Loading...
HomeMy WebLinkAboutPlansItem # llut-l53G2GP {53O Gallon Two Gompartment lnfiltrato¡Ð Poly Tank 61 TANKTOP HALF CONTINUOUS ELASTOMETRIC GASKET 175.6'TANK INfERIOR SEAM CLIP (86)TOP VIEW ruGN}CNT DOTTIEL(a0)TANK BOTTOM HALF 24" ACCESSPORT wfrH LocKrNG LrD (3) Tancf¿d/uære @ up+eresr SEAM sEcïoN DËTA|L OUTLETTEE 2'3 TOTALVOL 1I3 TOTAL VOL SIDE VIEW SEAM CLIP r Compliont with CSA ond IAPMO Stondords¡ PVC risers ovoiloble¡ Secondory sofety screen ovoiloble wíth PVC riserr Moximum buriol depth is 48"¡ Minumum buriol depth is 6"¡ Tonk is not roted for vehiculor troffic looding¡ Exterior of monhole cover íncludes the following worning: "DANGER DO NOT ENTER: PO|SON GASES" LIFTINGSTRAP crYHcAr) END V¡EW ffir,rrnil*n' l[nÆuÍt$ãßrê o o € o Ë o o <!: o E o o <:OEàilIt FIBERGIÁSS SUPPORT f" 1 SLOT Digging Specs lnvert Dimensions Net Weight 16' Long x 7' Wide 43" below inlet lnlet 47" Outlet 44" Length 175.6" width 61.7" Height 54.5"501 lbs.1006 gol 503 9ol 1509 9ol Wtrr& Wa¡teulúr ¡ SYEteme ¡ Producûs Inc. o SeMce Fro) 395626¡t ãrFco' ru'$7 P.O.Bo(æ5 Fax (719) 39S3727 RHEVlda' æ81z.1 Webclb: wunv.valleypreætæm Brnll : fronüæl@Malle¡¡pmtæm, PRTCASI, Residential B¡otube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime wârranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfi elds. 4-in. (100-mm) Biorube Efihrent Fiher 4-in. (I 00-mm) Biontbe Jr. (4-in. Biotube cartridge auail- able separateþ as Inserr Fiher) B-in, (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Fiher !3G :. ËF. Orencoi superior ffiuent flters resist clogging better t/tan all other brands. Ottr strtn' dard, fttll-sized 4-in. (100-mm) Biontbe Effluent Fiher prouides maximttm long-term protection in a complete pncÞttge, with housing. C)ur 4-in. (100-mm) Biotttbe Jr., at half rhe size of ou.r standard model, has more filtering capttcity than the full-sized flters sold by other marutfacturers. For títnþr with existing outlet tees, the Biotube Insert Fiher is ideø|. Andfor low-profle tanþs, there's the Base Inlet Filter. * Cove¡ed by patenr nunrbers 5,492,635 and 4,439,323 To 0rder Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu- tot call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS.Ff-1 Rev. 3.4 @ 11l10 0renco Systems@, lnc. , i I : : ::j , t';. ir:''. : .'i:, ::: ,-: i* :. I :i:.l ' i:.-;;, i,.,tiir l:! ,:; lËiii fg fu*H' Standard Features & Benefits . Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfa ctio n . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal . Easyto clean by simply hosing off whenever the tank needs pumping . Removes about two-thirds of sus- pended solids, on average, extending drainfield life . Corrosion-proof construction, to ensure long life . Lifetime warranty 0ptional Features & Benefits Biotube Filtering Process . Alarm available,to signal the need for c lea ning . Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and in c reasing retention time . Custom and commercial sizes availa ble Effluent from the relatively clear zone ofthe septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire sudace for filtering. Pafticles larger than the Biotube's mesh are prevented from leaving the tank. - .'.! *.' *.*t € Orenco Systems llti:t-i4:i:t*lc¡ {.1;,::4çlr3' úe 11:Í:1, ¡Lr¡ ll?;l¿f l-l ¡rr ll?¿r¡sr¡,¿r¡¡'' www.otênÈı.salnl Nomenclatures 4-in, Biotube Filter (standard) FT 04 T 4-in. Biotube Effluent Filter EKendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube@ filter cartr¡dge Solid base Filter housing 4-in. Biotube Jr. Tank wall 0ptions: Blank = no optionslVl = flow modulati0n plate installedA = float brackel atlached Cartridge height: 28" and 36" are standard H0using height: 36" and 44" are standard Filter diameter (inches) W = fitsType 3034 outlet pipe S = fits Schedule 40 outlet pipe 8-in. Biotube Filter (base intetmodet) FT 08 22 -148 0ptions:A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate. Ease inlet model Cartridge height: 14" standard Housing height: 22" standard Filter diameter (inches) 08=8" Blank = 1/S" filtrationP = 1/16" filtration Biotube effluent filter series Biotube effluent filter ser¡es Blank P 1/8" filtration 1 /1 6" filtrat¡on - Riser wall . Also available with coupling and sleeve as a "kit": FI-OVERFL0WKIT 4-in. Biotubê Jl. (includes caftridse and housins) FTJ nlo¿ te I 0ptions: Blank = no optionslV = flow modulation plate installedA = float bracket attached Cartridge height (inches) Filter diameter (inches) W = f¡lsType3034oulletteeS = fits Schedule 40 outlet tee 4-in. Biotube Filter lnsert (cartridge onty) FT ¡ !04 ls -n Junior series Biotube effluent filter series Blank = 1/8" filtrat¡onP = 1/1 6" filtration Blank = 1/B" filtrationP = 1/16" filtration -T-ror rrr,orrrd options (e.g., NC indicates North Carolina regi0ns) W = fitsType3034outletteeS = fits Schedule 40 outlet tee Cartridge height (inches) Filter d¡ameter (inches) lnsert Biotube effluent filter ser¡es Distributed By: Double Walled PVG Riser & L¡d Options Poly Lid (Statlc load tested b 5000lbs)¡ Skid resistance surfacer Avallable ln greeno Highest level of UV Probcton induded¡ lncludes a bam gasket fur airtight and watertight applications¡ lncludes squarc drive screu¡s b dieoounage unauthorlzed enfy¡ lnsulation panels achleve R-lOlnsulation raüng 2'of lnsulation Standard Orenco @ DuraFlberm Access Lids (FLD) Not rccommended fur vehicr¡larffic 24' and 30'Dlametens. Solld, rcsin-lnfused fiberglass constuc{on. 20,000{b brcaking sü€ngrh. Standard grcen or hrnrn ooloe. Available with orwithout urelhane lid gasket. Available with carbon filüation. 4 stainleee steolf,athead socket cap scr€ws & hex key wrencfr lnsulated llds avallable-2" or4'a Double Walled PVG Riser . Avallable ln 24' and 30" Dlamgbr. Gut to lengür. Sold ln +l-2'lncremenb. Must be cut bstireon ribg t¿¡!Zi!Z¡!Zi!Z¡! Wúr&WaSffir o S)Ftems r Prcduds fnc. I SeMcefM, Fr9) 395€7Ot ãËooRd3l7 P.O.Bo(æ5 Fax (719) g9+g7n BsEvlsta' æ81211 Weblb: www.valleyprcrutærr Emall : fronHæl@[ldeyprcætæm POLYLOK DTSTRIBUTION BOX, RlsERS, AND LID UD.BOX6&UD€OX8 D.BOX SEAL (EìrwD.æ(ofrEgûffir asE r¡) 16"SIDE CUT OUT TO ACCEPT POLYLOK SEAL NO.3o01 TEAROUT FOR 4" SDR-35 0R SCHD.40 NOr ro scÁrE UD.BOX O'RISER ROTO#LOW4' I 6n i UD€OX 12'RISER NOT TO SCA¿.E POLYLOGK EQUAIJZER 'v-NoTcH'wElR 1 t8 rsw8E¡r.Eì/E¡lO RIBS PR(ryDEFREIK¡i¡ FrfFORAIIf PfEIO -------+ + 20' COVER FOR RISER & D€OX lrol¡osG/uE GASKETED SEAL ON LID & RISER VALIEY Wtrr& Wa¡leuater o SlatemE ¡ Prcducils 0r9)89ı€704 2tHCoRd'317 P.O. Bo(æ5 Farc (219) ggæTn RsE\eh' æ81211 Webclb: wmv.valle¡¡pmætærr Emall : ftonüesk@vallenreætæmf PRTCAS[¡rnc. oservloe Ouick4 Plus All-in-One Periscope Ouick4 Plus Standard Chamber Ouick4 Plus All-in-One 12 Endcap Center Structural Columns The Ouick4 Plus Standard Chamber offers max¡mum strength through its two center structural columns, This chamber can be installed in a 36-inch-wide trench. Like the'original line of Ouíck4 chambers, it offers advanced contouring capabil¡ty with its Contour Swivel Connectionr" which permits 10-degree turns, right and left. lt is also available in four-foot lengths to provide optimal installation flexibility. The Ouick4 Plus All-in-One 12 Endcap, and the Ouick4 Periscope are available with this charnber, providing increased flexibility in system configurations. Ouick4 Plus Standard Chamber o Two center structural columns offer increased stability and superior strength o Advanced contouring connections o Latching mechanism allows for quick inslallation o Four-foot chamber lengths are easy to handle and install . Supports wheel loads of 16,000 lbs/axle with 12" of cover Ouick4 Plus All-in-One 12 Endcap . May be used at the end of chamber row for an inlet/ outlet or can be installed mid-trench o Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows . Center-feed connection allows for easy installation of serial distribution systems . Pipe connection options include sides, ends or top Quick4 Plus All-in-One Periscope . Allows for raised invert installations . 180o directional inletting o Twelve inch raised inveri great for serial applications =0ui^çß,#PÍ"US 'llgr , | , rl I i ;ù 'J,ir l¡t /'==? 1¡1n, ru THE OUICK4@ PLUS SÏANÐARD CHAMBER Quick4 Plus Standard Chamber Side and End Views 48' (EFFECTIVE LENGTH) Quick4 Plus All-in-One 12 Hncap Front, Side and Hnd Views 34 12" 5.3" INVERT r 't1.2', 13" 8'INVERT i Quick4 Plus All-in-One Periscope OUICK4 PLUS ALL.INONE (360'SW¡VEL ) 8'INVERT _L 33" QUICK4 PLUS ALL]NONE 12 ENOCAP .hgmt J,,,[ !,]12.7'INVERT INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WAFRANTY (a) fhe structural integrity of each chamber, end plate, wedge and olher accessory manufactured by lnfiltrator ( "Units"), when installed and operated in a leachf¡eld of an onsite septic system in accordance with lnfiltraloas instiuctions, is waranted to the original purchaser ("Holdea') against defective materials and workmanship for one year from lhe date that the sept¡c permit is issued for the septic syslem containing the Units; provided, however, lhat if a septic permit is not required by applicable law, the watranty period will begin upon the date that installation of the septic system commences. To exercise ¡ts waranty r¡ghls, Holder must notify lnf¡ltrator ¡n writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. lnfiltralor w¡ll supply replacement Units lof Units determined by lnf¡ftrator to be covered by this Limited Waranty. lnf¡ltrator's liability specifically exc¡udes the cost of removal and/or ¡nslallation of the Units. (b)IHE Lli\,4lTED WARRANTY AND FìEl\,4EDlES ¡N SUBPABAGRAPH (a) ARE EXCLUSIVE. THERE AFE NO OTHER WARRANTIES WITH RESPECT TO THE UN S, INCLUDING NO IN,4PLIED WARRAN'TIES OF IVERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) Th¡s Limited Warranty shall be void ¡f any part of lhe chamber system ¡s manufactured by anyone other than lnf¡ltrator. The Limited Watranty does not extend to incidental, consequential, special or indìrect damages. lnfiltrator shall not be liable for penaltìes or l¡qu¡dated damages, including loss of production and prof¡ts, labor and mater¡als, overhead costs, or other losses or expenses incured by the Holder or any th¡rd party. Spec¡fically excluded from Limited Watranty coverage are damage to the Un¡ts due to ordinary wear and tear, alteration, acc¡dent, misuse, abuse or neglect of the Units; the Units be¡ng subjected to vehicle traffic or other cond¡tions which are not permitted by the ¡nstallalion instructions; failure to ma¡ntain the m¡n¡mum ground covers set forth in the installation instructions; the placement of improper materials ¡nto the system containinq the Units; faìlure of the Unils or the septìc system due to improper siting or improper sizing, excessive water usage, improper grease dìsposal, or improper operalion; or any other event not caused by lnfiltrator. This L¡mited Warranly shall be void if the Holder fa¡ls to comply w¡th all of the terms set forth in this L¡mited Waranty. Further, ¡n no event shall lnfiltrator be responsible lor any ìoss or damage to lhe Holder, the Units, or any third party resulting from ¡nstållatìon or shipment, or from any product liab¡lity claims of Holder or any third party. For this Limited Watrânty to apply, the Units must be ¡nstalled ¡n accordance with all site cond¡tions required by state and local codes; all other applicable laws; and lnfiltratols instalfatÌon inskuctions. (d) No represental¡ve of lnfiltrator has the aulhorily lo change or extend this Lim¡ted Warranty. No warranty applies to any party other than the original Holder. The above represenls lhe Standard Limited Warranty offered by lnfiltrator. A l¡mited number of stales and counties have different waranly requirements. Any purchaser of Units should contact lnfiltrator's Corporate Headquarters ¡n Old Saybrook, Connecticut, prior to such purchase, lo obtain a copy of lhe applicable waranty, and should carefully read thal waranty prior lo the purchase of Units. IN FILTRATOR' systems inc. 6 Business Park Road . P.O. Box 768 Old Saybrook, CT 06475 860,577.7000 . FAX 860,577.7001 800.221.4436 www. i nf iltratorsystems.com l \( Ouick4 Plus Standard Chamber Specifications Size(WxLxH)34" x 53" x 12" (86 cm x 135 cm x 3'1 cm)lnvert Height,.,.,.........,.. 0.6",.5.3", 8.0'r, 12.7n (1.5 cm, 8.4 cm, 18.5 cm, 22.6 cm)Effective Length 48" (i22 cm) THE OUICK4@ PLUS STANDARD CHAIVBER u.s. Patentsi 4,759,661;5,017,041;5,156,488; 5,336,017; 5,401,1 16; 5,401,459; 5,51 1,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. lnfiltrator, Equalizer, Quick4 and Quick4 Plus are registered trademarks of lnfiltralor Systems Inc. lnfillrator is a registered is a registered trademark in Mêxico. Contour Sw¡vel Connection is a trademark of lnliltralor Systems lnc. @ 2009 lnfiltrator trademark in France. lnfiltrator Systems lnc. Systems lnc. Printed in U S.A.PLUS05 1010rSt-2