Loading...
HomeMy WebLinkAboutColumn Section & Slab0' 8" 10 L-71 ri—±71. SCALE: 1" = 1' _, 0 5" 10" 2' 2" i I I I 117=:111 I I ElliE 0' 10" V V V V Slab reinforcement: 1' 0" WVVF 6x6-W1.4xW1.4 BOND BREAKER •V • , v V • V V a r' •q r • .1 V 17 V 111.111171Prilmilimijiallir" 17 v \-7 V r V V VARIES (See Footing Table) Drawing Name: COLUMN SECTION AND SLAB Drawn by: Sue Kupetian Date: January 6, 2016 File Name: PrecisionRingerColSecSlab.pdf CLEAN SAND OR PEA GRAVEL OR 0' 6" COMPACTED BACK- FILLAS PER SPECIFICATIONS L 0' 6" COLUMN SECTION AND SLAB • (Slab to be poured at a later date) How POINf eAl&INtePINa 202 North Ave„ #252 Grand Junction, CO 81501 970-248-9200 0/17 COLUMN TABLE * 1 A 2'0"x2'0" 3x3@#4 1 B 2'6"x2'6" 4x4@#4 1 C 3'0"x3'0" 4x4@#4 1 D 3'0"x3'0" 4x4@#4 1 E 2'6"x2'6" 4x4@#4 1 F 2'0"x2'0" 3x3@#4 2 A 2'0"x2'0" 3x3@#4 2 B 6'0"x6'0" 7x7@#5 2 E 6'0"x6'0" 7x7@#5 2 F 2'0"x2'0" 3x3@#4 3 A 2'0"x2'0" 3x3@#4 3 B 6'0"x6'0" 7x7@#5 3 E 6'0"x6'0" 7x7@#5 3 F 2'0"x2'0" 3x3@#4 4 A 2'0"x2'0" 3x3@#4 4 B 2'6"x2'6" 4x4@#4 4 C 3'0"x3'0" 4x4@#4 4 D 3'0"x3'0" 4x4@#4 4 E 2'6"x2'6" 4x4@#4 4 F 2'0"x2'0" 3x3@#4 Drawing Name: FOOTING TABLE Drawn by: Sue Kupelian Date: January 8, 2017 File Name: PrecisionRingerFootingTable.pdf All vertical bars in columns are # 6, 4 per column, and all column ties are # 3.Two ties area needed for each column. * Column Line/Frame Line designations refer to Precision Buildings Project No. 15 - B - 57465 -1, Sheet F1. HIGH P0IN �NGIN���ING 202 North Ave., #252 Grand Junction, CO 81501 970-248-9200 0//7