrication methods or construction tectniques. Contractor is responsble for conforming to the contract documents. FOUNDATION: I. Refer to geotechnical report *113 459A by HP Geotech dated 2013-12-18. 2. All soil conditions shall be verified by the Geotechnical Engineer during excavation. 3. All recommendations for subgrade preparation under foundation elements shall be Followed as specified in the geotechnical report. 4. All ASSUMED values noted herein shall be verified by the Geotechnical Engineer during excavation, and issued to the Structural Engineer in a written report prior to construction. 5. All earth -retaining structures have been designed according to the following ASSUMED values: At -rest Equivalent Fluid Pressure 60 pcf Active Equivalent Fluid Pressure 40 pd Passive Equivalent Fluid Pressure 240 pcf Coefficient of Sliding Friction 025 b. Provide adequate drainage behind all earth -retaining structures such that hydrostatic pressure does not occur. Earth retaining structures are not designed to resist hydrostatic pressure. 1. Concrete for foundations and slabs shall not be placed on frozen or saturated material. 8. All footings have been designed according to the following ASSUMED values: Maximum allowable bearing pressure (tall) 1,500 psf Minimum allowable dead load bearing pressure (qdl) 0 psf 9. All footings shall be Founded on undisturbed native material or compacted structural fill below frost depth as specified in the geotechnical report. CAST -IN-PLACE CONCRETE: I. All cast -In-place concrete has been designed according to Building Code Requirements for Reinforced Concrete (AGI 318). 2. All aspects of cast -in-place concrete construction shall be in conformance with the AGI Manual of Concrete Practice. 3. All concrete shall have minimum 28 -day compressive strengths as follows: Footings, Walls, 3,OOpsi Slabs -on -Grade 3,500 psi Slabs -on -Void 41300 psi 4. All concrete shall use Type I cement, except concrete exposed directly to soil shall use Type II cement. 5. All concrete mix designs shall be formulated such that a minorum of 10% and a maximum of 40% of the portland cement is replaced by fly ash, except all slabs shall have a maximum of 20% fly ash. 6. Contractor shall notify Structural Engineer of location of all construction joints prior to concrete pincement. Construction joints shall be prepared by roughening then cleaning the surface of the concrete leaving no loose particles or damaged concrete. Horizontal joints shall not be allowed unless specifically indicated on the construction documents. 1. All exposed edges and corners of concrete shall be chamfered 3/4'. 8. All vertical faces of concrete shall be formed, except drilled piers. 9. All concrete shall be finished as indicated on the architectural drawings. REINFORCING STEEL: I. All aspects of concrete reinforcing construction shall be in conformance with the AGI Manual of Concrete Practice. 2. All reinforcing steel shall conform to ASTM A615-19 and shall be grade 60. 3. All welded wire fabric (Hit) shall conform to ASTM A-185. 4. All splices in reinforcing steel shall be 48 bar diameters. Provide corner bars at every corner. All welded wire fabric shall be kipped and tied one full panel. 5. Reinforcing steel shall not be re-bent without approval by the Structural Engineer. 6. Reinforcing steel shall not be welded without approval by the Structural Engineer. 1. All reinforcing steel in slabs shall be placed using chairs. 8. All rebar shall have minimum cover as follows: Gast against soil 3" Gast against form, and exposed to soil or weather 1.5" Cast against form, and not exposed to soil or weather 0.15" WOOD: I. All wood has been designed according to NDS National Design Specification for Wood Construction. 2. All wood shall be Doug -Fir graded as follows: Studs, built-up posts, blocking, braces Stud grade 4x and larger members No. I All other No. 2 3. All wood members composed of multiple elements shall be glued and nailed together. 4. All wood columns/posts shall be continuous down to the foundation or to a transfer bean. Joists spaces under posts/columns shall have solid blocking. Blocking shall be of equal or larger size of the column/post. 5. All wood that is In contact with concrete or masonry, or that is exposed to earth or weather shall be pressure -treated. b. All treated wood shall be AGO 0.25 pcf, except where in contact with soil or standing water it shall be AGO 0.40 pcf. 1. All wood posts built-up from multiple studs shall be constructed in accordance with NDS National Design Specification for Wood Construction section 1533. 8. All wood members for roofs with snow load have been designed with a duration of load factor (GD) of 1.15. All wood members for walls with wind load have been designed with a duration of load factor (CD) of 1.6. 9. All composite wood decking shall be as manufactured by Evergrain. All composite wood decking shall be designed for the spans and loads as indicated on the drawings. ENGINEERED WOOD: !. All engineered wood has been designed according to NDS Manual for Engineered Wood Construction. 2. All laminated veneer lumber (LVL) shall be Microilam as manufactured by Weyerhaeuser. 3. All laminated strand lumber (L5L) rim board and studs shall be TlmberStrand 1.3E as manufactured by Weyerhaeuser. 4. All laminated strand lumber (LSL) beans and headers shall be Timber -Strand 155E as manufactured by Weyerhaeuser. 5. All 1 -joists shall be series indicated on plan as manufactured by Weyerhaeuser. b. All structural wood panels shall conform to all APA specifications. 1. All composite wood decking shall be as manufactured by [Evergrainl. All composite wood decking shall be designed for the spans and loads as indicated on the cinawings. 8. All engineered wood that is in contact with concrete or masonry, or that is exposed to earth or weather shall be Wolmanized. 9. All aspects of engineered wood costuction shall be in accordance with all of the Supplier's specifications and recommendations. 10. All engineered wood shall be designed for maximum deflections as follows: Load Roof Floor Total L/240 L/240 Live L/360 L/480 FINISHED GRADE, SEE CIVIL DHSS III= III=1 1-III111- 1 1/2' GLR TYP WOOD COLUMN, SEE PLAN SIMPSON ABA66Z WITH 5/8'4' EXP. ANCHOR 12"0 CONCRETE PEDESTAL WITH (4)1+4 VERT. AND #3 TIES (TdBSM) #4x2-b'Vx8"H DOWELS AT EACH VERT. BAR T.O. FOOTING SEE PLAN w EQ. / / SEE SC EQ. -IEDULE / SECTION REINFORCE PER SCHEDULE TYPICAL EXTERIOR HOOD COLUMN TO CONCRETE PEDESTAL TO CONCRETE FOOTING CONNECTION 3/4"=1'-O T.O. CONCRETE (OR CMU) SEE PLAN ALL OTHER FRAMN6 NOT SHOWN FOR CLARITY NGHOR BOLT (DIAMETER = 4)) ELEVATION TYPICAL ANCHOR BOLT IN CONCRETE (OR CMU) 3/4"=1'-0 STONE, SEE ARCH. DHSS FINI3IIED GRADE, SEE CIVIL DHSS -111-III-11 =III=III-III 1=111=111=11 E111-111---7-7111:- - en 4 O. a If 4" WOOD COLUMN, SEE PLAN SIMPSON ABU88Z WITH (2)5/8'0 EXP. ANCHOR EXTERIOR STRUCTURAL SLAB, SEE PLAN T.O. PILASTER SEE PLAN T.O. 5 SEE PLAN #4x2'-4" DOWELS; MATCH SPACING OF SLAB BARS; DRILL 4" INTO EXISTING AND SET IN EPDXY (4)#5 VERT. WITH *3 TIES 12'oc ALL HORIZONTAL HALL REINFORCING SHALL BE CONTINUOUS THRU PILASTER T.O. LEDGE GCC ARCH. OHM -(2) *5 VERT. ADDITIONAL TYPICAL PILASTER #4x2'-611/x8"H DOWELS AT EACH VERT. BAR T.O. FOOTING SEE PLAN 3/4"=1'-0 FOUNDATION WALL TOP REINF SEE APPLICABLE SECTION n a d 4 4 BENT BARS; MATCH SIZE AND QUANTITY OF TOP BARS (DIAMETER =a4) d a 44 a d e a a a4 e a a d 4 ad a d a 48x$,TYP.ae a n / / d d G a C 4 a a / a d 4 4 e a 4\ J a 4 Fl FVATION ALL OTHER REINFORCING NOT SHOWN FOR CLARITY TYPICAL REINFORCING AT STEP IN TOP OF FOUNDATION NALL (BOTTOM OF HALL 15 SIMILAR) O. 3/4"=11-0 �I- I I -III 2,=111 -111 --III- - I I -I I I-11 kT111E111: GOLUMN/FOOTING a • a 4 ore • o 4a e a a e. T.O. (E) SHEATHING} SEE PLAN q WOOD BEAM, SEE PLAN (NEW OR EXISTING) SIMPSON GGQ6b5DS2.5 WOOD COLUMN, SEE PLAN SIMPSON ABA66Z WITH 5/8"4) EXP. ABHOR T.O. FOOTING err-Ft,- t_I 111---iE. PLAN. Y III-IIHI X111-111- EQ. EQ. SEE SGEDULE ELEVATION REINFORCE PER SCHEDULE TYPICAL HOOD BEAM TO HOOD COLUMN TO CONCRETE FOOTING ‘;-CONNECTION O. 3/4"=11-0 MIMIC Struck 259031s -HANGER SEE PLAN Boulder 303 495 f www. i =stn ral, inc. ngineering Studio et olorado 80301 06 V 303 495 5276 f ctural.com HOOD BEAM, SEE PLAN SIMPSON LPG4Z WOOD COLUMN, SEE PLAN PI F,/ATIMI 3/4"=1'-0 11111=111 =111=11 H 11 11 1I-111; 2,17.2.C.) WOOD COLUMN, SEE PLAN SIMPSON ABA44Z WITH I/2"4) EXP. ANCHOR 12"4) CONCRETE PEDESTAL WITH (4)*4 VERT. AND *3 TIES (TdB*M) #4x2-6"Vx8"H DOWELS AT EACH VERT. BAR T.O. FOOTING SEE PLAN SECTION REINFORCE PER SCHEDULE TYPICAL INTERIOR HOOD COLUMN TO CONCRETE PEDESTAL TO 6 CONCRETE FOOTING CONNECTION 11 PLAN WOOD BEAM, SEE PLAN WOOD BEAM, SEE PLAN HANGER, SEE PLAN ; ' ®®1 y N i fiel[�I, I _ N1 N \I x Lim -1 = J I 1 !. m PLAN " LAG SCREWS A5 SHOWN (4" MIN. EMBED) HOOD COLUMN, SEE PLAN 3/4"=1'-O ELEVATION I 3/4" k PLAN HOOD BEAM, SEE PLAN, MI I tR CORNER 1' LAG SCREWS AS SHOWN (4" MIN. EMBED) WOOD COLUMN, GEE PLAN 3/4:1-0 RIWISIONS APPROVED DATE: ( III rI f `IO BY: FZ%►' NOTE: These drawing revisions must accompany the previously approved set of plans at job site for Building Inspector's reference. 7/ 13/5 )/4" SOUTH ELEVATION THRU BOLTS AS SHOWN 6X10 TOP CHORD 6Th WEB WOOD POST, SEE PLAN WOOD BEAM, SEE PLAN LAG SCREWS A5 SHOWN (4" MIN. EMBED.), TYP. WOOD COLUMN, SEE PLAN Oy 3/4"=1'-0 w 0 0 2 w w U_ LL 0 0 0 0 Q >- L.L F - z w ASPEN EQUESTRIAN ESTATES SUBDIVISION GARFIELD COUNTY, COLORADO 7 PM, AutoCAD PDF (General Documentation).pc3 P:12019\19054Aspen Equestrian Office Remodel-Addition\Structural\2020-10-26 construction\19054 S1.dwg, 10/25/2020 7 0 0 6'-7 316" 51-4 7/8" 13'-4" 4'-0" — ane I I pr L --J F2.5 T.O. (E) SHEATHING =100'-0" r-- i 160 Sice I � I L --J F2.5 -J IN 13'-b 3/5° 5'-4 1/4" N N IP -0" L= F2.O N N N N T.O. (E) CIEATHING i AL, tuI (E) ,F2.5 (E) (E) 55 FLUSH (E) 5.5X126L FLUSH 7'-3" coo I (E) 5.5X12GL X25— J O N FLUSH H (E) 2X12 24°oc T.O. (E) GRADE N =qt -8" THIS ARENA N N N N N f 7'-O" '3)1.75X11.25LVL (E) 5.5X13.5GL $T.O. (E) SHEA-HIN6 Y =100'-0" '3)1.75A125LVL F3.0 12-b' e(2)2x12 —FLUSH - (3)1.-5XII25LVL (3)I I' -O" 1E) 55XI3.`SGL 5XII.25LV r 2 -0" T 15-4 5/16" EXTERIOR STRUCTURAL SLAB U1 O 16'-6" SLOPE I "/FT 2 9 2 1 ntegral, inc. Structural Engineering Studio 2590 31st Street Boulder Colorado 80301 303 495 5206 v 303 495 5276 f www.i2structural.com CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS, AND STRUCTURAL ELEMENTS BEFORE CONSTRUCTION BEGINS. N Z Z Z F- F_ 0 1-- 0 0 '-0E--OU V CrI. CC W W W W Z O- ONc-O r -rOON : - N N ti • O O cD LL "t- 0 0 0 r d1~�p)0000 D o0 0 0 0 0 p c N N N • N N Z CD v N o 0 CD 0 SPREAD FOOTING SCHEDULE TYPE FOOTING SIZE REINFORCING STEEL WIDTH LENGTH THICKNESS F2.0 2-0" 2-O" 12" (3) 44 E.W. F25 2'-6" 2'-6" 12" (3) #4 E.W. F3.0 3'-0" 3'-0° 12" (3) #4 E.W. r 0 N r N 0 CO EL 0 0 CO 0 N 0 0 m co - 5 n 0 N 0 CO N PLAN NOTES: I. EXTERIOR STRUCTURAL SLAB CONSTRUCTION: 6" AIR -ENTRAINED CONCRETE SLAB OVER 6" FORMED VOID OVER COMPACTED STRUCTURAL FILL (SEE GEOTECHNICAL REPORT). REINFORCE SLAB WITH EPDXY-COATED #4 ® IS"oc E.W. AT MID -DEPTH. PROVIDE (2) #4x4'-0" DIAGONAL IN SLAB AT ALL RE-ENTRANT CORNERS. PROVIDE NO CONTROL JOINTS. 2. TOP OF NEW FOOTING ELEVATION = q2-8", UNLESS NOTED OTHERWISE THUS: T.O. FOOTING=ELEVATION 3. TOP OF NEW FOUNDATION WALL ELEVATION NOTED THUS: T.O. WALL=ELEVATION 4. TOP OF EXTERIOR SLAB ELEVATION NOTED TI -US: T.O. SLAB=ELEVATION 5. TOP OF SLAB SLOPES LINEARLY BETWEEN SPOT ELEVATIONS. 6. SEE SHEET 50.1 FOR GENERAL NOTES AND TYPICAL DETAILS. 7. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS. S. ALL FOUNDATION ELEMENTS ARE CENTERED ON WALLS AND COLUMNS, UNLESS NOTED OTHERWISE. q. NEW I EXISTING FLOOR CONSTRUCTION: 23/32" APA RATED STURD-I-FLOOR (24°oc, EXP. I, TIG) OVER JOISTS AS SHOWN. ATTACH STURD-I-FLOOR TO SUPPORTS WITH GLUE AND IOd 0 6"oc AT PANEL EDGES AND 12"oc ATINTERMEDIATESUPPORTS. 10. TOP OF SHEATHING ELEVATION NO1 tU TRIS: T.O. SHEATHING=ELEVATION II. SEE SHEET 50.1 FOR GENERAL NOTES AND TYPICAL DETAILS. 12. SEE ARCHITECTURAL DRAWINGS AND FOUNDATION PLAN FOR ADDITIONAL DIMENSIONS. 13. ALL COLUMNS, POSTS, AND WALLS SHOWN ARE BELOW, UNLESS NOTED OTHERWISE. 14. ALL FLOOR BEAMS ARE DROPPED, UNLESS NOTED OTHERWISE. Q 15. EXISTING EXTERIOR I ARENA HALL CONSTRUCTION: 2X6 STUDS 0 16°oc WITH (I) 2X6 BOTTOM rn PLATE AND (2) 2X6 TOP PLATES. 7/16" APA RATED SHEATHING (24/16, EXP. I) ON EXTERIOR FACE ATTACHED WITH 8d ® 6"oc AT PANEL EDGES AND 12"oc AT INTERMEDIATE SUPPORTS. I/2" GYPSUM WALLBOARD ON INTERIOR FACE ATTACHED WITH 16x1.25" TYPE W OR 5 SCREWS ® 8"0c AT PANEL EDGES AND 12"0c IN THE FIELD. BLOCK ALL PLYWOOD/05B PANEL EDGES. lb. EXISTING EXTERIOR I ARENA HALL OPENING CONSTRUCTION: (2) 2X10 HEADER (UNLESS NOTED OTHERWISE) NTH INSULATION (SEE ARCHITECTURAL DRAWINGS) BETWEEN PLIES. (I) 2X6 SILL (WHERE APPLICABLE). (2) 2X6 KINGSTUDS + (I) 2X6 TRIMSTUD, UNLESS NOTED OTHERWISE. HEADERS SHALL NOT BE CONTINUOUS OVER INTERMEDIATE POSTS, UNLESS SPECIFICALLY INDICATED ON THE PLAN. Il. EXISTING INTERIOR BEARING WALL CONSTRUCTION: 2X4 STUDS 0 16"oc WITH (I) 2X4 BOTTOM PLATE AND (2) 2X4 TOP PLATES. I/2" GYPSUM WALLBOARD ON BOTH FACES ATTACHED WITH *bx1.25' TYPE WOR 5 SCREWS 0 Floe AT PANEL EDGES AND 12"oc IN THE FIELD. 18. EXISTING INTERIOR BEARING WALL OPENING CONSTRUCTION: (2) 2X10 HEADER (UNLESS NOTED OTHERWISE) WITH 7/16" APA RATED SHEATHING (24/16, EXP. I) FILLER PIECE BETWEEN PLIES. (I) 2X4 KINGSTUD + (I) 2X4 TRIMSTUD, UNLESS NOTED OTHERWISE. HEADERS SHALL NOT BE CONTINUOUS OVER INTERMEDIATE POSTS, UNLESS SPECIFICALLY INDICATED ON THE PLAN. Iq. EXISITNG FOUNDATION HALLS 8"W X 36"H. 20. EXISITNG FOOTINGS 16"W X 8"H. 21. DECK CONSTRUCTION: 15" COMPOSITE DECKING OVER 2X12 0 I6"oc, UNLESS NOTED OTHERWISE. ATTACH DECKING TO SUPPORTS WITH (2) *5x2.5° COMPOSITE WOOD SCREWS AT THE END OF EACH PIECE AND AT ALL INTERMEDIATE SUPPORTS. IS' q 5/16" 1 1 O N HANGER SCHEDULE MARK HANGER HUC212-2 NOTES OUNDATIO�4 MAIN LEVEL FRAMING PLAN i 2'-O" I/4"=1' -O" 0 m 0 LJ emN z 0) C) 0 0 — Hc) ifE o WOf Q w z Z W Q UO U E o LZUJ D LLL O 0 Ct Z C9 W 0 S J 1 n hxl, 1 M TO (2)SIMPSON '1 LOGS .2 1 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS, AND STRUCTURAL ELEMENTS BEFORE CONSTRUCTION BEGINS. L_J ntegral, inc. Structural Engineering Studio 2590 31st Street Boulder Colorado 80301 303 495 5206 v 303 495 5276 f www. i2structural. com PLAN NOTES: I. NEW d EXISTING FLOOR CONSTRUCTION: 23/32' APA RATED STURD-I-FLOOR (24"oc, EXP. I, TiG) OVER JOISTS AS SHOWN. ATTACH STURD-I-FLOOR TO SUPPORTS WITH GLUE AND 10d ® b"oc AT PANEL EDGES AND 12"oc AT INTERMEDIATE SUPPORTS. 2. TOP OF SHEATHING ELEVATION NOTED THUS: T.O. SHEATHING=ELEVATION 3, SCE SHEET 50.1 FOR GENERAL NOTES AND TYPICAL DETAILS. 4. SEE ARCHITECTURAL DRAWINGS AND FOUNDATION PLAN FOR ADDITIONAL DIMENSIONS. 5. ALL COLUMNS, POSTS, AND WALLS SHOWN ARE BELOW, UNLESS NOTED OTHERWISE. b. ALL FLOOR BEAMS ARE FLUSH, UNLESS NOTED OTHERWISE. 1. AT ALL BEAM BEARING LOCATIONS, PROVIDE STUD PACK EQUAL TO OR EXCEEDING BEAM WIDTH, UNLESS NO1tD OTHERWISE b. ROOF CONSTRUCTION: 15/32' APA RATED SHEATHING (32/16, EXP. I) OVER 2X8 ® 24"oc. ATTACH SHEATHING TO SUPPORTS WITH Sd @ b"oc AT PANEL EDGES AND 12'oc AT INTERMEDIATE SUPPORTS. 4. SEE ARCHITECTURAL DRAWINGS FOR ROOF SLOPES, HEEL HEIGHTS, OVERHANG LENGTHS, AND TOP OF WALL PLATE ELEVATIONS. 10. ALL ROOF BEAMS ARE DROPPED, UNLESS NOTED OTHERWISE. II. EXISTING EXTERIOR 4 ARENA WALL CONSTRUCTION 2X6 STUDS ® I6"oc WITH (I) 2X6 BOTTOM PLATE AND (2) 2X6 TOP PLATES. 1/1b" APA RATED SHEATHING (24/16, EXP. I) ON EXTERIOR FACE ATTACHED WITH Sd ® 6"oc AT PANEL EDGES AND IToc AT INTERMEDIATE SUPPORTS. 1/2" GYPSUM WALLBOARD ON INTERIOR FADE ATTACHED WITH *6x1.25' TYPE W OR 5 SCREWS 0 S'oc AT PANEL EDGES AND 12"oc IN THE FIELD. BLOCK ALL PLYWOOD/OSB PANEL EDGES. 12. EXISTING EXTERIOR 4 ARENA WALL OPENING CONSTRUCTION: (2) 2X4 HEADER (UNLECO NOTED OTHERWISE) WITH INSULATION (SEE ARCHITECTURAL DRAWINGS) BETWEEN PLIES. (I) 2X6 SILL (WHERE APPLICABLE). (2) 2X6 KINGSTUDS + (I) 2X6 TRIMSTUD, UNLESS NOTED OTHERWISE. HEADERS SHALL NOT BE CONTINUOUS OVER INTERMEDIATE POSTS, UNLESS SPECIFICALLY INDICATED ON THE PLAN. 13. EXISTING INTERIOR BEARING WALL CONSIRIUCTION: 2X4 STUDS 0 I6"oc WITH (I) 2X4 BOTTOM PLATE AND (2) 2X4 TOP PLATES. 1/2' GYPSUM WALLBOARD ON BOTH FACES ATTACHED WITH N6x125° TYPE W OR 5 SCREWS 0 8"oc AT PANEL EDGES AND 12'oc IN THE FIELD. 14. EXISTING INTERIOR BEARING WALL OPENING CONSTRUCTION: (2) 2X4 HEADER (UNLESS NOTED OTHERWISE) WITH 1/16' APA RATED SHEATHING (24/16, EXP. I) FILLER PIECE BETWEEN PLIES. (2) 2X4 KINGST11D + (2) 2X4 TRIMSTUD, UNLESS NOTED OTHERWISE. HEADERS SHALL NOT BE CONTINUOUS OVER INTERMEDIATE POSTS, UNLESS SPECIFICALLY INDICATED ON THE PLAN. HANGER SCHEDULE MARK HANGER NOTES Q I16212-2TE -- 0 HUG212-2 Q3 SUR/L2S-2 INVERTED ® 111628-2 -- 5 GJT6Z -- "'PER LEVEL FRAM I NC PLAN 1/4'=11-0" H r N Z Z I-0I—O Z 1— U W WWW Z U O O N r CO • r 0 0 r NNIS-O)O X 0 0 0 O O O O O � N N N N 0 0 0 0 0 N N N CV m 0 cim o N Zr- Cl I. a V) 0 0 W� C" H a Q 0 C QV o 0 0� 0 U W0 i QL 3 0 ci0 t N N U �/ gC� � 0 0 N OFFICE REMODEL / z 0 H 0 0 Q >- L.L H z w ASPEN EQUESTRIAN ESTATES SUBDIVISION GARFIELD COUNTY, COLORADO PM, AutoCAD PDF (General Documentation).pc3 uction\19054 51.tlwg, 10/25/2020 1: -r (E) PEMB BEAM T 0 (E) S" Z-6IRT5 ® 5'-b"oc Q 2 2 (E) T.O PEMB FRAME AT THIS GRID = 109'-2" 0 it ■ ■ / i / (E) 2X12 g 24"oc (V N 2 n (E) OVERFRAMING / W 2 I \ P Z9 (E) OVERFRAMING (E) T.O PENIS FRAME AT THIS GRID = 104'-2" 1 (E) PEMB BEAM 9 v (2)'X i h X n 0 N / V ci 2 6XI2 is CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS, AND STRUCTURAL ELEMENTS BEFORE CONSTRUCTION BEGINS. ntegral, inc. Structural Engineering Studio 2590 31st Street Boulder Colorado 80301 303 495 5206 v 303 495 5276 f www.2structural. corn PLAN NOTES: I. EXISTING ROOF CONSTRUCTION: 15/32" APA RATED SI IEATHING (32/16, EXP. I) OVER JOISTS A5 SHOWN. ATTACH 54ILATHING TO SUPPORTS WITH 8d a b"oc AT PANEL EDGES AND 12"oc AT INTERMEDIATE SUPPORTS. 2. SEE SHEET 50.1 FOR GENERAL NOTES AND TYPICAL DETAILS. 3. SEE ARCHITECTURAL DRAWINGS AND FOUNDATION PLAN FOR ADDITIONAL DIMENSIONS. 4. ALL COLUMNS, POSTS, AND WALLS SHOWN ARE BELOW, UNLESS NOTED OTHERWISE, 5. SEE ARCHITECTURAL DRAWINGS FOR ROOF SLOPES, HEEL HEIGHTS, OVERHANG LENGTHS, AND TOP OF HALL PLATE ELEVATIONS. 6. ALL BEAMS ARE DROPPED, UNLESS NOTED OTHERWISE. 1. AT ALL BEAM AND GIRDER TRUSS BEARING LOCATIONS, PROVIDE STUD PACK EQUAL TO OR EXCEEDING BEAM WIDTH, UNLESS NOTED OTHERWISE. S. EXISTING EXTERIOR WALL CONSTRUCTION: 2X6 STUDS a Ib"oc WITH (I) 2X6 BOTTOM PLATE AND (2) 2X6 TOP PLATES. 1/16" APA RATED SHEATHING (24/16, EXP. 1) ON EXTERIOR FADE ATTACHED WITH 8d a 6"oc AT PANEL EDGES AND 12"oc AT INTERMEDIATE SUPPORTS. 1/2" GYPSUM WALLBOARD ON INTERIOR FADE ATTACHED WITH #6x125" TYPE W OR 5 SCREWS a 8"oc AT PANEL EDGES AND 12"oc IN THE FIELD. BLOCK ALL PLYWOOD/OSB PANEL EDGES. 4. EXISTING EXTERIOR WALL OPENING CONSTRUCTION: (2) 2X4 HEADER (UNLESS NOTED OTHERWISE) WITH INSULATION (SEE ARCHITECTURAL DRAWINGS) BETWEEN PLIES. (I) 2X6 SILL (WHERE APPLICABLE). (2) 2X6 KINGSTUDS + (I) 2X6 TRIMSTUD, UNLESS NOTED OTHERWISE. HEADERS SHALL NOT BE CONTINUOUS OVER INTERMEDIATE POSTS, UNLESS SPECIFICALLY INDICAItll ON THE PLAN. 10. EXTERIOR WALL OPENING CONSTRUCTION: (2) 2X4 HEADER (UNLESS NOTED OTHERWISE) WITH INSULATION (SEE ARCHITECTURAL DRAWINGS) BETWEEN PLIES. (I) 2X6 SILL (WHERE APPLICABLE). (2) 2X6 KINGSTUDS + (I) 2X6 TRIMSTUD, UNLESS NOTED OTHERWISE. HEADERS SHALL NOT BE CONTINUOUS OVER INTERMEDIATE POSTS, UNLESS SPECIFICALLY INDICATED ON THE PLAN. II. EXISTING INTERIOR BEARING WALL CONSIRUCTION: 2X6 STUDS a Ib"oc WITH (I) 2X6 BOTTOM PLATE AND (2) 2X4 TOP PLATES. I/2" GYPSUM WALLBOARD ON BOTH FACES ATTACHED NTH #6x125" TYPE W OR S SCREWS a 8"oc AT PANEL EDGES AND 12'oc IN THE FIELD. 12. EXTERIOR WALL CONSTRUCTION: 2X6 STUDS a lb"ac WITH (I) 2X6 BOTTOM PLATE AND (2) 2X6 TOP PLATES. 1/16" APA RATED SHEATHING (24/16, EXP. I) ON EXTERIOR FACE ATTACHED 111TH 8d I b"oc AT PANEL EDGES AND 12"oc AT INTERMEDIATE SUPPORTS. 1/2" GYPSUM WALLBOARD ON INTERIOR FADE ATTACHED WITH 116x125" TYPE W OR 5 SCREWS a 8"oc AT PANEL EDGES AND 12"oc IN THE FIELD. BLOCK ALL PLYWOOD/OSB PANEL EDGES. 13. ROOF CONSTRUCTION: 15/32" APA RATED SHEATHING (32/16, EXP. I) OVER 2X8 a 24"oc. ATTACH SHEATHING TO SUPPORTS WITH 8d a b"oc AT PANEL EDGES AND Inc AT INTERMEDIATE SUPPORTS, 14. ROOF OVERFRAMING CONSTRUCTION: ALL MAIN ROOF FRAMING AND SHEATHING SHALL BE INSTALLED BEFORE INSTALLING OVERFRAMING. 2X6 RAFTERS a 24"oc WITH 2X8 RIDGES, VALLEYS, AND HIPS WHERE REQUIRED. 2X10 FLAT AT PERIMETER. PROVIDE 2X4 POSTS DOWN TO MAIN ROOF AT 48"oc ALONG EACH MAIN ROOF MEMBER STAGGERING LOCATIONS WITH ADJACENT MEMBERS. SHEATHING AND ITS ATTACHMENT SHALL MATCH MAIN ROOF. ALTERNATE OVERFRAMING MAY BE PROVIDED BY USING PRE-ENGINEERED PLATED ROOF TRUSSES, OR MAIN ROOF TRUSSES MAY BE CONFIGURED TO MEET FINAL ROOF PLANES. ROOF FRAMING PLAN I/4"=1' -O" 14_ II J x ¢l N I -OH - O W W W W d OCC d w O N r r rO O O !!) C7 N rn r r r .15 N N t -o O O O p c N N N CV Z O a ai 0 U 0 r r 0 N 1 Q C) 0 M a 0 0 co 0 L 0 L 0 N r 0 03 N J 0 02 w U- 0 ASPEN EQUESTRIAN ESTATES SUBDIVISION GARFIELD COUNTY; COLORADO S1.3 1-1 I I-111-1 =111=111=111- 1=111=111=1 11 =1 I 1=1 I i-1 I Iz 4' STONE VENEER, SEE ARCH. DW65 FINISH ILD GRADE, SEE CIVIL DWGS to EXTERIOR STRUCTURAL SLAB, SEE PLA if - T.O. SLAB 5"1 1-111—(11—i 1 =111�11 E111- 1=1�I=1T1-1� =111=11 I=111 - •'a a • SEE PLAN #4x2'-b"x2'-b" DOWELS IS"oc *5 @ IS"oc E.W. GNTRD; VERT. BARS BENT A5 SHOWN • a • a a U 3/4'=1'-0 4" STONE VENEER, SEE ARCH. DHSS FINISHED GRADE, SEE CIVIL DWG5 L4X44" CONT. WITH EXP. ANCHORS 0 Ib"oc I'-0" T.O. LEDGE At SEE ARCH. DW (I)#5 CONT. NB (2)#5 CONT. TSB #4x2'-6"VxS"H DOWELS IS"oc H H J 111\111-11 III -11 �-I _ =111=111—I I 1111111 3/411=11-0 3/4"=1'-0 T.O. FOOTING 511 PLAN EXISTING EXTERIOR WALL CONSTRUCTION EXISTING FLOOR CONSTRUCTION T.O. 01 (LATHING. SEE PLAN q EXISTING EXTERIOR WALL CONSTRUCTION 1—I 1 I-111-11 --s—rt - 1=111=111= �=;n=1Ti-ir 111-111-111- z t EXISTING FOUNDATION HALL CONSTRUCTION EXISTING FOOTING CONSTRUCTION DECK CONSTRUCTION, SQ PLAN SIMPSON .18212 BEAM, SEE PLAN STAIRS, WHERE APPLICABLE SEE ARCHITECTURAL DRAWINGS FOR EXACT TREAD/RISER DIMENSIONS #4 CONT. AT EACH NOSING • a • . a a • • a a 'SO. SLAB,( EE PLAN PROTECTION 0 U- z O m SEE SECTION 3/52.1 FOR ADDITIONAL NOTES 4" STONE VENEER, SEE ARCH. DWG5 EX1 bRIOR STRUCTURAL SLAB, SEE PLAN f A • #4x2' -6'x2'-6' DOWELS 18"oc #5 ® 18"oc E.W. CHIRP #4x10"Hx8'V DOWELS IS"oc TSB; DRILL 4" INTO EXISTING AND SET IN EPDXY 111=11(0 -III=111=1 11- 1=1 1=1 I1=11 Eli1-111-1 I la. 4 a� • • T.O.\SLAB SEE PLAN N T.O. FOOTING SEE PLAN PROVIDE ADEQUATE FLASHING AND WATERPROOFING TO PREVENT WATER INFILTRATION AND DAMAGE EXISTING EXTERIOR WALL CONSTRUCTION EXISTING FLOOR CONSTRUCTION il A d a T.O. SHEATHING SEE PLAN EXISTING EXTERIOR WALL CONSTRUCTION (2)#5 DONT. TSB #4x2'-b"VxS"H DOWELS 18"oc A q2) 3/4'=I'-O 10 AA L111_111_11 =1I I— I I-111= 1=I I I=111=11 111-111-111- EXISTING FOUNDATION WALL CONSTRUCTION EXISTING FOOTING CONSTRUCTION DECK CONSTRUCTION, SEE PLAN BEAM, SEE PLAN 2X12 DONT. LEDGER WITH (3)#I2 SCREWS o EACH STUD (Ib"oc MAX) 4" STONE VENEER, SEE ARCH.DWGS FINISHED GRADE, SEE CIVIL DHSS L4X44" DONT. WITH I" EXP. ANCHORS 0 16"oc 2X FULL WIDTH BLOCKING BTWN STUDS EXISTING EXTERIOR WALL CONSTRUCTION l H =III=III=11 1-III=I L . EXISTING FLOOR CONSTRUCTION T.O. SI ILATHINGJ� SEE PLAN Y EXISTING EXTERIOR WALL CONSTRUCTION EXISTING FOUNDATION WALL CONSTRUCTION EXISTING FOOTING CONSTRUCTION 3/4'=I' -O 1 FINISHED GRADE, SEE CIVIL DWG5 F —111-111-1 111111111111 -1-111E111_---1 1I I-1 I-111- A 3/4"=1'-0 to 4 • EXTERIOR STRUCTURAL SLAB, SEE PLAN a d • a 8" I'-4" T.O. SLAB SEE PLAN #4x2' -6"x2'-6" DOLLS IS'oc *5 ® 18"oc E.W. GNTRD (2)#5 CONT. TSB #4x21-6"VxS'N DOWELS I8"oc 4 T.O. FOOTING 4 SEE PLAN FLOOR EDGE NAILING EXISTING FLOOR CONSTRUCTION T.O. SI ILATHING�1 SLE PLAN Y BEAM, SEE PLAN 72.1/ 3/4"=1'-O X11 �J2 . 3/4"= I' -O i2 ntegral, inc. Structural Engineering Studio 2590 31st Street Boulder Colorado 80301 303 495 5206 v 303 495 5276 f www.i2structural.com EXISTING FLOOR CONSTRUCTION T.O. SHEATHING4 SEE PLAN t 3/4"= I' -O 3/4"=I'-0 2X FULL HT BLOCKING BTWN JOISTS OVER BEAM WOOD BEAM, SEE PLAN EXISTING FLOOR CONSTRUCTION T.O. SHEATHING) SEE PLAN (E) HOOD BEAM, SEE PLAN, WITH ADDITIONAL PLY, SEE PLAN, ATTACHED WITH Ibd ® 12"oc TSB r N Z Z Z I— F- O I- O 0 :E F- ct W � W �W Z d WU O O N r CO r r O O N c4i al LL '— 0 0 0 O~ 2 0 0 0 0 0 r rN N N0 N O a �NNNNCNO Z N 0 U_a CIS I� U0) ZS _nn 2 VJ L O co ® L. Co a opt ccU Q 0 N N 4 4 m 0 M a 4 0 I~1 0 0 0 I- OJ V 0 In II) L 0 N 0 co N OFFICE REMODEL / ENTRY ADDITION ASPEN EQUESTRIAN ESTATES SUBDIVISION GARFIELD COUNTY. COLORADO 2 JOISTS ONLY ON ONE SIDE WHERE APPLICABLE EXISTING FLOOR CONSTRUCTION T.O. SHEATHING COE PLAN 3/4"=I' -O NEW FLOOR CONSTRUCTION, SEE PLAN SIMPSON LU521O OR LU521O-2 AS APPLICABLE BEAM, SEE PLAN EXISTING FLOOR CONSTRUCTION T.O. SHEATHING 111111.1.111. SEE PLAN SIMPSON LU521O BEAM, SEE PLAN 2X FULL HT BLOCKING BETWEEN JOISTS SET NEW JOISTS BETWEEN EXISTING AND BEAR ON WALL 6 EXISTING EXTERIOR WALL CONS I te..UCTION 3/4"=I'-0 ROOF CONSTRUCTION, SEE PLAN 2X FULL HT CONT. LEDGER WITH (3)SDWSx4" AT EACH STUD (16'oc MAX) 2X FULL WIDTH BLOCKING BTWN STUDS EXISTING EXTERIOR WALL CONSTRUCTION 3/4"=1'-0 ROOF CONSTRUCTION, SEE PLAN SIMPSON A35 WITH SDgx1.5" INTO BEAM 2X FULL HT BLOCKING BTWN RAFTERS BEAM, SEE PLAN 2X FULL HT CONT. RIM 3/4"=1'-0 JOISTS ONLY ON ONE SIDE WHERE APPLICABLE FLOOR EDGE NAILING EXISTING FLOOR CONSTRUCTION T.O. SHEATHINGJ� SEE PLAN q 3/4"=I' -O 3/4"=1'-0 ROOF CONSTRUCTION, PLAN BEAM, SEE PLAN NEW FLOOR CONSTRUCTION, SEE PLAN 2X FULL HT CONT. LEDGER WITH (3)SDWSx4° AT EACH STUD (I6"oc MAX) 12 BEAM, SEE PLAN STAIRS, WHERE APPLICABLE 2X FULL WIDTH BLOCKING BTWN STUDS EXISTING EXTERIOR WALL CONSTRUCTION I -I 3/4",ILO 2'-0" ROOF •NSTRUCTION, GCC PLAN SIMPSON LU528 SIMPSON A35 WITH SD4x15" INTO BEAM 2X FULL HT BLOCKING BTWN RAFTERS TOP CHORD, GCC DETAIL IO/SO.I 2X FULL HT CONT. RIM BEAM, SEE PLAN 2 3/4"=I'-0 EXISTING FLOOR CONSTRUCTION EXISTING EXTERIOR WALL CONSTRUCTION EXISTING FLOOR CONSTRUCTION T.O. SHEATHING SEE PLAN SIMPSON JB2I2A BEAM, SEE PLAN 3/4"=I'-0 NEW FLOOR CONSTRUCTION, SEE PLAN 3/4"=I' -O ROOF CONSTRUCTION, SEE PLAN 2X FULL HT CONT. LEDGER WITH (3)S2141Sx4" AT EACH STUD (Ib"oc MAX) 2X FULL WIDTH BLOCKING BETWEEN STUDS EXISTING EXTERIOR WALL CONSTRUCTION 2X FULL HT CONT. LEDGER WITH (3)SD1^Sx4" AT EACH STUD (Ib"oc MAX) 13 3/4"=1'-0 NEW FLOOR CONSTRUCTION, GCE PLAN BEAM, SEE PLAN STAIRS, WHERE APPLICABLE 3/4"=I'-0 ROOF CONSTRUCTION, SEE PLAN 2X FULL WIDTH BLOCKING BTWN STUDS EXISTING EXTERIOR WALL 2X FULL HT CONT. LEDGER WITH CONS I KUCTION (3)SDWSx4" AT EACH STUD (16"oc MAX) EXISTING FLOOR CONSTRUCTION T.O. SHEATHING. GCE PLAN EXISTING EXTERIOR WALL CONSTRUCTION 3/4"=I' -O 3/4"=I'-0 ROOF CONSTRUCTION, SEE PLAN SIMPSON A35 WITH SDgxIS" INTO BEAM (EACH RAFTER) BEAM, GCE PLAN 14 2X FULL WIDTH BLOCKING BTWN STUDS EXISTING EXTERIOR HALL CONSTRUCTION EXISTING FLOOR CONSTRUCTION T.O. SHEATHING SEE PLAN EXISTING EXTERIOR WALL CONSTRUCTION \2 3/4"=1'-O VALLEY CONDITION (HIP CONDITION SHOPAI) ROOF CONSTRUCTION, SEE PLAN SIMPSON L55J28Z BEAM, SEE PLAN 12 5 ntegral, inc. Structural Engineering Studio 2590 31st Street Boulder Colorado 80301 303 495 5206 v 303 495 5276 I www.i2structural.com 2 3/4"=1'-0 3/4"=1'-0 ROOF EDGE NAILING ROOF CONSTRUCTION, SEE PLAN 3/4"=1'-O ROOF OVERFRAMING CONSTRUCTION, SEE PLAN EXISTING ROOF CONSTRUCTION I� U EXTERIOR WALL CONSTRUCTION, SEE PLAN, EXCEPT NO WALLBOARD 2X FULL HT BLOCKING l 24"oc IN FIRST RAFTER SPACE 2X FULL HT CONT. RIM II u HERE ROOF 15 LOWER: 2X FULL HT CONT. LEDGER WITH (3)4'12 SCREWS ® EACH STUD (Vac MAX) EXISTING EXTERIOR HALL CONSTRUCTION 3/4"=1'-0 L F- W 0 O LL r 2 ch "a YN O U N a) c m 0 U 0 <- 0 0 W N z Z ~0 C W W d � O O N Ng'. t O" I` O> O O r O O O CV Cs1 CV N N N 60) Zrs r_ E VJ c W(a um) L. Co W sC QL 3c� r 0 r N t M 0 t7 a 0 0 op 0 0 N 2 In L 0 N r 0 0 w 0 0 w w U U- U- 0 0 H 0 0 Q >- LL H Z w ASPEN EQUESTRIAN ESTATES SUBDIVISION GARFIELD COUNTY, COLORADO S2.2