HomeMy WebLinkAboutSeptic Permit RequiredFrom: Lindsay Krol
To: Andy Schwaller; brian golden
Cc: Ted White
Subject: Re: [External] Re: 178 Blue Heron Lane — Permit #BLRE-12-20-6636
Date: Tuesday, February 16, 2021 2:20:18 PM
Brian,
Please forward the application to me instead of Ted and then I can contact Thad for payment
of the $75.00 permit fee. Once I have received payment then I can enter the application into
the system forward it along to Ted in Public Health for review.
Thank you,
Lindsay Krol
Garfield County - Community Development
Permit Tech & Safety Committee Rep.
108 8th St., Ste. 401
Glenwood Springs, CO 81601
970-945-8212
From: Andy Schwaller <aschwaller@garfield-county.com>
Sent: Tuesday, February 16, 2021 2:03 PM
To: brian golden <brian@2757design.co>
Cc: Ted White <twhite@garfield-county.com>; Lindsay Krol <Ikrol@garfield-county.com>
Subject: RE: [External] Re: 178 Blue Heron Lane — Permit #BLRE-12-20-6636
Brian,
A OWTS permit application will need to be applied for to alter the existing system. I did forward
OWTS information to Ted for his approval. Please complete the application and forward to Ted.
We will send the building permit up front to be issued.
Thanks,
Andy Schwaller
Building Official
Garfield County
From: brian golden <brian@2757design.co>
Sent: Tuesday, February 16, 2021 12:53 PM
To: Dave Argo <dargo@garfield-county.com>
Cc: Thad Eshelman <thad@tebuilders.net>
Subject: [External] Re: 178 Blue Heron Lane — Permit #BLRE-12-20-6636
Hello Dave
Following up with our responses to address your issues noted below.
A. See revised plan set. ADU size has been reduced to the 1,000 sf max with plan adjustments
to the main and upper levels as clouded. Square Foot calcs have been adjusted as well.
B. See Septic System Design attached. Please let us or Thad Eshelman- property owner cc'd- if
an additional permit application needs to be filed.
C1582 OWTS Design Packet 1 13 21.pdf
C1582 Component Specifications 1 13 21.pdf
C. Building height has been reviewed and acceptable. Please confirm with Sheyl Bower and
Glenn Hartmann.
D. See revised plan set. Deck area has been added and clouded.
I'm anticipating you'll need hard copies of these documents dropped off as well, please let us know if
so.
Thanks
bg.
brian golden
principal
0.970.989.2757
m.970.309.0897
Begin forwarded message:
From: Dave Argo <dargo@garfield-county.com>
Date: January 20, 2021 at 7:03:50 AM MST
To: erica@2757design.co
Subject: 178 Blue Heron Lane — Permit #BLRE-12-20-6636
Erica:
We have reviewed plans for a Barn/Garage + Accessory Dwelling Unit (A.D.U.)
for the above referenced property, but cannot proceed with approvals and
issuance of a building permit until the following items have first been
addressed:
A. A.D.U. Size Exceeds Maximum Allowable Area — Total square footage
of the A.D.U. exceeds the maximum allowable square footage of 1,000
S.F. as per Garfield County's Land Use Code. Please note that main level
entry stair, closet, mechanical and stairway serving the upstairs dwelling
all count towards the maximum allowable area. Our calculations (based
on gross floor area as per the Building Code) indicate overall square
footage at A.D.U. = 1,124 S.F. There are 2 alternative approaches to
resolving this matter: (1) Amend plans to reduce overall gross square
footage below the 1,000 S.F. threshold or (2) submit a Land Use Change
Permit allowing for a "Secondary Dwelling Unit" of up to 1,500 S.F. in
size for this property. If your client wishes to pursue the Land Use
Change Permit option, please contact Glenn Hartmann, our Principal
Planner to discuss the timing and other requirements for this option.
B. Septic System — There is no septic system permit included with this
building permit application, and the site plan illustrates an existing
septic system leach field — but it is greater than 200 feet in distance
from the proposed Barn + A.D.U. Please contact Garfield County's Public
Health Dept. to discuss your options for providing a septic system for
this project and, if necessary, please provide us with a Septic System
Alteration Permit or a New Septic System Permit for this project.
C. Building Height — As shown on exterior elevations and building sections,
the average height of the upper roof of the Barn is approximately 5 -feet
higher than the 25 -foot maximum building height allowed in the "Rural"
zone district. (*Note that we are approximating building height because
there is not any existing grades information provided on the site plan,
but we have assumed that existing grades at the project site are
approximately the same elevation as the finished floor elevation.) Please
make any necessary adjustments to project design in order to comply
with 25 -foot building height requirements and provide us with
appropriate back-up information verifying building height.
D. Upper Level Deck — There is deck framing shown on the upper level
floor framing plan (see Structural sheet S1.2) but this deck does not
appear on the Architectural drawings. Please clarify and make any
necessary adjustments to coordinate drawings with regard to this issue.
Please address and/or clarify these outstanding issues so that we can finalize
our plan review for this project. In the meantime, we will place drawings in our
"pending projects" file while awaiting your reply.
Thank you for your attention to this matter.
Dave Argo
Plans Examiner
<imageooi.png>
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargoPgarfield-county.com
Web: garfield-county.com