Loading...
HomeMy WebLinkAboutEngineer Report 10.02.2020LETTER OF CERTIFICATION PREMO STEEL BUIDLINGS 5912 S. CODY ST SUIÏE 209 LITTLETON, CO 80123 JOB NO.: '110355-RA CUSTOMER: GLEN MCPHERSON JOBSITE: 229 COUNTY RD 31'1 NEW CASTLE, CO 80,123 COUNTY: GARFIELD BUILDING END USE:OTHER To whom it may concern: pREMO STEEL BUIDLINGS, certifies that the above structures were designed in accordance with the A.l.S.C. Speci¡cation for Structural Steel Buildings - Allowable Strength Design, ANSI/AISC 360-10, the A,l.S,l. Standard, North American Specification for Design of Cold-Formed Steel Structural Members, 2012 Edition, A.W.S. D1 .1-1 0 Structural Welding Code - Sheet Steel and generally accepted engineering practices. Loads applied to design the building/s are no less than the requirements prescribed in the order document and the design satisfies the requirements of the 2015 lnternational Building Code. (Refer to Building Description and Design Loads on succeeding pages) Accessories provided by others are to sustain the design wind load. Likewise, the customer is to ensure that the above comply with the requirements of local regulatory authorities. Open web joists, if used and supplied by'PREMO STEEL BUIDLINGS shall be from a Steel Joist lnstitute (SJl) approved manufacturer. This Letter of Certification covers only the design of the steel building and its components. lt specifically excludes accessories, anchor bolts, foundation, masonry, or general contract work as well as erection certification, Sincerely, ana ron Engineer r01212020 Page 1 of 3 Continuation of JOB NO.:I 10355-RA BUILD ING DËSCRIPTION BUILDING FRAME TYPE wrDTH (ft) LENGTH (ft) EAVE HETGHT BACK SIDEWALL (ft) EAVE HEIGHT FRONT SIDEWALL (ft) ROOF SLOPE BACK SIDEWALL (ft) ROOF SLOPE FRONT SIDEWALL (ft) BAY SPACING FROM LEFT TO RIGHT (ft) AB RF LT 4AM 60 60 16 13.7 16 16 2.0.12 2.0:12 2.0:12 3 @ 20'-0" DESIGN LOADS DESIGN CODE ENCLOSURE DEAD LOAD (ps0 COLLATERAL LOAD (Psf) WIND LOAD ultimate wind (mph) Wind lmportance Factor, lw Wind Exposure lnternal Pressure Coefficient, GCPi LIVE LOAD Primary Framing (psf) Tributary Area Reduction Secondary Framing (psf) SNOW LOAD Ground Snow Load, Pg (Psfl Roof Snow Load, Pf (psÐ Sloped Roof Snow Load, Ps (Psf) Snow Exposure Factor, Ce Snow lmportance Factor, ls Thermal Factor, Ct Slope Factor, Cs SEISMIC LOAD Seismic lmportance Factor, le Seismic Occupancy Category Site Class Mapped Spectral Response Acceleration Spectral Response Coefficient Seismic Design Category, SDC Basic Force Resisting Systems Used Total Design Base Shear, V (kips) Response Modification Factors, R Seismic Response Coefficients, Cs Analysis Procedure Used RAI NFALL INTËNSITY (inches/hr) lBc 15 c Building Structure Only 0.5 57 40 40 1 1 1 I 115 1 c 0.18 -0.18 20 No 20 I il D Ss= 0.316 51- 0,081 Sds= 0.326 Sdl= 0.130 B Steel System Not Detailed For Seismic Resistance Rigid Frames & Braced Frames 3.64 Rigid Frames = l End Wall x Bracing = J Side Wall x Bracing - 3 Rigid Frames = 0. 11 End Wall x Bracing = 0.'1 1 Side Wall x Bracing = 0. 11 Equivalent Lateral Force Procedure 11= 4 12= Page 2 of 3 ContinuatÍon of JOB NO.: 110355-RA EFLECTION LIMITS Endwall Column Endwall Rafter Live Endwall Rafter Wind WallGirt Pudin Live I 0 120 60 150 120 60 124Purlin Wi nd Rigid Frame Vertical Wind Bent Rigid Frame Crane Rigid Frame Seismic Wind Bent Seismic 180 120 90 150 Wall Panel Roof Panel Live Roof Panel Wind Rigid Frame Horizontal 60 00 50 50 CRANE LOADS A system C Type Vertical lmpace Factor Rail Type Capacity (Tons) Service Class Bridge Weight (lbs) Trolley Weight (lbs) Max Wheel Load (lbs) Wheel Base Outside (ft) Wheel Base lnside (ft) Crane 1A Crane 2A Crane 18 Crane 2B Crane 1C Crane 2C Mts¿¿ANI LOADS Mezzan¡ne 1 Mezzanine 2 ezzanine 3 Dead Load (psf) Partition Dead Load (psf) Collateral Load Above (psf) Collateral Load Below (psf) Live Load (psf) Page 3 of 3