HomeMy WebLinkAboutApplication-PermitProject Address
Garfield County
Building & Planning Department
108 8th Street Suite 401
Glenwood Springs, CO 81601-
Phone: (970)945-8212 Fax: (970)384-3470
Parcel No.Subdivision Section Townsh¡p Range
1
Sfafus:
Issue Date: 9l2Ol2O1O Expires: 0311912011
2195 CR 154
GLENWOOD SPR|NGS, CO
218527100026
Owner lnformation Address Phone Cell
Mountain View Ghurch of Glenwoo¿ 2195 cR 154
glenwood spr¡ngs CO
(970)945-8328
2195 CR 154
glenwood springs CO
Contractor(s)Phone Primary Contractor
Proposed Construction / Details
remodel existing kitchen space
FEES DUE FEES PAID
lnv Total Paytype Amt Paid Amt Due
lnv # BLCO-9-10-20509
$ 345.26 Check # 2567 $345.26
$ o.oo
Required lnspections:
For rnspect¡ons "ar ' 1 (888)868-5306
lnspection IVR
Valuation:
Total Sq Feet:
$ 11,200.00
0
Building Department
copy
See Permit Record
Fee Amount
Commercial Building Fee
Plan Check Fee
Total:
$209.25
$136.01
$34s.26
2Monday, September 20, 2010
David Bartholomew
alrT Wco-7- /,\'J4ç
From:
Sent:
To:
Cc:
Subject:
David Bartholomew
Monday, June 20, 2011 12:40PM
Andy Schwaller; 'Ron Biggers'
Matt Provost; Jim Wilson
RE: Quick kitchen question
All,
I researched the activity of the permit and the following inspections were performed
4h3/ t1, Underground plumbing, passed.
411511.7 Gas piping, passed.
4/28/ It Framing, passed.
4/79 /77 lnsulation, passed.
5/3/tI Drywall, passed.
It appears they may be ready for a final inspection soon. We will require a final electrical approval and a final fire district
approval priorto performing/passing ourfinal inspection. A copy of this correspondence will be printed and inserted
into the building permit file to insure allthese requirements are met.
Ron, you may send us an e-mail confirming your approval or provide a report to the church to submit at final inspection
Whichever you choose will work for us. Thanks for your time in this concern.
Regards,
David
David Bartholomew, Plans Examiner
Garfield County Building & Planning
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Office: 970-945-8212
From: Andy Schwaller
Sent: Monday, June 20,2011 11:25 AM
To: David Bartholomew
Subject: FW: Quick kitchen question
From: Ron Biggers Imailto:ron,biggers@cogs,us]
Sent: Monday, June 20,2011 11:03 AM
To: Andy Schwaller
Subject: FW: Quick kitchen question
Andy,
This is an old email and project. Sense this email and a site visit in March I have not gotten any more calls or updates
from Vance. Do you know the status of this one out at the Mountain View Church on CR154?
970-384-6433
rinkl
Ron Biggers
Deputy Fire Marshal
Glenwood F ire Department
Lives !!!
er This email message and all attachments are for the sole use of the intended recipient(s)
and may contain confidential and privileged information. Any unauthorized review, usê, disclosure, or
distribution is prohibited. lf you are not the intended recipient, please contact the sender by reply e-
mail and destroy all copies of the original message. Content cannot be guaranteed to be secure or
error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or
contain viruses. The sender therefore does not accept liability for any errors or omissions in the
contents of this message, which arise as a result of e-mail transmission. lf verification is required,
please request a hard-copy version.
From : Andy Schwaller Imailto :aschwaller@garfield-cou nty.com]
Sent: Friday, March 18, 2011 B:45 AM
To: Ron Biggers
Subject: RE: Quick kitchen question
It seems like a reasonable request. What is a K Guard?
From: Ron Biggers Imailto:ron.biggers@cogs. us]
Sent: Thursday, March 77,LAIL 5:01 PM
To: Andy Schwaller
Subject: RE: Quick kitchen question
Andy,
ljust got offthe phone with Vance and made him aware of the items listed below as well. He is also a member of the
church and wíll pass the fire system tests and inspection needs on to the church board of directors. These inspections by
code are required to be done annually, we do not have records showing theses systems have been tested. There are also
no inspection tags on the systems.
Here you go
Kitchen
r Move light in center of room 12 inches from sprinkler head. Presently the light acts as an obstruction as it is only
about 1 inch from the head.
o lnstall escutcheons on the sprinkler heads in the room
o Purchase a K-Guard fire extinguisher and install it near the room exit that is closest to the new stove
General:
Have a test and inspection done on the fire protection systems, sprinkler and fire alarm, in the building. lf the
inspections call for repairs to either or both systems have the repairs completed on the system. ì
Ron Biggers
Deputy Fire Marshal
Glenwood Springs Fire Department
Fire Sprinklers Save Lives !!!
2
970-384-67433
Disclaimer:This email message and allattachments are forthe sole use of the intended recipient(s)and may contain
confidential and privileged information. Any unauthorized review, use, disclosure, or distribution is prohibited. lf you are
not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message.
Content cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost,
destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or
omissions in the contents of this message, which arise as a result of e-mailtransmission. lf verification is required, please
request a hard-copy version.
From: Andy Schwa ller [mailto:aschwaller@garfield-county.com]
Sent: Thursday, March 77,2AI7 4:24 PM
To: Ron Biggers
Subject: RE: Quick kitchen question
What does the list look like. Chances are we can
From: Ro n Biggers Imailto :ron. biggers@cogs.us]
Sent: Thursday, March 77,2A1-:-.2:24 PM
To: Andy Schwaller
Subject: RE: Quick kitchen question
Andy,
Today I visited the church to inspect the room the new kitchen equipment will be going in and found some fire
protection system issues that should be corrected. ls it possible to add them to the permit conditions or is it too late to
do that?
Ron Biggers
Deputy Fire Marshal
Glenwood Springs Fire Department
Fire Sprinklers Save Lives !!!
97A-384-67433
Disclaimer: Thís email message and all attachments are for the sole use of the intended recipient(s) and may contain
confidential and privileged information. Any unauthorized review, use, disclosure, or distribution is prohibited. lf you are
not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message.
Content cannot be guaranteed to be secure or error-free as information could be intercepted, corrupted, lost,
destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or
omissíons in the contents of this message, which arise as a result of e-mailtransmission. lf verification is required, please
request a hard-copy version.
From: Andy Schwa ller Imailto:aschwa ller@garfield-county.com]
Sent: Wednesday, March 09,207711:37 AM
To: Colorado Carpentry, LLC
Cc: Ron Biggers; David Bartholomew
Subject: FW: Quick kitchen question
3
GARFIELD COUNTY BT]ILDING PERMIT APPLICATION
108 8û Street, Suite 401, Glenwood Springs, Co 81601
Phone: 970-945 -8212 I Fax: 970-384-3470 / Inspection Line: 888-868-5306
www. garfield-countv. com
Parcel No: (this information is available at the assessors office 970 -945-9134)t-Oo'0>
2 Job Address: (ifan address hæ not been assigned, please Name & City) or and legal descriptionCrStreetorHwyr
3 LotNo:No:
4 Mailing Address:
5 Contrâctor:Address:
Address #6 Ph:AItPh:
7 ofSq Sq. Ft. or Acres o Height:No. of Floors:
8 Use of Building:
9 Describe Work:
10 Class of Work:
n New ¡ Addition
Septic:1l Garage:
¡ Attached ¡ Detached o ISDS
7Z
l2 Owners valuation of Work: $2 e,c
letter of authority, sigued by the Omer, must be provided with this Application.
Lesal Access, A Building Pemit cmot be issued without proof of legal md adequte access to the prcperty for purposes of impectiom by the Building Department.
Comty Highway/ Road Access or a State Wastewater Discbage Pmit.
Void Permil A Building Pemit becomes null md void if the work authorized is not comencsd within 180 clays of the date of isswce ad if work is supended or abmdoned for a period of 180
days after comencement.
CERTIFICATION
md specificatiom md other data submitted by me or on my behalf (submittals), based upon my certification as to accmcy.
the submitt¿ls reviewed by the Buil¡ting Deparbnent.
comtruction or ue of the structure(s) md facility(ies), described above, re not in complimce with Couty Regulation(s) or my other applicable law.
of Couty Regulation(s) or my other applicable law.
limitation my uchiteot designer, engineer md/ or builder.
I HEREBY ACKNOWLEDGE TFIAT I HAVE READ AND UNDERSTAND TTIE NOTICE & CERTIF'ICATION ABOVE:
c+( vrrer (Frt¿/Lt À/Nl\ïtU
NOTICE
u
eu-2'¡ûr/üet¿s-l.b STAFF USE ONLY
Special Conditions:
Adjusted Valuation:
ll,Zog.e
Plan Check Fee:
i7 6 ,Ot
Permit Fee:
zo1. z I Manu home Fee:Misc Fees:
ISDS Fee:Total Fees:
=?í" 26
Fees Paid:
.àb
Balance Due:
ø
BP No & Issue Date:
t"{0
ISDS No & Issued Date:
Setbacks:
:-zs I R- zs.' .g to '
OCC Grouo:/3 ConstType:
$E
ZoningzclL
BLDGDEPT:
APPROVAL
7 ¿
PLNG
The followins items are required by Garfïeld County for a final Inspection:
1) A final Electrical Inspection from the Colorado State Electrical Inspector.
2) Permanent address assigned by Garfield County Building Department and posted at the
structure and where readily visible from access road.
3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows
installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent
kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all
necessary plumbing.
4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running
water, non-absorbent floors, walls finished, and privacy door.
5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks
over 30" high must be constructed to all IBC and IRC requirements including guardrails.
6) Outside grading completed so that water slopes away from the building;
7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of
extenuating circumstances., i.e. weather. Under such circumstances A Certificate of
Occupancy may be issued conditionally.
8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTrL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED.
OWNER CA¡INOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED.
OCCUPANCY OR USE OF D\ryELLING WITHOUT A C.O. WILL BE CONSIDERED A¡[
ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES
UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, use and the issuance ofa
C.O. for the building identified in the Building Permit.
fu^1"-)*F*,\) &-taøeq
o SIGNATURE
Bapplicationdecember200T
TE
Description of Work: remodelexisting kitchen space
Bin #:
Location Address: 2195 CR 154
GLENWOOD SPRINGS, CO
Building Plan Review
Case Manager: David Bartholomew
Plan Case Number: BLDG-9-10-6585
Parcel: 218527100026
Application Date: 09/10/2010
Ownen Mountain View Church of Glenwood
Applicanfi Mountain View Church of Glenwood
Appllcant Phone: (970)94S8328 Email:
ContactsGeneral Inforrnation
,/
'/ Red Line Plans/stamps/sticker
'/ Attach conditions
Z^pptication sisned
Buildins
Foundation
Driveway Permit
Surveyed Site Plarl
Permit and Setbacks
raphy 30%
Residential Plan Review List
Minimum Application Questionnare
ubdivision Plat Notes
Fire Department Review
Determination/Fees
Reviewer To Sign Application
No.
PlannindZoninq
Line Setbacks
Stream Setbacks
Plain
height
Sign-off
lmpact Fees
Approval
opography 40%
lssues
Plat
U¿/a¡þør ,//, Zoo .-
/er*, / Fea z¿?' zf
/tuta.t /te /?é. r /
Plì / V/5.2L
@ sul*,/"/)
'u/n r0# snowload Letter- Manu. Homes /fu* '/¿'o/
Report -t2/l€ z
- 3/l z¿
GARFIELD COUI{TY BUILDING AND PLANNII\G
970-94s-8212
MINIMITM APPLICATION REQUIREMENTS
FOR
CONSTRUCTION OF
COMMERCIAL OR MULTI.FAMILY RESIDENTIAL BUILDII{GS
Including
NEV/ CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BTIILDINGS
In order to understand the scope of the work intended under a permit application and expedite the issuance of a
permit it is important that complete information be provided. When reviewing a plan and it's discovered that
required information has not been provided by the applicant, this will result in the delay of the permit issuance
and in proceeding with building construction. The owner or contractor shall be required to provide this
information before the plan review can proceed. Other plans that are in line for review may be given attention
before the new information may be reviewed after it has been provided to the Building Department.
Plèase review this document to determine if you have enough information to design your project and
provide adequate information to facilitate a plan review. Also, please consider using a design
professional for assistance in your design and a construction professional for construction of your
project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado
Registered Design Professional.
To provide for a more understandable plan and in order to determine compliance with the building, plumbing
and mechanical codes, applicants are requested to review the following checklist prior to and during design.
TWO (2) SETS OF CONSTRUCTTON DRA\ryrNGS & T\ryO Q) SITE PLA¡IS MUST BE
SUBMITTEDFOR ALL APPLICATIONS.
Plans to be included for a Building Permit must be on draft paper at least 18rrx 24rrrr and drawn to
scale.
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks,
balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade
line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar,
anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap,
(which is required), siding or any approved building material. Engineered foundations may be required.
I
Check with the Building Department.
A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to
withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B
or C, and a 36 inch frost depth.
All sheets need to be identified by number and indexed. All of the above requirements must be met or your
plans will be returned.
All plans submitted must be in compliance with the 2009IBC, IPC, IMC, IFGC, and IFC, 2009 IECC
Applicants are required to indicate appropriately and to submit completed checklist at time of
application for a permit:
1. Is a site plan included that identiflres the location of the proposed structure, additions or other buildings,
setback easements, and utility easements showing distances to the property lines from each corner of
the proposed structure prepared by a licensed surveyor and has the surveyors signature and
professional stamp on the drawing? Slopes of 30Yo or more on properties must be show on site plan.
(NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a
property line and not within a previously surveyed building envelope on a subdivision final plat shall
be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the
drawing. Any structure to be built within a building envelope of a lot shown on a recorded
subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the
proposed 5Íructure located within the envelope.
Yes (
2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System)
and distances to the property lines, wells (on subject property and adjacent properties), streams or
water courses? This information must be certified by a licensed surveyor with their signature and
professional stamp on the design.
Yes Not necessary for this project
3. Does the site plan indicate the location and direction of the State, County or private road accessing the
property?rr
Yes /
4. Have you provided any RESOLUTIONS and/ or LAND USE
if Yes please provide a COPY. No
PEYTT (S) associated with this property?
Yes
5. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado
Registered Engineer? //Yes_ Not necessary for this project tl
6. Are the plans submitted for application review construction drawings and not drawings that are stamped or
marked identifying them as "Not for construction, for permit issuance only", "Approval drawings
only", "For permit issuance only" or similar langyøge?
Yes_ Not necessary for this project u/
2
7 . Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in
accordance with the building code or per stargped engineered design?
Yes- Not necessary for this project i,z
8. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this
building? /Yes Not necessary for this project y'
9. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the
clearances required between wood and e¡lrth?
Yes Not necessary for project l/
10. Do the plans indicate the size and location of the ventilation openings for the attic, roofjoist spaces and
soffits? /Yes Not necessary for this project V
11. Do the plans include design loads as required under the IBC or IRC for roof snowloads, (a minimum of 40
pounds per square foot in Garfield County)? ¡Yes Not necessary for this project u/
12.Do the plans include design loads as required for þor loads under the IBC or IRC?
Yes- Not necessary for this project V/
13. Does the plan include a building section drawinrylndicating foundation, wall, floor, and roof construction?
Yes Not necessary for this project v/
14. Is the wind speed and exposure design included 'ydhe plan?
Yes Not necessary for this project V/
15. Does the building section drawing include size and¡pacing
rafters orjoists ortrusses? ,/Yes_ Not necessary for this project_( _
of floorjoists, wall studs, ceiling joists, roof
the method of positive connection of all columns16. Does the building section drawing or other detail;l¡clude
and beams? /Yes Not necessary for this project y'
5
17. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed
grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof?
(Check applicable zone district for buildineþâeht maximum)
Yes_ Not necessary for this project y'
18. Does the plan include any stove or zero clearance fireplace planned for installation including make and
model and Colorado Phase II certifications orlhase II EPA certification?
Yes Not necessary for this projeú y'
19. Does the plan include a masonry fireplace includjng a fireplaoe section indicating design to comply with
the IBC or IRC? /
Yes Not necessary for this project {
21. Does the plan include a window schedule or otþr verification that windows provide natural light and
ventilation for all habitable rooms? /Yes- Not necessary for this project v
22. Do the plans indicate the location of glazing subject to human impact such as glass doors , glazing
immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking
surface; sliding glass doors; fixed glass panelg; shower doors and tub enclosures and specify safety
glazingforthese areas? /Yes Not necessary for this project I
23.Do the plans include a complete design for all mechanical sygldrns planned for installation in this building?
Yes- No- Not necessary for this project-1r_
24.Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in
the IBC Chapter 3) /Yes_ Not necessary for this ptoject v/
20. Does the plan include a window schedule or other that egress/rescue windows from sleeping
rooms and/or basements comply with the of the IBC or IRC?
Yes Not necessary for this proj ect
25. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in
this building?
Yes Not necessary for this proj ect
26.Is the locatioq of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the
plan? /
Yes .r,/ Not necessary for this project-
4
27.Do the plans indicate the location and dimensionof restroom facilities and if more than four employees and
both sexes are employed, facilities for botþfxes?
Yes- Not necessary for this project y'
28. Do the plans indicate that restrooms and access tÁ"building are handicapped accessible?
Yes- Not necessary for this project /
29.Have two (2) c_çmplete sets of construction drawings been submitted with the application?
Yes -/
30. Have you desþed or had this plan designed while considering building and other construction code
requireþénts?
Yes {
31. Does the plan indicate what you intend to construct and what will receive a final inspection by
the County Building Department?
Yes
32.Do your plans¡omply with all zoningrules and regulations in the County related to your zone district? For
corner lold see supplemental section 3-301 in the Garflreld County ZoningResolution for setbacks.
Yes /
33. Do you un{e¡stand
impleri/ntation
Yes {
that approval for design and/or construction changes are required prior to the
ofthese changes?
34. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of
application and that you will be required to pay the "Permit" fee as well as any "Septic System" or
"Road fmpact" fees required, at the time you pick up your building permit?
Yes r#
35. Are you a\ilare tþat you are required to call for all inspections required under the IBC including approval on
a final ifction prior to receiving a Certificate of Occupancy and occupancy of the building?
36. Are you aware¡Áat the Permit Application must be signed by the Owner or a written authority be given for
an Agenffid that the party responsible for the project must comply with the Uniform Codes?
Yes /
5
37. Are you aware that you must call in for an inspection by 3:30 the business day before the requested
inspectionjrt order to receive it the following business day? Inspections will be made between
7z3Q a.mft,nd 3:30 p.m. Monday through Friday. fnspections are to be called in to 888-868-5306.
Yes {
38. Are yolu awarfhat requesting inspections on work that is not ready or not accessible will result in a
$5 0.00 rfinspection fee?
Yes V
39. Are you aware that prior to submittal of a building permit application you are required to show proof of a
legal and adequate access to the site? This may include (but is not limited to) proof of your right to use
a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. of Highway
Permit including a Notice to Proceed; a permit from the federal government or any combination. You
can contq¡l the Road & Bridge Department at 625-860L See Phone book for other agencies
Yes ,/
40. Do you undgptand that you will be required to hire a State of Colorado Licensed Electrician and Plumber
to perfoffn installations and hookups? The license number will be required at time of inspection.
Yes V
\-+
L
1. Are you aware, that on the front of the building permit application you will need to fill in the Parcell
Schedule Number for the lot you are applying for this permit on prior to submittal of the building
permit aþplication? Your attention in this is appreciated.
Yes J
42. Do you know that the local fire district may require you to submit plans for their review of fire safety
issues? /
Yes / (Please check with the building department about this requirement)
43. Do you understand that if you are planning on doing any excavating or grading to the property prior to
issuance of a building permit that you will be requirJd to obtain a grading permit?
Yes Not necessary for this project ll
44.Did an Architect seal the plans for your commercial project? State Law requires any commercial project
with occupancy of more than 10 persons as per Section 1004 of the IBC to prepare the plans and
specifications for the project.
Yes _ Not Necessary for this project
45. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. No building permit application will be accepted without such
a letter.
Yes
6
I hereby acknowledge that I have read, understand, and answered these questions to the best of my
ability.
S
Phone îZgPt@ledays); î7ø 7 I5 ^ "ø. (evenings)
,¡ylu r¿r*t u { fful creþirc,a( kn¿H Er.J
o
Project Name
Project Address:
Note:
On any of these questions you may be required to provide this information. If required information is not
supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance of the
permit.
*If you have answered "Not necessary for this project" on any of the questions and it is determined by the
Building Official that the information is necessary to review the application and plans to determine minimum
compliance with the adopted codes, please expect the following:
A. The application may be placed behind more recent applications for building permits in the review process
and not reviewed until required information has been provided and the application rotates again to first position
for review.
B. Delay in issuance of the permit.
C. Delay in proceeding with construction.
bpminrepcommJun20l0
1f
7
GARFIELD COUNTY
BUILDII{G RE QUIREMEI{TS
Codes: 2009 IRC, IBC, IFGC, IMC' IPC, 2009IECC.
Setbacks: Check subdivisions and zone district for setback requirements.
Snowload (measured at the roofl Not ground): 40PSF up to 7000ft. elevation.
50PSF 700lftto 8000ft.
75PSF 800iftto 9000ft.
100PSF 9001 to 10000ft.
!!! ALL SNOWLOADS ARE MEASURED HORTZONTALLY AT THE ROOF NOT THE GROT]ND!!!
Seismic design category: B
Weathering probability for concrete: Severe.
Termite infestation probability: None to slight.
\ilind speed: 90mph.
Decay probability: None to slight
\ilind Exposure: B or C (see section R301.2.1.4)
Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above.
Winter Design Temperature: Minus 2 to 7000ft..; minus 16over 7000ft. elevation.
Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building official
Ice shield under-layment required.
Mean Annual temp: Variable
SEE 2OO9 IECC FOR INSULATION AND ENERGY REQUIREMENTS.
I