Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 04 27 2021 Expiration Date 04 27 2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: Lot 2, CCP Subdivision, New Castle, CO 81647 Parcel No.: 218105101296
Owner Name: Abel Gomez Owner Phone: (970) 366-9210
Designed By: CBO, INC. Designer Phone: (970) 309-5259
Number of Bedrooms: 6 Minimum Tank Capacity: 1,750-gallon Minimum Absorption. 1.125 ftz
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated April 23, 2021. Changes to the design and permit must be approved by
Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new six -bedroom residence. The system will consist of a new, two -
compartment 2,000-gallon septic tank set level with access to grade with an effluent filter in the
outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access to grade
distributing effluent to 1,152 ftZ of STA. The STA will consist of six trenches of chambers, each trench
with 16 'Quick 4' Standard Infiltrator chambers for a total of 96'Quick 4' chambers (1,152 ftz).
Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations
as designed.
CONDITION OF APPROVAL: TWO PROFILE PITS SHALL BE EXCAVATED AND EVALUATED BY THE
DESIGNER IN THE AREA OF THE PROPOSED STA PRIOR TO INSTALLATION OF THE OWTS AS
DESIGNED TO VERIFY SOIL CONDITIONS ASSUMED FOR THE STA. A REVISED REPORT SHALL BE
SUBMITTED TO GCPH PRIOR TO INSTALLATION OF THE OWTS COMPONENTS.
Contact the designer and Garfield, County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
//A
F+ r
04/27/2021
Issued By: Garfield County Environmental Health Date
Department