March 29, 2021 Project No. C1301
Tara Dakides
tdakides@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
1212 Panorama Drive Carbondale, CO 81623
Garfield County, Colorado
Permit Number SEPT-09-17-4928
Tara,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on December 15, 2017 and June 27, 2019 for the subject property. We also conducted several site visits
since the installation. AML Construction installed the system.
The system was sized to accommodate 3 bedrooms in the caretaker dwelling unit (CDU) and 4
bedrooms in a future main house. A design flow of 975 gallons/day was used to design the system.
A separate Septic Permit will need to be obtained from Garfield County prior to installing a septic tank for
the main house.
The minimum 50-feet setback from the ditch to the soil treatment area (STA) was verified.
The system installation included a 1500-gallon, two-compartment concrete septic tank with an Orenco®
ProPak and PF3005 pump in the second compartment. There is a filter in the second compartment
of this septic tank which must be cleaned annually, or as needed. The floats were set to dose
approximately 80 gallons each pump cycle. The control panel is located within line of sight of the septic
tank. Jerry Fleck performed start-up of the pumping system.
A 1.5-inch diameter Schedule 40 pump line was installed from the pump to an Orenco® automatic
distributing valve (ADV), model 6605. This pump line has a minimum 1% grade for proper drain back into the
tank after each pump cycle. The ADV is located at a high point in the system and was placed in an insulated
riser with access from grade.
Effluent is pressure dosed through 1.5-inch diameter pipes to five trenches, each with 19 ‘Quick 4’
Standard Infiltrator® chambers, for a total of 95 chambers and 1140 square feet of infiltrative area. There
was at least 6-feet of undisturbed soil between each trench. Effluent is pressure dosed to 1.5-inch
diameter laterals, which were hung with zip ties from the underside of the chambers. Laterals have 5/32-
inch diameter orifices facing up, with the exception of the first and last holes facing down for drainage.
Orenco® Orifice Shields were placed under each downward-facing orifice. The orifices were placed 3-
feet on center. Each lateral ends in a 90-degree ell facing up with a ball valve for flushing. Valves were
placed in a valve box, accessible from grade for access. Inspection ports were placed at the beginning
and end of each trench. Ports may be cut to grade and covered with a valve box for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS Richard H. Petz,
Over excavation for septic tank inlet tee
3/30/2021
Trench excavation
Sewer line from foundation to septic tank pump line from septic tank to ADV
ADV prior to setting riser trenches
trenches
1 / 1
Bill To:Carla Ostberg
Carla.ostberg@gmail.com
33 Four Wheel Drive Rd
Carbondale, CO, 81623
Invoice No:23
Date:10/20/2019
Terms:NET 30
Due Date:11/19/2019
Description Quantity Rate Amount
Pump Start Up and Verification 1212 Panorama 1 $350.00 $350.00*
*Indicates non-taxable item
Subtotal $350.00
Total $350.00
PAID $0.00
Balance Due $350.00
Jerry L Fleck Invoice
2599 East Drive
Monte Vista, CO 81144
jerrylfleck68@gmail.com
719 221 6703
PERMIT CARD
POST THIS IN A CONSPICIOUS PLACE WHEN CONSTRUCTION IS STARTED
Project Address ____________________________________ Parcel No. ________________________
Owner Name _______________________________________ Owner Phone _____________________
Contractor(s) _______________________________________ Contractor Phone _________________
Work Description ______________________________________________________________________
AGREEMENT
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning,
location, construction and erection of the proposed structure for which this permit is granted. The applicant further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit
may then be revoked by notice from the County Building division and immediately become null and void.
Inspection Comments Pass Date
Perc Test
Final
PLEASE SEE BACK OF PERMIT FOR OTHER COMMENTS
Permit Type ____________________________________
Work Classification _____________________________
Issue Date ___________ Expiration Date ___________
PERMIT #
Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601
Phone (970) 945-8212
ADDITIONAL INSPECTIONS MAY BE REQUIRED
For Inspections Call (970) 945-1377 x1621
For Driveway Inspections Call (970) 625-8601
11/16/2018
new OWTS installation for single family
Septic - New
760-271-5961
AML Construction
Jake Zamansky & Tara Dakides
970-309-7331
SEPT-09-17-4928
239117102003
New
11/16/2017
1304 Panorama Dr.