HomeMy WebLinkAboutOWTS MaterialsItem # ilut lo60-2GP 1060 Gallon Tnro Gompartment lnfiltrator@ Poly Tank IT'Top View TANK TOP HALF CONTINUOUS GASKET 61u¿', TANK INTERIOR SEAM CLIP (ô4) ALIGNMENT DOWEL (34) TANK BOTTOM HALF Mid-Height Seam Section z4'ACCESSOFENING\Section View Tank lndudes llds 51.T', I 17'11'OUTLET IT' o Compliont with CSA ond IAPMO Stondordsr PVC risers ovoilobler Secondory sofety screen ovoiloble with PVC riser r Moximum buriol depth is 48" o Minumum buriol depth is 6"o Tonk is not roted for vehiculor troffic loodinge Exterior of monhole cover includes the following worning: "DANGER DO NOT ENTER: POISON GASES,' 54.7 EXTERIOR HEIGHT SEAM CLIP (TYPTCAL) LIFTING STRAP (TYPTCAL) End View ln vert ffir,rr*fJr*' ¡Írn [ilsüsla/BlE \ \o o FO o o\ \o f" Bulkhæd Digging Specs Net Copocity Weight 12' Long x 7' Wide lnlet 47" Outlet 44" Length 127" width 62.2" Dimensions 54.7" Heigh 1094 gol 320 lbs Water & Wasüewaúer ¡ S)ætems ¡ Prcducts InG. o Servlce (219) 395{704 2flrFco Rd'317 P.O.Bo(@5 Fax (t19)gg+g7n B¡sEVlsh æ81211 Webelb: wwrv.valle¡prccast ænr Emll : fronüæk@valle¡ryrecastæmn PRECAST, Residential Biotube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drain fi elds. 4-in. (100-mm) Biotube Effluent Fiber 4-in. (100-mm) Biotube Jr. (4-in. Biotube cartridge auail- able separateþ as Insert Fiher) .: 9-in. (200-mm) Base Inlet Fiber 4-in. (100-mm) Insert Filter t t aa 1 1Ia a- , t a ? ,. , 't z : t I I ,. Orencoi superior efiluentfilters resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mrn) Biotube Effluent Fiher prouides maximum long-term ?rotection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard model, has more fhering capacity than the full-sized f'hers sold by other manufacturers. For tan/es with existing ourlet tees, the Biotube Insert Fiber is ideal. Andþr low-profle tanþs, there's the Base Inlet Fiher. * Covered by parent tunbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "l)istributor Locator. " APS.FT-1 Bev.3.4 @ 11/10 0renco Systems@, lnc. . Has 5-i0 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal Standard Features & Benefits . Easyto clean by simply hosing off whenever the tank needs pumping . Removes about two-thirds of sus- pended solids, on average, extending drainfield life . Corrosion-proof construction, to ensure long life . Lifetime warranty 0ptional Features & Benefits . Alarm available, to signal the need for cleaning . Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time . Custom and commercial sizes availa ble Biotube Filtering Pro,c,e,s.g Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. 0renco Systems" lrrcorporaled ()ltangitg tlx \Yíry ite Wo rld D o es Wtl¡ te¿u¡t tere $rww,of éflco,coill *.-¡ â*; € Nomenclatures 4-in. Biotube Filter (standard) FT 04 4-in. Biotube Effluent Fitter Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube@ filter cartridge Solid b Filter housing 4-in. Biotube Jn Tank wall --r- I Options: Blank = no optionsM = flow modulation plate installedA = float bracket attached Cartrldge height: 28" and 36" are standard Houslng height: 36" and 44" are standard Filter dlameter (inches) W = fits Type 3034 outlet plpe S =fits Schedule 40 outletpipe Blank = 1/S" filtrationP = 1/16" filtration Biotube effluent filter series 8-in. Biotube Filter (base inletmodel) FT 0822-14 B 0ptions:A = lloat bracket FS = 2" outlet orifice FSo = 2" outlet orifice and overflow plate- Riser wall Base inlet model Cartridge height: 14" standard Housing height: 22" standard Filter diameter (inches) 08=8" Blank = 1/8" filtrationP = 1/16" flltration Biotube effluent fllter series i Also available w¡th coupling and sleeve as a "kit': FI-0VERFL0WKIT 4-in. Biotubê Jf. fincludes carû¡dge and housing) FTJ 04 18 t 0ptions: Blank = no opt¡onsM = flow modulation plate installedA = float bracket altached Cartridge height(inches) Filter diameler (inches) W = fitsType3034outletteeS = lits Schedule 40 oullet tee 4-in. Biotube Filter lnsert (carÍidse only) FT ¡n04 18 -!- Junior series Biotube effluent filter series Blank = 1/8" filtrationP = 1/16" filtrat¡on Cartr¡dge height (inches) Filler diamet8r (lnches) Blank = 1/8" filtrationP = 1/16" filtration T -To.*rrtomized options (e,g., NC I indicates North Carolina regions) I W = t¡ts type g034 outlet tee S = fits Schedule 40 outlet tee lnsert Biotube effluent filter series Distributed By: Double Walled PVG Riser & L¡d Options Poly Lid (Static load tested to 5000lbs). Skid resistanæ surface. Available in green. Highest level of UV Protection induded. lncludes a foam gasket for airtight and watertight appl ications. lncludes square drive screws to discounage unauthorized enüy. lnsulation panels achieve R-10 insulation nating 2'of lnsulation Standard Orenco @ DuraFiberm Access Lids (FLD) Not recommended for vehicr¡lar üaffi c 24'and 30'Diameters. Solid,resin-infusedfiberglassoonstt¡ction. 20,00G1b breaking süength. Standard green or broum oolors¡ Available with orwithout urethane lid gasket¡ Available with carbon filhationo 4 strainless steel flathead socket cap scrcns & hex keywrench. lnsulated lids available - 2'or4' Double Walled PVC Riser . Available in 2{ and 30" Diameter. Gut to lengür. Sold in +l- 2' incremenß. Must be cut betweon ribs Ø PRTCASI¡Inc. ¡seuce (719) 3956704 2flXþOo Rd3l7 P.O. Bo(æ5 Farc (719)gg+37n B¡m\n$a' @81211 Webelb: rurw.valleyprccastæm Emall : fonüesk@wlle¡ryrccastæm Water & Wa¡ûewaûer . Systems ¡ Prcductts Item # llu-540-HH IIUI-54O lnfiltratoñÐ Poly Tank with l{igh Head Pump W¡dür 61.7 End View TAI{KTOP HA¡.F ooNnNuous GASIGT TANK INTERIOR SEAI' CUP al.6'Allct{liENT ÍþWEL TAI{KBOTTOTI I{A¡.F SEAM CUP fiYrrc¡¡-) LFNNGSIRAP (rY?¡cAL) Mid-Height Seam Section Wires Pand Section View Disænneci Valw 4 DESIGN NOTES¡ Compliont with CSA ond IAPMO Stondordso Secondory sofety screen ovoiloble with PVC Riser¡ Delivered complete with internol piping o Moximum buriol depth is 48"¡ Minimum buriol depth is 6"¡ Tonk is not roted for vehiculor troffic looding¡ Exterior of monhole cover includes the following worning: "DANGER DO NOT ENTER:POISON GASES" al.6' tengût NOTE TANK Þ(IENC'R WDTH I8 61.7 *Servl¿p æntncls available for malntenanæ.* 552 gollons lffir,nr*J,gnl tãtr fil3nËßrr. Digging Specs lnvert Dimensions Net Copocity Weight 6' Long x 6' Wide 47" below inlet invert lnlet 47" Outlet 61" Length 64.9" width 61.7" Height 78.6"369 lbs Water & Wasüewaûer o Systems o Prcducß Frg) 395{704 2gXXtOo' Rd3l7 P.O. Bo(æ5 Farc ffi9)gg+g727 B¡trE\ßb' @81211 Webslb: u,ri il.valloypr€castæÍr Emll : fronüeok@valle)ryrccastærnØ PRTCASIT¡Inc. osemce Biotube@ ProPak Pump PackagerM Orenco TeîhrrlsæI Ðatu *Ítsd 60-Hz Series Pump Packages Control panel General Orenco's Biotube@ ProPaK" is a complete, integrated pump package for filtering and pumping effluent from septic tanks. And its patented pump vault technology eliminates the need for separate dosing tanks. This document provides detailed information on the ProPak pump vault and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel. For more informalion on other ProPak components, see the following 0renco lechnical documents: o Float Switch Assemblies (NSU-MF-MF-1) . Discharge Assemblies (NTD-HV-HV-1 ). Splice Boxes (NTD-SB-SB-1) o External Splice Box (NTD-SB-SB-1) Applications The Biotube ProPak is designed to filter and pump effluent to either gravity or pressurized discharge points. lt is intended for use in a septic tank þne- or two-compartment) and can also be used in a pump tank. The Biotube ProPak is designed to allow the effluent filter to be removed for cleaning without the need to remove the pump vault or pump, simpli- fying servicing. Complete packages are availabb for on-demand or timed dosing sys- tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 Usec), as well as with 50 Hz and 60 Hz power supplies, Standard Models BPP2ODD, BPP2ODD-SX, BPP3OTDA, BPP3OTDD-SX, BBPPsOTDA, BPPSOTDD-SX Product Gode Diagram BPP It t- Standard options: Blank = 57-in. (1448-mm) vault height, inlernal splice box, standard discharge assembly68 = 68-in.(1727-mm)vaultheight SX = external splice box CW = coldweatherdischargeassembly DB - drainback discharge assemblyQ = cam lock MFV = non'mercuryfloat Control panel application: DD = demand-dosing TDA - limed-dosing, analog timer TDD = timed dosino, dioital limer, elapsed t¡me meter & counters Pump fiow rate, nominal: 20 = 20 gpm 30 = 30 gpm 50 = 50 gpm Biotube@ ProPak'" pump External splice box (0ptional; internal splice box comes standard.) Riser lid (not included) Float Riser (not included) Discharge assembly Pump liquid end Pump motor bracket Support pipe Pump vault Float stem Floats Float collar Vault inlet holes 4-in. (100-mm) turbine effluent pump Biotube@ filter cartridge t BiotubP ProPaRrM pump package components. (1.3 Usec) (1.9 Used (3.2 Usec) vault I l Orenco Systems@ lnc, , 814 A¡rway Ave., Sutherlin, 0R S7479 USA . 800-348-9843 . 541-459-4449. www.orenco.com NTD-BPP-l Rev.1.2, @ 08/14 Page 1 of 4 ProPaK' Pump Vault Biotube@ Filter Gartridge Materials of Construction Materials of Construction Vault body Polyethylene Filter tubes Polyethylene Support pipes PVC Cartridge end plates Polyurethane Dimensions, in. (mm)Handle assembly PVC A - Overall vault height 57 (1448) or 68 (1727) Dimensions, in. (mm) B - Vault diameter 17.3 (439)A - Cartridge height 18 (457) C - lnlet hole height 19 (475)B - Cartridge width 12 (305) D - lnlet hole diameter (eight holes total)2 (50)Perlormance E - Vault top t0 supp0rt pipe bracket base 3 (76)Biotube@ mesh opening 0.125 in. (3 mm)- I F - Vault bottom t0 filter cartridge base 4 (1021 D AC -r E B ProPakrM pump vault (shown with Biotube Íilter and effluent pump) Total filter flow area 4.4ft'?(0.4n'?) Total filter surface area 14.5 ft'? (1 .35 m'z) Maximum flow rate 140 gpm (8.8 Usec) -0.062-in, (1.6-nm) f¡lter nesh ava¡lable F_ B ___l BiotubP filter cartridge (shown with float switch assembly) E T A NTD-BPP.1 Bev.1.2, @ 08/14 Pdge2ol 4 orenco Systems@ lnc. , 814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 . 541 -459-4449 . wwworenco.com Teehn'ieal &,ffi $fieef OrenCO 4-in. (100-mm) Turbine Etfluent Pumps Orenco's 4-in. ('100 mm)Turbine Effluent Pumps are constructed of lightweight, corrosion-resistant stainless steel and engineered plastics; all are field-serviceable and repairable with common tools. All 60-Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, and meet UL requirements. Power cords for Orenco's 4-in. (100-mm) turbine effluent pumps are Type S00W 600-V motor cable (suitable for Class '1, Division .1 and 2 applications). Materials of Construction Discharge:Stainless steel or glass{illed polypropylene Dischargebearing: Engineeredthermoplastic(PEE}() Diffusers:Glass{illed PPO lmpellers:Acetal (20-, 30-gmp), Noryl (50-gpm) lntake screens:Polypropylene Suction connection: Stainless steel Drive shaft:300 series stainless steel Coupling:Sintered 300 series stainless steel Shell:300 series stainless steel Lubricant:Deionized water and propylene glycol Specifications Pump Gurves Pump curves, such as those shown here, can help you determine the best pump for your system. Pump curves show the relationship between flow (gpm or Usec) and pressure [DH), providing a graphical representation of a pump's performance range. Pumps perform best allhetr nominalflow rate, measured In gpm or Usec. 0.63 FIow in liters per second (Usec) 1.26 1.89 2.52 3.t5 3.79 4.42 Flow in gallons per ninute (gpn) 140 oe r20 Ë'* !a ë80 IJ'= Eoo\È (! ,E 40 43 eqts¡E soS R È24¡Èei€o 18È \È 12ì Ê 20 Nom, flow, gpm (Usec) Length in. (mm) Weight lb (ks) Díscharge lmpellers in., nominal 1 10 20 30 40 50 60 70 20 (1 ,3) 22.5 (572) 26 (1 1) 1 .25 4 30 (1.9) 21.3 (541) 25 (11) 1.25 J 50 (3.2) 20.3 (516) 27 (12) 2.00 2 Performance Nom. flow, hp (kW) gpm (Usec) Design flow amps Rated cycleVday Min liquid level, in. (mm) 2 20 (1.3) 0,5 (0.37) 12.3 300 18 (457) 30 (1.9) 0.5 (0.37) 11.8 300 20 (508) 50 (3.2) 0.5 (0.37) 12j 300 24 (610) 1 Discharge ¡s female NPT threa(led, U.S. nom¡nal s¡ze, to acconmodate 1rencP d¡scharge hose and valve assenbl¡es. Consult y1ur )renc1 Distr¡butor about f¡ttings to connect d¡scharge assembl¡es to metric-sized p¡p¡ng. 'z M¡ninum liquid level ¡s fu s¡ngle punps when installed in an 1rencoB¡otubæ ProPakrM Punp Vault. .,.a \ I PF t \ ì \\ PF \\ \ I I orenco Systems@ lnc, ,814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-¡1449 . www.orenco.com I'ITD-BPP-1 Rev.1,2, @ 08/14 Page 3 of 4 Control Panel (Demand Dose)Gontrol Panel (Timed Dose) 0renco's ProPaK" demand dose control panels are specifically engineered for the ProPak pump package and are ideal for applications such as demand dosing from a septic tank into a conventional gravity drainfield. Materials of Construction 0renco's ProPak timed dose control panels are specifically engineered for lhe ProPak pump package and are idealfor applications such as timed dosing from a septic tank into a pressurized drainfield or mound. Analog or digital limers are available. Materials of Construction Enclosure UV-resistant fiberglass, UL Type 4X Enclosure UV-resistant fiberglass, UL Type 4X Hinges Stainless steel Hinges Stainless steel Dimensions, in. (mm)Dimensions, in. (mm) A - Height 11.5 (290)A - Height 11.5 (290) B - Width 9.5 (240)B - Width e.5 (240) C - Depth 5.4 (135)C - Depth 5.4 (135) Specifications Specifications Panel ratings 120V,314 hp (0,56 kV\4,144, single phase,60 Hz Panelratings 120V,3/4 hp (0.56 k\Â4,14A, single phase,60 Hz 1, Motor-start contactor 16 FLA, t hp (0.75 kW),60 Hz;2.5 million cycles at FLA (10 m¡ll¡on at 50% of Fl-A) 2. Circuit 120 V, 10 A, 0FF/0N switch, Single pole breakers 3. Toggle switch Single-pole, doublelhrow HOA switch, 20 A 4. Audio alarm 95 dB at 24 in. (600 mm), warble{one sound, UL Type 4X 5. Audio alarm 120 V automatic reset, DIN rail mount silence relay 6. Visual alarm 718-in. Q2-mm) diameter red lens, "Pushlo-silence," I 20 V LED, UL Type 4X Control panel, demand-dose Dual-mode Programmable for timed- 0r demand-dos¡ng (digital timed-dosing panels only) 1 20 V, repeat cycle from 0.05 seconds to 30 hours. Separate variable controls for OFF and 0N time periods 120-V programmable logic unit with built-in LCD screen and programming keys. Provides control funclions and timing for panel operalion 2. Motor-start contactor 16 FLA, t hp (0.75 kW),60 Hz; 2.5 million cycles at FLA (10 million at 50% of Fl-A) 3. Circuit breakers 1 20 V 10 A, 0FF/0N switch. Single pole 1 20 V 4. Toggle Switch Single-pole, doubleìhrow HOA switch, 20 A 5. Audio alarm 95 dB at 24 in. (600 mm), warble{one sound, UL Type 4X 6. Visual alarm 7 /9-in. Q7-nn) diameter red lens, "Push{o-silence", 1 20 V LED, UL Type 4X Control panel, timed-dose (digital timer model shown) 1a. Analog timer (not shown) I b, Digital timer (shown below) o @ ffio ø @re t'lfD-BPP-1 Rev.1.2, @ 08/14 Page 4 of 4 orenco Systems@ Inc.,814 Airway Ave., Sutherlin,0R 97479 USA . 800-348-9843 . 541-459-4449 . www.orenco.com PF Series 4-inch (1 00-mm) Submersible Etfluent Pumps fu&çrÍcal gæ$IredOrenco Applications Our 4-inch (100-mm) Submersible Effluent Pumps are designed to transport screened effluent (with lowTSS counts) from septic tanks or separate dosing tanks. All our pumps are constructed of lightweight, conosion-resistant stainless steel and engineered plastics; all are field- serviceable and repairable with common tools; and all 60-Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, meeting UL requirements. 0renco's Effluent Pumps are used in a variety of applications, including pressurized drainfields, packed bed filters, mounds, aerobic units, effluent inigation, effluent sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube@ pump vault or after a secondary treatment system. - Discharge Connection - Bypass 0rifice Franklin Liquid End - Suction Connection Franklin Super Stainless Motor Featu res/Specif ications To specify this pump for your installation, require the following: ¡ Minimum Z4-hour run-dry capability with no deterioration in pump life or performance* ¡ Patented 1Æ-inch (3-mm) bypass orifice to ensure flow recirculation for motor cooling and to prevent air bind . Liquid end repair kits available for better longlerm cost of ownership r lffl-$fifflrv floating impeller design on 10, 15, 20, and 30 gpm (0.6, 1.0, 1.3, and 1.9 Usec) models; floating stack design on 50 and 75 gpm (3.2 and 4,7 Usec) models . Franklin Electric Super Stainless motor, rated for continuous use and frequent cycling . Type S00W 600-V motor cable . Five-year warranty on pump or retrofit liquid end from date of manu- facture against defects in materials or workmanship . N1t applicable for '-hp (3.73 kW) nodels Standard Models See specifications chart, pages 2-3, for a list of standard pumps. For a complete list of available pumps, call 0renco. Product Gode Diagram PF t _l t .+Cord length, Blank = 1030 =30 ft (m) (3) (e) 20 = 20 (6') 50 = 50(1s) Voltage, nameplate: 1 = 115. 200 = 2002=230t 4 =460 60 Hz 60 Hz 5 = single-phase 50 Hz Frequency: 1 = single-phase 3 = three-phase 05 -- 1/2hp 10=1hp 20 = 2hp 50 = shp Horsepower (kVV): 03 = %hp(0.25) 07=%hp(0.s6) 15 = 1-lzz hp (1.1 30 = 3hp(2,24) 1) (0.37) (0.75) (1.50) (3.73) Nominal flow, gpm 10 = 10(0,6) 20 = 20 (1.3) 50 = 50 (3.2) (Usec): 15 = 15(1.0) 30=30 75=75 (1.e) (4.71 "(D:. @ LH80S80 LFì2053496 Powered by Franklin Electric Pump, PF Series - 1á-hp (0,37kW) only Ì220 volts for 50 Hz pumps rNotei 2oJoot cords are available only for single-phase pumps through 1 -1á hp orenco Systems@ lnc. ,814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 o 541-459-¡1449 . www.orenco.com NTD.PU-PF-l Rev.2,2, @ 09/14 Page 1 of 6 Specifications,60 Hz o =oÉt(tø -9 E ELEt .EI' ı6aho\a-v GE øo,o o Eo (sÉ 6-v s Êtto = o o !t3Ê EV =.E c E 'a Et o o_'ä¡gE ËE U'=¡-Ë Ø 0, q, ÊL Ê ah ÉL Etgx.E = =-9 .P g. (l,tsÊl 6 al)Ø s! ô. (t'Et6(l) :!=6Y Ë-Ë É5E P Pump Model PF10051 1 10 (0.6) 0.50 (0.37) 1 1 15 120 12.7 12.7 6 1 1z¿ in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF1 0051 2 10 (0.6) 0.50 (0.34 1 230 240 6.3 6.3 6 1 /¡ in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF10053200 10(0.6) 0,50(0.34 3 200 208 3.8 3.8 6 11/tin.GFP 23.0(660) 16(406) 26(12) 300 Pt10071245 10 (0,6) 0.75 (0.56) 1 230 240 8.3 8.3 B I /¿ in. GFP 25.9 (658) 17 (4321 30 (14) 300 PF10073200 4,5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 /¿ in. GFP 25.4 (645) 17 (432) 31 (14) 300 PF10101 2 5,6 10 (0.6) 1 .00 (0,75) 1 230 240 9.6 9.6 I 1 /¿ in. GFP 27 .9 (09]' 18 (454 33 (15) 100 PF10103200 16 10 (0.6) 1 .00 (0.75) 3 200 208 5.5 5.5 9 1 1z¿ in. GFP 27.3 (693) 18 (454 37 (n 300 Pt102012qq7,8 10(0.6) 2.00(1.49) 1 230 240 12j 12.1 18 1/¿in.SS 39.5(1003) 22(559) 48Q2) 100 PF1020325,6'B 10(0.6) 2.00(1.49) 3 230 240 7.5 7.6 18 11l¿in.SS 37.9(963) 20(508) 44(20) 300 PF102032005,6,8 10(0.6) 2,00(1.49) 3 200 208 8.7 8.7 18 1%in.SS 37.9(963) 20(508) 44(20) 300 15 (1 .0) 0.33 (0.25) 1 1 15 120 8.7 8.8 3 1 1/¿ in. GFP 19.5 (495) 15 (380) 23 (10) 300PFi 5031 1 PF'l50312 PF20051 1 15 (1 .0) 0.33 (0,25) 1 230 240 4.4 4.5 3 1 1/¿ in. GFP 19.5 15 (380) 23 (10) 300 20 (1 .3) 0.50 (0.34 1 1 15 120 12.3 12.5 4 1 lq in. GtP 22.3 (566) 18 Ø5n 25 (1 1) 300 PF200512 20 (l .3) 0.50 (0,34 1 230 240 6.4 6.5 4 1 lq in. GFP 22.5 (572) 18 Ø5n 26 (2) 300 PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 1/¿ in. GtP 22.3 (566) 18 Ø5n 26 (2) 300 PF201012 4'5 20 (1 .3) 1 .00 (0.75) 1 230 240 10.5 10.5 7 1 /¿ in. GtP 28.4 (t21) 20 (508) 33 (15) 100 PF201 03200 4'5 20 (1 .3) 1 .00 (0.75) 3 200 208 5.8 5.9 7 1 lq in. GtP 27 .8 (06) 20 (508) 33 (1 5) 300 PF201512 4,5 20 (1 ,3) 1 .50 (1 .1 1) 1 230 240 12.4 12.6 9 1 % in. GFP 34.0 (864) 24 (610) 41 (19) 100 PF201 53200 4,5 20 (1 ,3) 1 .50 (1 .11) 3 200 208 7 .1 7 .2 I 1 1/q in. GFP 30.7 (780) 20 (508) 35 (16) 300 30(1.9) 0.50(0.34 1 115 120 11.8 11.8 3 112¿in.GFP 21.3(541) 20(508) 28(13) 300PF30051 1 PF30051 2 30 (1.9) 0.50 (0.34 1 230 240 6.2 6.2 3 1 /¿ in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF30053200 30 (1.9) 0.50 (0.34 3 200 208 3.6 3.6 3 1 /¿ in. GFP 21.3 (541) 20 (508) 25 (11) 300 30 (1 .9) 0,75 (0.56) 1 230 240 8.5 8.5 5 1 % in. GFP 24.8 (630) 21 (533) 29 (13) 300Pt300712 PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 lz¿ in. GFP 24.6 1625) 21 (533) 30 (14) 300 PF301 012 4 30 (1 .9) 1 .00 (0,75) 1 230 240 1 0.4 10,4 6 1 /¿ in. GFP 27.0 (686) 22 (559) 32 (15) 100 PF301032004 30(1.9) 1.00(0,75) 3 200 208 5.8 5.8 6 1/+in.GFP 26.4(671) 22(559) 33(15) 300 PF3015124,5 30(1.9) 1.50(1.11) 1 230 240 12.6 12.6 B 1/¿in.GFP 32.8(833) 24(610) 40(18) 100 PF301532004,5 30(1.9) 1.50(1.11) 3 200 208 6.9 6.9 I 1/¿in.GFP 29.8V\n 22þ59) 34(15) 300 PF3015344,5 30(1.9) 1,50(1.11) 3 460 480 2.8 2.8 8 1/¿in.GFP 29.5(685) 22(559) 34(15) 300 PF3020125'6'7 30(1.9) 2.00(1,49) 1 230 240 11.0 11.0 10 1/¿in.SS 35.5(902) 26(660) 44Q0) 100 PF302032005'6 30(1,9) 2.00(1.49) 3 200 208 9.3 9.3 10 1 /¿in.SS 34.0(864) 24(610) 41 (19) 300 PF3030125,6'7,8 30(1.9) 3.00Q.23) 1 230 240 16.8 16.8 14 1/¿in.SS 44.5(1130) 33(838) 54(24) 100 PF303032 5' 6' I 30 (1 .9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 /¿ in. SS 44.3 (1125) 27 (686) 52 Q4) 300 PF30501 2 5' 6' 7, B 30 (1 .9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 /¿ in. SS 66,5 (1 689) 53 (1 346) 82 ßn 1 00 PF3050325,6'8 30CI.g) 5.00(3.73) 3 230 240 16.6 16.6 23 1/¿in.SS 60.8(1544) 48(12191 66(30) 300 PF305032005'6,8 30(1.9) 5.00(3.73) 3 200 208 18.7 18.7 23 1%in.SS 60.8(1544) 48(1219) 66(30) 300 PF50051 1 50 (3.2) 0.50 (0.37) 1 'l 15 120 12.1 12j 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF50051 2 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500532 50 (3.2) 0.50 (0.34 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF50053200 50 (3.2) 0,50 (0.34 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 50 (3.2) 0.50 (0.34 3 460 480 1 .5 1 .5 2 2 in. SS 20.3 (516) 24 (610) 28 (i 3) 300PF500534 PF5007 1 2 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300 PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23J þ8n 26 (660) 32 (15) 300 I'lTD-PU-PF-f Rev.2.2, @ 09/14 Page 2 of 6 orenco Systems@ lnc. , 814 Airway Ave,, Sutherlin, 0R 9747S USA o 800-348-9843 . 541 -459-4449 . wwlr,,orenco.com Technieal tlata theçt OrenCO Specifications, 60 Hz (continued) ÉlE) o =oÊto¡eC'I.v -=¡ oø6cl\ ıE øa¡'¡5 o!to (gÉ Ðll .ll Ët, 6' = o o E =â.:¿ E EV =.= EÊ ÞEtÉo 6)-.äe sÞËs o-ø=¡5Ë 6 -fPoct È u,ÊL asx6 = IorÊ .s,2ø=(¡)tsE¡6 É)tt s¡È €ãsËsz,t 6'E)G o E o PF500734 50 (3.2) 0.75 (0.56) 3 460 480 1 .8 1 .8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300 Pump Model PF501 01 2 PF501 034 PF505012 5,6'7'8 50 (3.2) 5.00 (3.73) 1 230 240 262 26.4 13 2 in. SS 65.4 (1661) 55 (1394 64 Qg) 300 50 (3.2) 1 .00 (0.75) 1 230 240 10.1 1 0.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 PF50103200 50 (3.2) 1 .00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300 50 (3.2) 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300 PF50151 24 50 (3.2) 1 .50 (1 .1 1) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100 PF501532004 50(3.2) 1.50(1.11) 3 200 208 7.0 7.0 5 2in.SS 29.3(744) 26(660) 35(16) 300 PF50301 2 4,5' 7' I 50 (3.2) 3.00 (2.23) I 230 240 17 .7 17 .7 I 2 in. SS 43.0 (1 092) 37 (940) 55 (25) 1 00 PF50303200 4'5'8 50 (3.2) 3.00 (2.23) 3 200 208 13.1 .13.1 B 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300 PF503034 4,5'8 50 (3.2) 3.00 (2.23) 3 460 480 5.3 5.3 I 2 in. SS 40,0 (1016) 31 (tïn 55 €5) 300 PF505032 5,6'7'8 50 (3.2) 5.00 (3.73) 3 230 240 1 6.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 Q9\ 300 PF751012 75 Ø.n 1 .00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100 Pt751512 75 ø.n 1 .50 (1 .1 1) 1 230 240 12j 12.3 4 2 in. SS 33.4 (848) 30 V62) 44 (20) 100 Specifications, S0 Hz Pump Model PF100752 4,5 10 (0.6) 0.75 (0.56) 1 220 230 6.2 6.2 9 1 /¿ in, GFP 26.8 (658) 17 (432) 30 (14) 300 PF100552 1 0 (0,6) 0.50 (0.34 1 220 230 3.9 4.1 6 1 la in. GFP 23.0 (584) 17 (432) 26 (12) 300 PF101552 r 6 10 (0.6) 1 .50 (1 .1 1) 1 220 230 10.5 11.4 18 1 /¿ in. SS 39.5 (1003) 22 (559) 46 Q|) 300 PF300552 30 (1 .9) 0.50 (0.34 1 220 230 4.1 4.1 4 1 % in. GFP 22.5 (572) 19 (483) 26 (12) 300 PF300752 30 (l .9) 0.75 (0.56) 1 220 230 6.1 6.1 5 1 % in. GFP 24.8 (630) 1 9 (483) 29 (1 3) 300 PF301 052 30 (1 .9) 1 .00 (0.75) 1 220 230 7 .4 7 .4 7 1 1/t in. GFP 28.4 (721) 20 (508) 32 (15) 100 50 (3.2) 0.50 (0.37) 1 220 230 4.0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300 PF3015524'5 30(1.9) 1,50(1.11) 1 220 230 9.3 9.3 8 1lqin.GFP 35.4(899) 24(610) 40(18) 100 PF500552 PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6.3 6.4 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF501 052 50 (3.2) 1 .00 (0.75) 1 220 230 7 .3 7 .4 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 PF501 552 50(3.2) 1.50(1.11) 1 220 230 9.1 9.1 5 2in.SS 32.5(826) 30(762) 42(19) 100 PF751052 75 (3.2) 1 .00 (0.75) 1 220 230 7 .3 7 .3 4 2 in. SS 30.0 (762) 27 (686) 34 (15) 100 D¡stt¡butor about f¡tt¡ngs to connect hose and valve assenbl¡es to metilc-sÞed pip¡ng. 0renco for morc ¡nfomat¡on. 3 We¡ght includes cafton and 10-ft (3-m) cord. 4 High-pressurc discharge assenbly requircd. 5 Do not ße canJock opti1n (8) on discharge assenbly. 6 Custon d¡scharge assenbly requircd for these punps. Contact 0renco. 7 Capacitor pack (s1ld separately or installed ¡n a custon contrcl panel) requ¡red for this punp. Contact 0renco. 8 Iorque locks are ava¡lable Íor all pumps, and are suppl¡ed with 3-hp and 5-hp punps. NTD-PU-PT-f Rev.2.2, @ 09/14 Page 3 of 6 orenco Systems@ lnc, , 814 A¡rway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449. wwworenco.com Orenco FeÊhfüçat Ð#a $åeef Materials of Gonstruction Discharge Glass{illed polypropylene 0r stainless steel Dischargebearing Engineeredthermoplastic(PEE$ Diffusers GlassJilled PPO (Noryl GFN3) lmpellers Celcon@ acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3 lntake screen Polypropylene Suctionconnection Stainlesssteel Drive shaft 7 116 inch hexagonal stainless steel, 300 series Coupling Sintered stainless steel, 300 series Shell Stainless steel, 300 series Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically sealed molor housing ensures moisture{ree windings. All thrust absorbed by Kingsbury-type thrust bearing. Baled for continuous duty. Single- phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp (1 .1 I kW have built-in thermal overload protect¡on, which trips at 203'221' F (95-1 05' C). Using a Pump Gurve A pump curue helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or Usec) and pressure (total dynamic head, or TDH), providing a graphical representation of a pump's optimal performance range. Pumps peform best at their nominal flow rate - the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate pump specification, use 0renco's PumpSelect'" software. Pump Gurves, 60 Hz Models 160 0 140 (¡)ql È 120 R roo È 3Bos C! F60\ :40(È Ê 20 800 700 t¡).ss 600 =fl soo È3 ¿oos() $mo\f zoo(E Ê 100 0246810121416 36912151821 Flow in gallons per minute (gpm) 0 24 Flow in gallons per minute (gpm) PFl0 Series,60 Hz,0.5 - 2.0 hp '., ' i..,., ) PF1005 'r¡¡¡i¡l".,il i.';.'..- -l' I{\\ PFl005-FC wlt/t"llow controller PF|S Series,60 H2,0.3 hp ",\ NTD-PU-PF-1 Rev.2.2, @ 09/14 Page 4 of 6 Orenco Systems@ lnc, ,814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449 . wwworenco.com 900 800 q)* zoo È*o ! soo aJ€t¡ 400 (Es 300È s 200 -o 100 400 350 q) q¡ s 300 f zso È tEq) 200.È o $ rso \I roo(È Ê 50 100 90 ae80 s70s5.60È(E ë50()'È 40t! È30 E20 10 450 400 a)* sso È sooa È 250(Ea (¡ 200'= E rso\ÈÈ roo Ê 50 60 Hz Models (continued) 5101520253035 FIow in gallons per ninute (gpm) 0 10 20 30 40 50 60 70 80 90 Flow in gallons per ninute (gpn) 51015202530354045 FIow in gallons per ninute (gpm) 10 20 30 40 50 60 70 80 90 r00 FIow in gallons per ninute (gpn) 40 0 0 PF30 Series,60 H2,0.5 - 5.0 hp i:'.: ",.,i, '.i'. : " ì 11:: l PF20 Series,60 H2,0.5 - 1.5 hp PF75 Sedes,60 Hz, 1.0 - 1.5 hp \; :l FFEobo PF50 Series,60 H2,0.5 - 5.0 hp "',. ,^''; 0renco Systems@ lnc. , 814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449 . www.orenco.com I'ITD-PU.PF-I Bev.2,2, @ 09/14 Page 5 of 6 Orenco i Tesh*i,çatr Bã*a $fieef Pump Gurves,50 Hz Models 0.1 FIow in gallons per minute7.9 16 24 32 4{) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Flow in liters per second (Usec) Flow in gallons per minute (gpn), noninal63 13 19 25 32 0.4 0.8 1.2 1.6 2.0 Flow in liters per second (Usec) Flow in gallons per minute (gpn), noninal1019N384857677686 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 FIow in liters per second (Usec) Flow in gallons per minute (gpn), noninal9.5 lt 131.6 3.2 43 6.3 7.9 sza E è zoz $ =o rs7 5.È(! 0)so 131 'È (E È ooF 120 100 eqt q¡ È .S 80 F loo(¡¡€(¡ E¿o\È' tÈ Ê 20 525 \ E 459 èÈ È\ es+ $ gzs Ê R zoz Ias rsz'3 E rsr È tÈ .o66h 180 160 es 140 t¡¡ .S lzo =at.rooÈ|! Q¡Ê80 CI'=È SaoS.È g40 Ê 20 89-G 7ss os Ë'qt ssì s ¿s S.È G ssÊ o eoF\zollE Ê 30 27 (âtzq P .È ,' F" È 315Ê 'S rz EÈs (È .o6 (! Èè Þ\(¡)e ìo !Gq¡Ê() G\È lÈ Ê 00 2.400 þpn), 48 nominal56 6Íl 15 98 82 66 49 33 16 45 40 35 30 10 et¡ (¡) .= Èı È(È t¡)s() G\È (E Ê 3 54 6.01.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Flow in liters per second (Usec) 0.5 PF10 Series,50 Hz,0.37 - 1.11 kW PFr005-FC w/6mmflow controller PF30 Series,50 Hz,0.37 - 1.lf kW ". 'i....,. PF75 Series,50 H2,0.75 kWPt50 Series,50 H¿ 0.37 - l.1l kW ffi ...'\ :;J;-.\ ..> l ': NTD-PU-PF-1 Rev.2.2,@ Ogl14 Page 6 of 6 0renco Systems@ lnc. ,814 Airway Ave., Sutherl¡n, 0R 97479 USA . 800-348-9843 . 541-459-4449 . www'orenco.com This article may describe design critería that was in effect at the time the article was written. FOR CURRENT DESIGN CNTENA, call Orenco Systems, Inc. at 1-800-348-9843 Orenco Automatic D¡str Valve Assemblies nutb g ã.-,ñtG For Wastewater Effluent Systems Introduction Orenco's automatic distributing valve assemblies, pressurized with small high-head effluent pumps, are useful for distributing effluent to multiple zones. These zones can be segments of sand filter manifolds, drainf,relds, or other effluent distribution systems. Distributing valve assemblies can substantially simplify the design and installation of a distribution sys- tem and reduce installation costs. This is particularly true where a distributing valve assem- bly is used instead of multiple pumps and/or electrically operated valves. Additionally, a reduction in long term operation and maintenance costs is realized due to a reduced size andlor number of pumps. More even distribution can be achieved on sloping sites by zoning laterals at equal elevations. This eliminates drainback to lower lines and the unequal distrib- ution of effluent that occurs at the beginning of a cycle. Valve Operation The valve itself has only a few moving parts, requires no electricity, and alternates automati- cally each cycle. Refer to Figure 1 for the following valve operation description. The flow of the incoming effluent forces the rubber flap disk O to seat against the valve bottom Ø. The opening @ in the rubber flap disk aligns with an opening in the valve bottom to allow flow to only one valve outlet. The stem @ houses a stainless steel spring which pushes the rubber flap disk away from the valve bottom after the flow of efÍluent stops. The stem acts as a cam follower and rotates the rubber flap disk as the stem is raised and lowered through the cam @. The force from the flow of effluent pushes the stem down through the cam and the stainless steel spring pushes the stem back up through the cam when the flow of effluent stops. Each linear motion of the stem allows the rubber flap disk to rotate half the distance necessary to reach the next outlet. When there is no floq the rubber flap disk is in the "up" position and is not seated against the valve bottom. Figure l: 6000 Series Valve Orenco Systems' I ncorporated 1-800-348-9843 NTP.VA-1 ßev.1.2, @ 11/03 Orenco Syslems@, lnc, Page 1 ol 6 o lnlet -t> @ o ø 0utlets o ,l I Figure 2: 0renco Distributing Valve Assembly (6000 Series Valve) The Distributing Valve Assembly The Orenco Automatic Distributing Valve Assembly combines the distributing valve itself and sever- al other components to give a complete preassembled unit that is easy to install, monitor, and main- tain. Figure 2 shows a complete assembly. Because distributing valves with several outlets can be difficult to line up and glue together in the field, the discharge lines in the assemblies are glued in place at Orenco. The unions (l) allow removal and maintenance of the valve. The clear PVC pipe sections (2) give a visual check of which discharge line is being pressurized. The inlet ball valve (3) allows a quick, simple method to test for proper valve cycling. The ball valve also stops the flow of effluent in case the pump is activated unexpectedly during maintenance or inspection. Check valves may be necessary on the discharge lines. Use of check valves is discussed in the valve positioning section. Valve Assembly Hydraulics Liquid flowing through the valve assembly must pass through fairly small openings and make several changes in direction. Because of this, headlosses through the valve assembly are fairly high. Table I gives the headloss equations for several different assemblies and Figure 3 shows the graphical repre- sentations of these equations. Orenco recommends that high-head turbine pumps be used to pressur- ize the valve assemblies to ensure enough head is available for proper system operation. High-head turbine pumps are also recommended because the use of a distributing valve usually requires more frequent pump cycling. The high-head turbine pumps are designed for high cycling systems and will outlast conventional effluent pumps by a factor of 10 or more in a high cycling mode. Furthermore, the high-head turbine pump intake is 12 inches or more above the bottom of the pump and tends to prevent any settled solids from being pumped into the distribution valve and obstructing its opera- tion. Aminimum flow rate through the distributing valve is required to ensure proper seating of the rubber flap disk. Minimum flow rates for the various models are given in Table 1. NTP.VA-1 Bev.1.2, @ 11/03 orenco Syslemso, lnc. Page 2 of 6 .> -o EoaØ -co, =oL -cl- U) at)oJ !(ItoI Thble 1. Automatic Distributing ValveAssembly Headloss Equations Model Series Equation Operating Range fgrm) VMff,A Hl:o.o85xql.45 10-40 v46004 HL:0.085 x ql'58 rc -25 v6400A H¡:0.0045"d+3.5x(1-e-0.06q ß-70 v6600A H¡:0.0049"d+5.5x(1-"-0.19 ß-70 35 30 25 20 15 10 5 0 35 40 Flow (gpm) Figure 3: Automatic d¡str¡but¡ng valve assembly headloss curves The Pumping System Although the distributing valve was designed for the irrigation industry it has started to gain fairly wide acceptance in the effluent pumping industry. However, because of the mechanical movements of the valve, it is necessary to take steps to prevent solids from reaching the distributing valve that may impede the operation of the valve. Orenco Biotube@ Pump Vaults - when properly sized and installed - provide the necessary protection to prevent valve malfunction. The Biotube@ pump vault accepts effluent only from the clear zone between a tank's scum and sludge layers and then filters this efTluent through a very large surface afea screen cartridge. Without this protection in effluent systems, the valve has very little chance of reliable long-term operation. NTP-VA{ Rev. 1.2, @ 11/03 0fênco Systems@, lnc. Page 3 of 6 051015202530 45 50 55 60 65 70 v66004 ,1 f / v64004 v46004 -/ v44004l-.¿Jd'4 at/- -/êrJttJ /a- -.1 -.ã /4 -á '-t- -..-¿a f,*- tt7 -¿ã 4T Valve Positioning The physical position of the valve in relation to the pump and the discharge point is very important for proper valve operation. The most reliable operation occurs when the valve is placed at the high point in the system and as close to the pump as possible. The transport line between the pump and valve should be kept full if possible. If the line is empty at the beginning of each cycle, pockets of air during filling can cause random rotation of the valve. The valve is particularly vulnerable to this erratic rotation with empty lines that are long and not laid at a constant grade. An ideal valve loca- tion is shown in Figure 4. If the final discharge point is more than about 2 feet above the valve and the system does not drain back into the dosing tank, check valves should be installed on the lines immediately following the valve and a pressure release hole or line should be installed just prior to the valve. This pressure release hole or line can go into a return line to the dosing tank or to a "minidrainfield" near the valve. In order for the valve to rotate reliably, no more than about 2 feet of head should remain against the valve to allow the rubber flap disk to return to its up position. In many cases, it may take from one minute to several minutes for the pressure in the valve to be lowered enough for proper rotation to occur. Special care should be taken when installing systems controlled by programmable timers to ensure cycling does not occur too rapidly. Figure 5 illustrates a valve assembly using check valves. Pumping downhill to the valve should be avoided unless the transport line is very short and the ele- vation between the discharge line out of the tank and the valve is less than about 2 feet. If the valve is located many feet below the dosing tank, random cycling may occur while the transport line drains through the valve at the end of the cycle. A pressure sustaining valve located just before the distrib- uting valve may overcome this problem in some instances. Valve Assembly Discharge Transport Line Dosing Tank Figure 4: ldeal valve location NTP-V4.1 Rev.1.2, @ 11/03 ofenco Systems@, lnc. Page 4 of 6 System Startup Refer to the Hydrotek Valve booklet that is provided with the distributing valve assembly for the sequencing of the valve outlets. The transport line should always be flushed with clean water before installing the valve. Any sand, gravel, or other foreign objects that may have been in the pipe during installation can easily become lodged in the distributing valve, causing malfunction. With the pump running, alternately close and open the ball valve on the distributing valve assembly to check proper rotation of the valve. (Note: If check valves are used on the lines after the distribut- ing valve, the pump may need to be turned on and off to allow the pressure to be released from the valve.) If visual operation of which zone is operating is not possible, watch the clear pipe on each line for indication of which zone is operating. D¡scharge Laterals Pressure Release Line if h>2L0" Valves ¡f h>2L0" Valve Assembly Transport Line Dosing Tank Figure 5: Valve assembly below final discharge point Maintenance Annually check for proper operation by following procedures listed in the Hydrotek Valve booklet and system startup procedures listed above. Troubleshooting 1. PROBLEM: Valve does not change or cycle to next zone oÍ outlet CAUSE:The stem and disk assembly is not rotating when water flow is turned off and then back on. SOLUTION 1: Ensure that there is no debris inside the cam. Clean and carefully reinstall the cam. SOLUTION 2: If fewer than the maximum number of outlets are being used, check the installation of the cam. Ensure that the stem and disk assembly is not being held down by an improperly installed cam. Refer to the cam replacement instructions. NTP-VA.1 Bev.1.2, @ 1U03 0renco Systems@, lnc. Page 5 of 6 SOLUTION 3 SOLUTION 4: SOLUTION 5: SOLUTION 6 Remove the valve top and check for proper movement of stem and disk assembly. Check for and remove any debris or foreign objects that may jam or retard the movement of the disk. Check for freedom of movement of stem and disk assembly up and down over the center pin in bottom of valve. Scale deposits may build up on the pin and hold stem and disk assembly down. Clean pin and again check for freedom of movement. Be sure that all operating outlets are not capped and that the flow to operating zones is not restricted in any manner. This would cause pressure to build up in the valve and lock the stem and disk assembly in the down position. The backflow of water from uphill lines may be preventing the valve from cycling properly. This can happen when the valve is placed too far below an elevated line. If the valve cannot be placed close to the high point of the system, a check valve should be installed near the valve in the outlet line that runs uphill from the valve and a drain line installed just prior to the valve to relieve the pressure. 2. PROBLEM: Water comes out of all the valve outlets CAUSE: Stem and disk assembly not seating properly on valve outlet. SOLUTION 1: Check for sufficient water flow. A minimum flow rate is required to properly seat the disk as shown in Table 1. SOLUTION 2: Remove the valve top and check the inside walls to ensure that nothing is interfering with the up and down movement of the stem and disk assembly inside the valve. SOLUTION 3: Make sure that the operating outlets are not capped and that the flow to the operat- ing zones are not restricted in any manner. 3. PROBLEM: Valve skips outlets or zones CAUSE:Pumping into an empty transport line - especially downhill - may cause the valve to skip outlets from pockets of air allowing the rubber flap disk to raise during a cycle. SOLUTION l: Keep the transport line full. SOLUTION 2: If the line must remain empty between cycles, use a larger diameter transport line laid at a constant grade to prevent air pockets from forming. CAUSE The stem and disk assembly is being advanced past the desired outlet. SOLUTION 1: Ensure that the correct cam for the desired number of zones is installed and that the outlet lines are installed to the correct outlet ports of the valve as indicated by the zone numbers on the top of the cam. t{ïP-vA-1 Rev.1.2, @ l1103 ofenco Syslemso, lnc. Page 6 ol 6 â.-, ñú €Distributing Valves Submittal Data Sheet OrencoSyslemB" lncorporated 1-800-348-9843 Applications Automatic Distributing Valve Assemblies are used to pressurize multiple zone distribution systems including textile filters, sand filters and drainfields. coupling dislributing valve union clear pipe Top View ball valve elbow Side View elbows Bottom View General 0renco's Automatic D¡stributing Valve Assemblies are mechanically operated and sequentially redirect the pump's flow to multiple zones or cells in a distribution field. Valve actuation is accomplished by a combination of pressure and flow. Automatic Distributing Valve Assemblies allow the use of smaller horsepower pumps on large sand filters and drainfields. For example, a large community drainfield requiring 300 gpm can use a six-line Valve Assembly to reduce the pump flow rate requirement to only 50 gpm. 0renco only warrants Automatic Distributing Valves when used in conjunction with High-Head Effluent Pumps with Biotube@ Pump Vaults to provide pressure and flow requirements, and to prevent debris from fouling valve operation. An inlet ball valve and a section of clear pipe and union for each outlet are provided for a complete assembly that is easy to maintain and monitor. ldeal valve location is at the high point in the system. Refer to Automatic Distributing Valve Assemblies (NTP-VA-1) for more information. Standard Models v4402A, V4403A, V4404A, V4605A, V4606A, V6402A, V6403A, v6404A, V6605A, V6606A. Nomenclature A-lìn¿i.ut". assembly Specifications Number of active outlets senes: 44 = 4400series(2-4 outlets) 46 = 4600 series(5-6outlets) 64 : 6400 series(2-4outlets) 66 : 6600 series (5-6 outlets) Distributing valve I Materials of Construction AllFittings: Unions: BallValve: Clear Pipe: V4XXX Distri buting Valves: V6)frX Distributing Valves: Sch.40 PVC perASTM specification Sch.80 PVC perASTM specification Sch.40 PVC perASTM specification Sch.40 PVC per ASTM specification High-strength noncorrosive ABS polymer and stainless steel High-strength noncorrosive ABS polymer; stainless steel, and d¡e cast metal NSU-SF-VA-1 Bev.3.0 @ 4/03 Page 1 of 2 Distributi ng Valves (continued) - :lS à :il¡¡t SEU' .EnEt erE nloo EEtúJq, 0 05r015nÃil:1540455055m6570 Flow(gpm) v66004 v44004l-¿v6400A v46004l-/-t/ -1 á a '--t*ê' -.."ë #7r- Model lnlet Size {in.) Or¡tleb Size (in.} Flow range (gpm} Max Head (ft} Min. Enclosure V4/f,z{1.25 1.25 t0-40 170 vB121t v44034 1.25 1.25 10-40 170 V81217 v44MA 1.25 1.25 10-N 170 VB121t v4605A 1.25 1.25 10-25 170 RR2418 v4606A r.25 1.25 10 - 25 170 RR2418 v6402A 1.5 1.5 15- 100 345 RR2418 v&1034 1.5 1.5 15 - 100 345 RR2418 VEM4A 1.5 1.5 15 - 100 345 RR2418 v66054 1.5 1.5 15 - 100 345 RR2418 v6606A 1.5 1.5 15 - 100 345 RR24r8 itsu-st-vÀ-l Bev. 3.0, @ 4/03 Page 2 ol 2 Dalet 0712412013Shæt 1 of 'lCh€dedby: DFH]EM bY EMBffiINFILTRATOR.¡ìI$tílsìS ifllìINFILTRATOR SYSTEMS INC.4 Business Park Rd. Old Saybrook, CT 06475(800) 2214436QUICK4 PLUS STANDARDLOW PROFILE CHAMBERPRODUCT SPECIFICATIONS€lê: Nor ro sdEINFILTRATOR SYSTEMS INC.QUICK4 PLUS STANDARDLOW PROFILE CHAMBERPRODUCT SPEGIFIGATION(NOT TO SCALE)TOP VIEWQUICK4 PLUS ALL.IN.ONE END CAP10.4' EFFECTIVE LENGTH-INSPECTION PORT8"3.3" INVER' Tl--,r,,-l13.3" EFFECTIVE LENGTH*QU¡CK4 PLUS END CAPf*- ¿.s" EFFEcrtvE LENGTH.8"3.3'' INVERTl--.tt', -J6"SIDE V¡EWEND VIEW48"(EFFECTIVE LENGTH)B"34"-ALL VIEWS ! INSTALLED LENGTHS Dare: 05120120'15Sheet I of 1Jfawn by: EMB IS€ls NorrosdElche*ed by: DFH:tfINFILTRATOPINFILTRATOR WATER TECHNOLOGIES4 Business Park Rd. Old Sâybrook, CT 06475(800) 2214436QUICK4 PLUS STANDARD CHAMBERTYPICAL TRENCH DETAILSECTION VIEWIN FILTRATOR WATER TECH NOLOGIESQUICK4 PLUS STANDARD CHAMBERTYPICAL TRENCH DETAILSECTION VIEW(NOT TO SCALE)PRESSURE PIPËIF REQ'D, PER DESIGNNATIVE BACKFILLTOPSOIL6" COVER12" COVER H-112"8'' INVERT34"SPACING PER CODE34"(36" WDE TRENCH)* LENGTH AND NUMBER OF TRENCHES DETERMINED BY DESIGN Orifice Shields Orenco I TeetrnicaÍ lÌ&athed Applications Orenco@ Orifice Shields are used in a pressurized distribution system to protect the orifices from backfill debris that might cause orifice blockage. '**þ. ¿ â 0rifice shield installed on lateral pipe, standard conliguration Shield 0rifice Cutaway view, standard configuration 0rifice Shield Cutaway view, cold weather configuration General Orenco Orifice Shields snap-fit onto laterals. They may be placed on top of or beneath a lateral, depending on the location of the orifice. Orifice shields are covered by method-of-use patent # 5,360,556. Standard Models 0s075, 0s1 00, 0s1 25, 0s1 50, 0s200 Product Gode Diagram 0s Lateral pipe size, nominal: 075 = 0.75 in. (20 mm) 0rifice shield Material of Gonstruction PVC per ASTM D-1 784 Physical Specifications Model Irc 1\.€Â:_ 100 = 1 .00 in. (25 125 = 1 .25 in. (32 150 = 1.50 in. (40 200 = 2.00 in, (50 mm) mm) mm) mm) Shield 0.D. in. (mm) Lateral pipe 0.0. in, (mm) 0s075 3.5 (8e)1.05 Q7) 0s1 00 3.5 (8e)1 .315 (33) 0s1 25 3.5 (8e)1.66 (42) 0s1 50 4.5 (r14)1.90 (48) 0s200 4.5 (114)2.375 (60) orenco Systems@ lnc, , 814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449 . wwworenco,com NTD-SF-0S-1 Rev.1.1, @ 09/14 Page 1 of 1 ftem# SEK.Orenco@ Flushing Assemblies Flushinq Assemblies Orenco@ flushing assemblies provide easy access for lateral maintenance. Flushing assembly kits include a PVC sweep with ball valve and a polyethylene valve box enclosure. Orenco@ flushing assemblies are avaÍlable in the following sizes:. !" diameter. L25" diametero 1.5" diameter. 2" diameter Valve Boxes Orenco@ valve boxes are used to provide access to flushing assemblies. Constructed of polyethylene. Valve Box, 7-in. diameter round enclosure Note: Kits include VB7 valve box enclosure. t'.-->*o %'%ffi îfRTIEY PREtffST,tnc. Water & Wastewater. Systems. Products. Service (7ts) sss-G7l4 fi:j:ffintY Road 317 Fax: (719) 395-3727 Buena Vista' co 81211 Websiter http ://valleyprecast.com/ Email : frontdesk@valleyprecast.com