HomeMy WebLinkAboutConditions of PermitCONDITIO NS OF PERMIT
BLCO-O 4-21-67 83
CCC-B LLLP / Rudd Construction
Manufactured Steel Warehouse - Building B
62 County Road 1 13 (Cattle Creek Rd), Carbondale
1) ALL WORK SHALL COMPLY WITH THE FOLLOWING: 2015 I'B'C,, l.M'C', l.P.C',
I,F.G.C,, I.F.C., AND 2OO9 I,E.C.C. AS WELL AS MANUFACTURER'S INSTALLATION
REOUIREMENÏS,
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING
REOUIREMENTS AND INSPECTION POLICIES.
3) ALL WORK TO COMPLY WITH "COMMERCIAL LIMITED" ZONE DISTRICT
REGULATIONS PER GARFIELD COUNry'S LAND USE & DEVELOPMENT CODE
WORK SHALL ALSO COMPLY WITH FLOODPLAIN DEVELOPMENT PERMIT
REOUIREMENTS AND O.W,T.S. REOUIREMENTS,
4) BUILDING APPROVED AS OCCUPANCY GROUP F-1: "MODERATE-HAZARD
FACTORY INDUSTRIAL" AND CONSTRUCTION ryPE II-8. THE MAXIMUM
ALLOWABLE OUANTITY OF FLAMMABLE & COMBUSTIBLE MATERIALS SHALL BE
PER I.B,C. SECTIONS 413 & 414, AND THE MAXIMUM ALLOWABLE OUANTITIES OF
HAZARDOUS MATERIALS PER LB,C,, TABLE 307.1(1).
5) TH|S BU|LD|NG tS APPROVED FOR CORE & SHELL CONSTRUCTION ONLY. ANY
SUBSEOUENT TENANT IMPROVEMENTS WILL REOUIRE ADDITIONAL BUILDING
PERMITS, AND INTERIOR PARTITION WALLS SEPARATING INDIVIDUAL TENANTS
SHALL COMPLY WITH "FIRE PARTITION" REQUIREMENTS PER I.B,C., SECTION 708
ó) CONTACT LOCAL FIRE DISTRICTTO REVIEW l.F.C. REOUIREMENTS, FINAL
APPROVAL REPORT FROM FIRE DISTRICT IS REOUIRED PRIOR TO FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY,
7) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION, 1500 P.S.F
s) ALL HtcH-STRENGTH BOLTTNG & FTELD WELDING REOUIRES SPECIAL INSPECTOR
PER I,B.C., CHAPTER 17, PROVIDE APPROVAL REPORT AT FRAME INSPECÏION,
conditions continue next page
9) ALL EGRESS DOORS SHALL MEET |CC/ANSI A117.1-2009 FOR ACCESSIBILIry
LOCKS, LATCHES & LANDINGS PER I.B,C., SECTION 1008. VERIFY EXIT
DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH-IN INSPECTION.
10)BUtLDtNG SHALL COMpLy W|TH ACCESSIBILITY REOUIREMENTS PER LB.C.,
CHAPTER 11 AND ICC/ANSI A117 -2OOg,INCLUDING PARKING, SITE ACCESS,
ENTRANCES AND BATHROOMS. BATHROOM FACILITIES SHALL MEET MINIMUM
REOUIREMENTS FOR SIZE, LAYOUT, CLEARANCES, FEATURES, ETC,
1 1)BATHROOM INTER|OR F|N|SHES INCLUDING FLOORS, WALLS AND WALL BASES
SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE AND TO OTHERWISE
COMPLYWITH I.B.C, SECTION 1203 "TOILETAND BATHROOM REOUIREMENTS",
12)LIGHT & VENTILATION PER LB.C,, CHAPTER 12 AND LM.C. CHAPTER 4
13)ELECTRTCAL PERM|TTING & TNSPECTIONS BY COLORADO STATE ELECTRICAL
BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION,
AND FINAL APPROVAL IS REOUIRED PRIOR TO FINAL INSPECTION & CERTIFICATE
OF OCCUPANCY.