Loading...
HomeMy WebLinkAboutPermitGarfield County Publíc Heqlth Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 8160L Phone: (970) 945-6614 ext. 8150 Permit Number SEPT-6815 Permit Type X nbt'v X Repair X Remodel/addition X Tank only lssue Date 05/05/2027 Expiration Dale O5/05 /2O22 For inspections, call: 970-945-66f4 ext. 8150 and call the Design Engineer, if applicable Project Address: Silt Mesa and Antlers Lane, Rifle, CO 81650 Parcel No.: 2t7906100736 Owner Name: Oscar Martinez Owner Phone: (970) 618-L027 Designer Phone: (970) 309-5259Designed By: CBO, lnc, Number of Bedrooms: 5 Minimum Tank Capacity: 1,750-eallon Minimum Absorption: 1,t20 ft OWTS PERMIT KEEP AVAITABLE AT PROJECT SITE Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CBO, lnc. dated March 7,2A2t. Changes to the design and permit must be approved by Garfíeld County Public Health and the designer prior to construct¡on, The new OWTS wíll serve a new five-bedroom residence. The system will consist of a new, two- compartment 2,000-gallon septic tank set levelwíth access to grade with a high-head pump in the second compartment of the new tank. Effluent will be pumped to an automatic d¡stributing valve set at the high point of the system that will distribute effluent to 1,152 ftz of 5TA. The new STA will consist of six gravelless chamber trenches, with 16 chambers per trench (96 chambers total). Due to high groundwater, trenches are to be no deeper than 2 feet below grade. Distr¡bution laterals are to be I% inch Schedule 40 PVC, with 5/32-inch orifices 3-feet on center and the laterals ending in flushing valves at the distal end of the laterals. Laterals are to be hung from the underside of the chambers wíth zip-ties. The qrifices are to be facing upward, except for the first and last orifice (which shall face downward for drainage purposes). lnspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Flealth at least 48 hours prior Ìo requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. ln consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed owTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not futly complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void' The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the owTS Act, the regulations adopted thereunder, or any terms and conditions of a permit' Permit APProval plans and specifications for the proposed owTS have been reviewed and are considered satisfactory. permission is hereby given to the property owner(s)to perform the work indicated in accordance with the Garfield county owTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. I 4 t)(¿f(. e- Datelssued By: Garfield County Environme ntal De artment