Loading...
HomeMy WebLinkAboutObservation of Excavation 11.01.2016H-p*KUilVIAR 5020 Gounty Road 154 Glenwood Springs, CO 81601 Phone: (970) 945"7988 Fax (970| 945'8454 Email: hpkglenwood@kumarusa.com Geotechnical Ênçineering [ Ëngineering Geology Matsrials Tesling I Envlrontnental Office Locatlons: Parkor, Glenwood Springs, and Silverthome, Colorado November 1,2016 Glen McPherson 2291 County Road 3l I New Castle, Colorado 81647 gmcpherson @ masterpetroleum.com Project No. l6-7-546 Subject:Observation of Excavation, Proposed Addition to Garage, 2299 County Road 3l I (Divide Creek Road) South of Silt, Garfield County, Colorado Dear Glen: As reques of HP/Kumar observed the excavation at the $ubject site on October 2026 evaluate the soils exposed for foundation support. The findings of our s for the foundation design are presented in this report. The services were performed in accordance rvith our agreement for professional engineering services tCI you, dated October26,2016. The addition will be attached to the .south side of the existing garage and be a single story of wood frame construction with a slab-on-grade floor. The building has been designed to be supported on sprend footing.s. At the time of our site visit, the foundation exc¡rvâtion which was essentially completc had been cut in one level from about ZVzto37rfeel below the adjacent ground surface. The soils exposed in the bottom of the excåtviltion consisted of medium dense, silty sand with scûttered silty clay pockets. Results of swell-consolidation testing performed on samples taken from the site, shown on Figure l, indicnte the soils are moderately compressible under conditions of loading and wetting with a low hydro-compression potential. No free water w¡¡s encountered in the excavation and the soils were generally moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable bearing pressure gf I,500 psf can be used for support of the proposed addition. There may be some foundation seËm-errtþEcially if the beaiing soils were to become wetted, and precautions should be taken to prevent wetting. The settlemenL mây be differential with respect to the existing structure which should be considered in the design. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed natural soils, and the subgrade compacted. Exterior footings should be provided with adequate Clen McPherson November 1,2016 Page2 soil cover above their bearing elevations for frost protection. Continuous foundation walls should be well reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least l2 feet. Structural fill placed within floor slab areas can consist of the on-site soils compacted to at least 957o of standard Proctor density (SPD) at a moisture cCIntent near optimum. Backfill placed around the structure should be compacted to at least 907o SPD (9570 in slab areas) and the surface graded to prevent ponding within at least l0 feet of the building. Landscape that requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within l0 feet of the foundation. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater thnn indicated in this report bec¡use of possible variations in the subsurface conditions. [n order to reveal the nrture and extent of variations in the.subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted" If you have any questions or need further assistance, please call our office. Sincerely, I{-P\ KU David A. Young, DAY/ksw attachment Figure l, S on Test Results H-P E KUMAR Project No. 16-7-546