HomeMy WebLinkAboutPermitGarfield County
Publíc Heqlth
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 8160L
Phone: (970) 945-6614 ext. 8150
Permit Number SEPT-6815
Permit Type X nbt'v X Repair X Remodel/addition X Tank only
lssue Date 05/05/2027 Expiration Dale O5/05 /2O22
For inspections, call: 970-945-66f4 ext. 8150 and call the Design Engineer, if applicable
Project Address: Silt Mesa and Antlers Lane, Rifle, CO 81650 Parcel No.: 2t7906100736
Owner Name: Oscar Martinez Owner Phone: (970) 618-L027
Designer Phone: (970) 309-5259Designed By: CBO, lnc,
Number of Bedrooms: 5 Minimum Tank Capacity: 1,750-eallon Minimum Absorption: 1,t20 ft
OWTS PERMIT
KEEP AVAITABLE AT PROJECT SITE
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, lnc. dated March 7,2A2t. Changes to the design and permit must be approved by
Garfíeld County Public Health and the designer prior to construct¡on,
The new OWTS wíll serve a new five-bedroom residence. The system will consist of a new, two-
compartment 2,000-gallon septic tank set levelwíth access to grade with a high-head pump in the
second compartment of the new tank. Effluent will be pumped to an automatic d¡stributing valve set
at the high point of the system that will distribute effluent to 1,152 ftz of 5TA. The new STA will
consist of six gravelless chamber trenches, with 16 chambers per trench (96 chambers total). Due to
high groundwater, trenches are to be no deeper than 2 feet below grade. Distr¡bution laterals are to
be I% inch Schedule 40 PVC, with 5/32-inch orifices 3-feet on center and the laterals ending in
flushing valves at the distal end of the laterals. Laterals are to be hung from the underside of the
chambers wíth zip-ties. The qrifices are to be facing upward, except for the first and last orifice
(which shall face downward for drainage purposes). lnspection ports are to be installed at each end
of each trench. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Flealth at least 48 hours prior Ìo requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
ln consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
owTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not futly complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void'
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the owTS Act, the regulations adopted thereunder, or any terms and conditions of a permit'
Permit APProval
plans and specifications for the proposed owTS have been reviewed and are considered
satisfactory. permission is hereby given to the property owner(s)to perform the work indicated
in accordance with the Garfield county owTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
I
4
t)(¿f(. e-
Datelssued By: Garfield County Environme ntal
De artment