Loading...
HomeMy WebLinkAboutSoil Compaction Report 01.28.2021ICA Glenwood Springs 5020 County Road 154 Glenwood Springs, Phone: 970-945-7988 Kumar & Associates, Inc. Geotechnical and Materials Engineers and Environmental Scientists kumarusa.com Soil Compaction Report Test Method: ASTM D 6938 Client: MM -Eight Construction 715 Grand Avenue Glenwood Springs, CO 81601 Project: 19-7-221.52 Lot 52, Pinyon Mesa, Filing 2 Paintbrush Way Glenwood Springs, CO 81601 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%) Optimum Moisture Tolerance (%) Remark 3 1/28/21 430-20 B (D698) CL 17.5 105.9 19.0 103.9 123.7 12 98 98 -1 / 3 DP/MP 4 1/28/21 430-20 B (D698) CL 17.5 105.9 17.4 104.4 122.6 12 99 98 -1 / 3 DP/MP Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 3 Structural Fill: Under footings, 8' south of northeast corner Footing grade Troxler / 3440 / 23818 / 5/21/2020 Justin Orgill 4 Structural Fill: Under footings, 8' west of southeast corner Footing grade Troxler / 3440 / 23818 / 5/21/2020 Justin Orgill Remarks Comments Related Tests DP/MP: Density Pass / Moisture Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test # Related Test # Test Type 3 4 Soil Nuclear Gauge 4 3 Soil Nuclear Gauge This report presents opinions formed as a result of our observations of soil compaction. We have relied on the contractor to continue applying the recommended compactive effort and moisture to the fill during times when our observer is not observing operations. Tests are made of the soils only as believed necessary to calibrate our observer's judgement. Test data are not sole basis for opinions on whether the soils meets specifications. These test results only apply to the samples which were tested. The testing report shall not only be reproduced, except in full, without the written approval of Kumar and Associates, Inc. Nuclear gauge density testing performed in accordance with ASTM D6938. Page 1 of 1