HomeMy WebLinkAboutPermitGørfield County
Pu c eo
Garfield county Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601.
Phone: (970) 945-66L4 ext. 8150
Permít Number SEPT-6822
Permit Type X ¡Verv X Repair X Remodel/addition X Tank only
lssue Date OSII9|\AU.Expi rar¡on Date o51L912022
For inspections, call; 97A-945-66t4 ext. 8150 and call the Design Engineer, if applicable
ProjectAddress:233 ElkVallev Lane New castle, CO 81647 Parcel No.: 212307200738
Owner Name: Ke¡th Wittenberg Owner Phone: (970)948-3101
Designed By: Huddleston-Berrv Engineerins and Testing, lnc. Designer Phone: (970) 255-8005
Number of Bedrooms: 3 Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 630 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT S¡TE
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by Huddleston-Berry Engineering and Testing, lnc. submitted vía emaíl on May 19,202I
Changes to the design and permit must be approved by Garfield County Public Health and the
designer prior to construction.
The new OWTS will serve a three-bedroom residence. The system wíll consist of a new, two-
compartment 1,000-gallon septic tank set level wíth access to grade with a with an effluent filter in
the outlet tee of the tank. Effluent w¡f I gravity flow to a distribution box set level with access to
grade that will distribute effluent to 672 ft2 of STA. The new 5TA will consist of one chamber bed
with four rows of Quick4 chambers with 14 chambers per row (56 chambers total). lnspection ports
are to be ínstalled at each corner of the bed. Mainta¡n all setbacks and elevations as designed.
Contact the designer and Garfield County Publk Health at least 4E hours priorto requesting ñnal
inspection of the installed system priorto backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above'
ln consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erect¡on,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumpt¡on of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit'
Permit APProval
plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County oWTs Regulation. This Permit will expire 1 year from
the date of issuance unless construct¡on on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
Ir-
lssued By: Garfield CountY Environ Health
De ment
05/Ls/2A2t
Date