HomeMy WebLinkAboutOWTS MaterialsItem #
ilut lo60-2GP
1060 Gallon Tnro Gompartment
lnfiltrator@ Poly Tank
IT'Top
View
TANK TOP
HALF
CONTINUOUS
GASKET
61u¿',
TANK
INTERIOR SEAM CLIP
(ô4)
ALIGNMENT
DOWEL (34)
TANK BOTTOM
HALF
Mid-Height Seam
Section
z4'ACCESSOFENING\Section
View
Tank lndudes llds
51.T',
I
17'11'OUTLET
IT'
o Compliont with CSA ond IAPMO Stondordsr PVC risers ovoilobler Secondory sofety screen ovoiloble with PVC riser
r Moximum buriol depth is 48"
o Minumum buriol depth is 6"o Tonk is not roted for vehiculor troffic loodinge Exterior of monhole cover includes the following
worning: "DANGER DO NOT ENTER: POISON
GASES,'
54.7
EXTERIOR
HEIGHT
SEAM CLIP
(TYPTCAL)
LIFTING STRAP
(TYPTCAL)
End
View
ln vert
ffir,rr*fJr*'
¡Írn [ilsüsla/BlE
\
\o
o
FO o
o\
\o
f"
Bulkhæd
Digging Specs Net
Copocity
Weight
12' Long x 7' Wide lnlet
47"
Outlet
44"
Length
127"
width
62.2"
Dimensions
54.7"
Heigh
1094 gol 320 lbs
Water &
Wasüewaúer
¡ S)ætems
¡ Prcducts
InG. o Servlce
(219) 395{704 2flrFco Rd'317
P.O.Bo(@5
Fax (t19)gg+g7n B¡sEVlsh æ81211
Webelb: wwrv.valle¡prccast ænr
Emll : fronüæk@valle¡ryrecastæmn PRECAST,
Residential Biotube' Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drain fi elds.
4-in. (100-mm) Biotube Effluent Fiber
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge auail-
able separateþ as Insert Fiher)
.:
9-in. (200-mm)
Base Inlet Fiber
4-in. (100-mm)
Insert Filter
t
t
aa
1
1Ia
a-
,
t
a
?
,.
,
't
z
:
t
I
I
,.
Orencoi superior efiluentfilters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mrn) Biotube Effluent Fiher prouides maximum long-term
?rotection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more fhering capacity than the full-sized f'hers
sold by other manufacturers. For tan/es with existing ourlet tees, the Biotube Insert Fiber
is ideal. Andþr low-profle tanþs, there's the Base Inlet Fiher.
* Covered by parent tunbers 5,492,635 and 4,439,323
To Order
Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
"l)istributor Locator. "
APS.FT-1
Bev.3.4 @ 11/10
0renco Systems@, lnc.
. Has 5-i0 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
. lnstalls in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
Standard Features & Benefits
. Easyto clean by
simply hosing off
whenever the tank
needs pumping
. Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
. Corrosion-proof
construction, to
ensure long life
. Lifetime warranty
0ptional
Features &
Benefits
. Alarm available, to
signal the need for
cleaning
. Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
. Custom and
commercial sizes
availa ble
Biotube
Filtering
Pro,c,e,s.g
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes'entire
surface for filtering.
Particles larger than
the Biotube's mesh
are prevented from
leaving the tank.
0renco Systems"
lrrcorporaled
()ltangitg tlx \Yíry ite
Wo rld D o es Wtl¡ te¿u¡t tere
$rww,of éflco,coill
*.-¡
â*;
€
Nomenclatures
4-in. Biotube Filter (standard)
FT 04
4-in. Biotube
Effluent Fitter
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube@ filter cartridge
Solid b
Filter housing
4-in. Biotube Jn
Tank wall
--r-
I Options:
Blank = no optionsM = flow modulation plate installedA = float bracket attached
Cartrldge height: 28" and 36" are standard
Houslng height: 36" and 44" are standard
Filter dlameter (inches)
W = fits Type 3034 outlet plpe
S =fits Schedule 40 outletpipe
Blank = 1/S" filtrationP = 1/16" filtration
Biotube effluent filter series
8-in. Biotube Filter (base inletmodel)
FT 0822-14 B
0ptions:A = lloat bracket
FS = 2" outlet orifice
FSo = 2" outlet orifice and overflow plate-
Riser
wall
Base inlet model
Cartridge height: 14" standard
Housing height: 22" standard
Filter diameter (inches)
08=8"
Blank = 1/8" filtrationP = 1/16" flltration
Biotube effluent fllter series
i Also available w¡th coupling and sleeve as a "kit': FI-0VERFL0WKIT
4-in. Biotubê Jf. fincludes carû¡dge and housing)
FTJ 04 18
t 0ptions:
Blank = no opt¡onsM = flow modulation plate installedA = float bracket altached
Cartridge height(inches)
Filter diameler (inches)
W = fitsType3034outletteeS = lits Schedule 40 oullet tee
4-in. Biotube Filter lnsert (carÍidse only)
FT ¡n04 18 -!-
Junior series
Biotube effluent filter series
Blank = 1/8" filtrationP = 1/16" filtrat¡on
Cartr¡dge height (inches)
Filler diamet8r (lnches)
Blank = 1/8" filtrationP = 1/16" filtration
T -To.*rrtomized options (e,g., NC
I indicates North Carolina regions)
I W = t¡ts type g034 outlet tee
S = fits Schedule 40 outlet tee
lnsert
Biotube effluent filter series
Distributed By:
Double Walled PVG Riser & L¡d Options
Poly Lid
(Static load tested to 5000lbs). Skid resistanæ surface. Available in green. Highest level of UV Protection induded. lncludes a foam gasket for airtight and
watertight appl ications. lncludes square drive screws to discounage
unauthorized enüy. lnsulation panels achieve R-10 insulation nating
2'of lnsulation
Standard
Orenco @ DuraFiberm Access Lids (FLD)
Not recommended for vehicr¡lar üaffi c
24'and 30'Diameters. Solid,resin-infusedfiberglassoonstt¡ction. 20,00G1b breaking süength. Standard green or broum oolors¡ Available with orwithout urethane lid gasket¡ Available with carbon filhationo 4 strainless steel flathead socket cap scrcns & hex
keywrench. lnsulated lids available - 2'or4'
Double Walled PVC Riser
. Available in 2{ and 30" Diameter. Gut to lengür. Sold in +l- 2' incremenß. Must be cut betweon ribs
Ø PRTCASI¡Inc. ¡seuce
(719) 3956704 2flXþOo Rd3l7
P.O. Bo(æ5
Farc (719)gg+37n B¡m\n$a' @81211
Webelb: rurw.valleyprccastæm
Emall : fonüesk@wlle¡ryrccastæm
Water &
Wa¡ûewaûer
. Systems
¡ Prcductts
Item #
llu-540-HH
IIUI-54O lnfiltratoñÐ Poly Tank
with l{igh Head Pump
W¡dür
61.7
End
View
TAI{KTOP
HA¡.F
ooNnNuous
GASIGT
TANK
INTERIOR SEAI' CUP
al.6'Allct{liENT
ÍþWEL TAI{KBOTTOTI
I{A¡.F
SEAM CUP
fiYrrc¡¡-)
LFNNGSIRAP
(rY?¡cAL)
Mid-Height Seam
Section
Wires
Pand
Section
View
Disænneci
Valw
4
DESIGN NOTES¡ Compliont with CSA ond IAPMO
Stondordso Secondory sofety screen ovoiloble
with PVC Riser¡ Delivered complete with internol
piping
o Moximum buriol depth is 48"¡ Minimum buriol depth is 6"¡ Tonk is not roted for vehiculor
troffic looding¡ Exterior of monhole cover includes
the following worning: "DANGER DO
NOT ENTER:POISON GASES"
al.6'
tengût
NOTE TANK Þ(IENC'R WDTH I8 61.7
*Servl¿p æntncls available for malntenanæ.*
552 gollons
lffir,nr*J,gnl
tãtr fil3nËßrr.
Digging Specs lnvert Dimensions Net
Copocity
Weight
6' Long x 6' Wide
47" below inlet invert
lnlet
47"
Outlet
61"
Length
64.9"
width
61.7"
Height
78.6"369 lbs
Water &
Wasüewaûer
o Systems
o Prcducß
Frg) 395{704 2gXXtOo' Rd3l7
P.O. Bo(æ5
Farc ffi9)gg+g727 B¡trE\ßb' @81211
Webslb: u,ri il.valloypr€castæÍr
Emll : fronüeok@valle)ryrccastærnØ PRTCASIT¡Inc. osemce
Biotube@ ProPak Pump PackagerM
Orenco TeîhrrlsæI Ðatu *Ítsd
60-Hz Series Pump Packages
Control panel
General
Orenco's Biotube@ ProPaK" is a complete, integrated pump package for
filtering and pumping effluent from septic tanks. And its patented pump
vault technology eliminates the need for separate dosing tanks.
This document provides detailed information on the ProPak pump vault
and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel.
For more informalion on other ProPak components, see the following
0renco lechnical documents:
o Float Switch Assemblies (NSU-MF-MF-1)
. Discharge Assemblies (NTD-HV-HV-1 ). Splice Boxes (NTD-SB-SB-1)
o External Splice Box (NTD-SB-SB-1)
Applications
The Biotube ProPak is designed to filter and pump effluent to either
gravity or pressurized discharge points. lt is intended for use in a septic
tank þne- or two-compartment) and can also be used in a pump tank.
The Biotube ProPak is designed to allow the effluent filter to be removed
for cleaning without the need to remove the pump vault or pump, simpli-
fying servicing.
Complete packages are availabb for on-demand or timed dosing sys-
tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 Usec),
as well as with 50 Hz and 60 Hz power supplies,
Standard Models
BPP2ODD, BPP2ODD-SX, BPP3OTDA, BPP3OTDD-SX, BBPPsOTDA,
BPPSOTDD-SX
Product Gode Diagram
BPP It t-
Standard options:
Blank = 57-in. (1448-mm) vault height, inlernal
splice box, standard discharge assembly68 = 68-in.(1727-mm)vaultheight
SX = external splice box
CW = coldweatherdischargeassembly
DB - drainback discharge assemblyQ = cam lock
MFV = non'mercuryfloat
Control panel application:
DD = demand-dosing
TDA - limed-dosing, analog timer
TDD = timed dosino, dioital limer, elapsed t¡me
meter & counters
Pump fiow rate, nominal:
20 = 20 gpm
30 = 30 gpm
50 = 50 gpm
Biotube@ ProPak'" pump
External splice box
(0ptional; internal splice
box comes standard.)
Riser lid
(not included)
Float
Riser (not
included)
Discharge
assembly
Pump
liquid end
Pump motor
bracket
Support pipe
Pump vault
Float stem
Floats
Float collar
Vault inlet holes
4-in. (100-mm)
turbine effluent pump
Biotube@ filter
cartridge
t
BiotubP ProPaRrM pump package components.
(1.3 Usec)
(1.9 Used
(3.2 Usec)
vault
I
l
Orenco Systems@ lnc, , 814 A¡rway Ave., Sutherlin, 0R S7479 USA . 800-348-9843 . 541-459-4449. www.orenco.com NTD-BPP-l
Rev.1.2, @ 08/14
Page 1 of 4
ProPaK' Pump Vault Biotube@ Filter Gartridge
Materials of Construction Materials of Construction
Vault body Polyethylene Filter tubes Polyethylene
Support pipes PVC Cartridge end plates Polyurethane
Dimensions, in. (mm)Handle assembly PVC
A - Overall vault height 57 (1448) or 68 (1727) Dimensions, in. (mm)
B - Vault diameter 17.3 (439)A - Cartridge height 18 (457)
C - lnlet hole height 19 (475)B - Cartridge width 12 (305)
D - lnlet hole diameter (eight holes total)2 (50)Perlormance
E - Vault top t0 supp0rt pipe bracket base 3 (76)Biotube@ mesh opening 0.125 in. (3 mm)-
I
F - Vault bottom t0 filter cartridge base 4 (1021
D
AC
-r
E
B
ProPakrM pump vault (shown with Biotube Íilter and effluent pump)
Total filter flow area 4.4ft'?(0.4n'?)
Total filter surface area 14.5 ft'? (1 .35 m'z)
Maximum flow rate 140 gpm (8.8 Usec)
-0.062-in, (1.6-nm) f¡lter nesh ava¡lable
F_ B ___l
BiotubP filter cartridge (shown with float switch assembly)
E
T
A
NTD-BPP.1
Bev.1.2, @ 08/14
Pdge2ol 4
orenco Systems@ lnc. , 814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 . 541 -459-4449 . wwworenco.com
Teehn'ieal &,ffi $fieef OrenCO
4-in. (100-mm) Turbine Etfluent Pumps
Orenco's 4-in. ('100 mm)Turbine Effluent Pumps are constructed of
lightweight, corrosion-resistant stainless steel and engineered plastics;
all are field-serviceable and repairable with common tools. All 60-Hz
PF Series models are CSA certified to the U.S. and Canadian safety
standards for effluent pumps, and meet UL requirements.
Power cords for Orenco's 4-in. (100-mm) turbine effluent pumps are
Type S00W 600-V motor cable (suitable for Class '1, Division .1 and 2
applications).
Materials of Construction
Discharge:Stainless steel or glass{illed polypropylene
Dischargebearing: Engineeredthermoplastic(PEE}()
Diffusers:Glass{illed PPO
lmpellers:Acetal (20-, 30-gmp), Noryl (50-gpm)
lntake screens:Polypropylene
Suction connection: Stainless steel
Drive shaft:300 series stainless steel
Coupling:Sintered 300 series stainless steel
Shell:300 series stainless steel
Lubricant:Deionized water and propylene glycol
Specifications
Pump Gurves
Pump curves, such as those shown here, can help you determine
the best pump for your system. Pump curves show the relationship
between flow (gpm or Usec) and pressure [DH), providing a graphical
representation of a pump's performance range. Pumps perform best
allhetr nominalflow rate, measured In gpm or Usec.
0.63
FIow in liters per second (Usec)
1.26 1.89 2.52 3.t5 3.79 4.42
Flow in gallons per ninute (gpn)
140
oe r20
Ë'*
!a
ë80
IJ'=
Eoo\È
(!
,E 40
43
eqts¡E
soS
R
È24¡Èei€o
18È
\È
12ì
Ê
20
Nom, flow,
gpm (Usec)
Length
in. (mm)
Weight
lb (ks)
Díscharge lmpellers
in., nominal 1 10 20 30 40 50 60 70
20 (1 ,3) 22.5 (572) 26 (1 1) 1 .25 4
30 (1.9) 21.3 (541) 25 (11) 1.25 J
50 (3.2) 20.3 (516) 27 (12) 2.00 2
Performance
Nom. flow, hp (kW)
gpm (Usec)
Design
flow amps
Rated
cycleVday
Min liquid
level, in. (mm) 2
20 (1.3) 0,5 (0.37) 12.3 300 18 (457)
30 (1.9) 0.5 (0.37) 11.8 300 20 (508)
50 (3.2) 0.5 (0.37) 12j 300 24 (610)
1 Discharge ¡s female NPT threa(led, U.S. nom¡nal s¡ze, to acconmodate 1rencP d¡scharge
hose and valve assenbl¡es. Consult y1ur )renc1 Distr¡butor about f¡ttings to connect d¡scharge
assembl¡es to metric-sized p¡p¡ng.
'z M¡ninum liquid level ¡s fu s¡ngle punps when installed in an 1rencoB¡otubæ ProPakrM Punp
Vault.
.,.a
\
I
PF
t
\
ì
\\
PF
\\
\
I
I
orenco Systems@ lnc, ,814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-¡1449 . www.orenco.com I'ITD-BPP-1
Rev.1,2, @ 08/14
Page 3 of 4
Control Panel (Demand Dose)Gontrol Panel (Timed Dose)
0renco's ProPaK" demand dose control panels are specifically engineered
for the ProPak pump package and are ideal for applications such as
demand dosing from a septic tank into a conventional gravity drainfield.
Materials of Construction
0renco's ProPak timed dose control panels are specifically engineered for
lhe ProPak pump package and are idealfor applications such as timed
dosing from a septic tank into a pressurized drainfield or mound. Analog or
digital limers are available.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel Hinges Stainless steel
Dimensions, in. (mm)Dimensions, in. (mm)
A - Height 11.5 (290)A - Height 11.5 (290)
B - Width 9.5 (240)B - Width e.5 (240)
C - Depth 5.4 (135)C - Depth 5.4 (135)
Specifications Specifications
Panel ratings 120V,314 hp (0,56 kV\4,144, single phase,60 Hz Panelratings 120V,3/4 hp (0.56 k\Â4,14A, single phase,60 Hz
1, Motor-start contactor 16 FLA, t hp (0.75 kW),60 Hz;2.5 million cycles
at FLA (10 m¡ll¡on at 50% of Fl-A)
2. Circuit 120 V, 10 A, 0FF/0N switch, Single pole breakers
3. Toggle switch Single-pole, doublelhrow HOA switch, 20 A
4. Audio alarm 95 dB at 24 in. (600 mm), warble{one sound, UL
Type 4X
5. Audio alarm 120 V automatic reset, DIN rail mount silence
relay
6. Visual alarm 718-in. Q2-mm) diameter red lens, "Pushlo-silence,"
I 20 V LED, UL Type 4X
Control panel, demand-dose
Dual-mode Programmable for timed- 0r demand-dos¡ng
(digital timed-dosing panels only)
1 20 V, repeat cycle from 0.05 seconds to 30
hours. Separate variable controls for OFF and
0N time periods
120-V programmable logic unit with built-in LCD
screen and programming keys. Provides control
funclions and timing for panel operalion
2. Motor-start contactor 16 FLA, t hp (0.75 kW),60 Hz; 2.5 million cycles
at FLA (10 million at 50% of Fl-A)
3. Circuit breakers 1 20 V 10 A, 0FF/0N switch. Single pole 1 20 V
4. Toggle Switch Single-pole, doubleìhrow HOA switch, 20 A
5. Audio alarm 95 dB at 24 in. (600 mm), warble{one sound, UL
Type 4X
6. Visual alarm 7 /9-in. Q7-nn) diameter red lens, "Push{o-silence",
1 20 V LED, UL Type 4X
Control panel, timed-dose (digital timer model shown)
1a. Analog timer
(not shown)
I b, Digital timer
(shown below)
o
@
ffio
ø
@re
t'lfD-BPP-1
Rev.1.2, @ 08/14
Page 4 of 4
orenco Systems@ Inc.,814 Airway Ave., Sutherlin,0R 97479 USA . 800-348-9843 . 541-459-4449 . www.orenco.com
PF Series 4-inch (1 00-mm)
Submersible Etfluent Pumps
fu&çrÍcal gæ$IredOrenco
Applications
Our 4-inch (100-mm) Submersible Effluent Pumps are designed to
transport screened effluent (with lowTSS counts) from septic tanks or
separate dosing tanks. All our pumps are constructed of lightweight,
conosion-resistant stainless steel and engineered plastics; all are field-
serviceable and repairable with common tools; and all 60-Hz PF Series
models are CSA certified to the U.S. and Canadian safety standards for
effluent pumps, meeting UL requirements.
0renco's Effluent Pumps are used in a variety of applications, including
pressurized drainfields, packed bed filters, mounds, aerobic units, effluent
inigation, effluent sewers, wetlands, lagoons, and more. These pumps
are designed to be used with a Biotube@ pump vault or after a secondary
treatment system.
-
Discharge Connection
-
Bypass 0rifice
Franklin
Liquid End
-
Suction Connection
Franklin
Super Stainless
Motor
Featu res/Specif ications
To specify this pump for your installation, require the following:
¡ Minimum Z4-hour run-dry capability with no deterioration in pump life
or performance*
¡ Patented 1Æ-inch (3-mm) bypass orifice to ensure flow recirculation
for motor cooling and to prevent air bind
. Liquid end repair kits available for better longlerm cost of ownership
r lffl-$fifflrv floating impeller design on 10, 15, 20, and 30 gpm
(0.6, 1.0, 1.3, and 1.9 Usec) models; floating stack design on 50 and
75 gpm (3.2 and 4,7 Usec) models
. Franklin Electric Super Stainless motor, rated for continuous use and
frequent cycling
. Type S00W 600-V motor cable
. Five-year warranty on pump or retrofit liquid end from date of manu-
facture against defects in materials or workmanship
. N1t applicable for
'-hp
(3.73 kW) nodels
Standard Models
See specifications chart, pages 2-3, for a list of standard pumps. For
a complete list of available pumps, call 0renco.
Product Gode Diagram
PF t _l
t .+Cord length,
Blank = 1030 =30
ft (m)
(3)
(e)
20 = 20 (6')
50 = 50(1s)
Voltage, nameplate:
1 = 115. 200 = 2002=230t 4 =460
60 Hz
60 Hz
5 = single-phase 50 Hz
Frequency:
1 = single-phase
3 = three-phase
05 -- 1/2hp
10=1hp
20 = 2hp
50 = shp
Horsepower (kVV):
03 = %hp(0.25)
07=%hp(0.s6)
15 = 1-lzz hp (1.1
30 = 3hp(2,24)
1)
(0.37)
(0.75)
(1.50)
(3.73)
Nominal flow, gpm
10 = 10(0,6)
20 = 20 (1.3)
50 = 50 (3.2)
(Usec):
15 = 15(1.0)
30=30
75=75
(1.e)
(4.71
"(D:. @
LH80S80
LFì2053496
Powered by
Franklin Electric Pump, PF Series
- 1á-hp (0,37kW) only
Ì220 volts for 50 Hz pumps
rNotei 2oJoot cords are available only for single-phase pumps through 1 -1á hp
orenco Systems@ lnc. ,814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 o 541-459-¡1449 . www.orenco.com NTD.PU-PF-l
Rev.2,2, @ 09/14
Page 1 of 6
Specifications,60 Hz
o
=oÉt(tø
-9
E
ELEt
.EI' ı6aho\a-v
GE
øo,o
o
Eo
(sÉ
6-v
s
Êtto
=
o
o
!t3Ê
EV
=.E
c
E
'a
Et
o
o_'ä¡gE
ËE
U'=¡-Ë
Ø
0,
q,
ÊL
Ê
ah
ÉL
Etgx.E
=
=-9
.P g.
(l,tsÊl 6
al)Ø
s!
ô.
(t'Et6(l) :!=6Y
Ë-Ë É5E P
Pump Model
PF10051 1 10 (0.6) 0.50 (0.37) 1 1 15 120 12.7 12.7 6 1 1z¿ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF1 0051 2 10 (0.6) 0.50 (0.34 1 230 240 6.3 6.3 6 1 /¡ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF10053200 10(0.6) 0,50(0.34 3 200 208 3.8 3.8 6 11/tin.GFP 23.0(660) 16(406) 26(12) 300
Pt10071245 10 (0,6) 0.75 (0.56) 1 230 240 8.3 8.3 B I /¿ in. GFP 25.9 (658) 17 (4321 30 (14) 300
PF10073200 4,5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 /¿ in. GFP 25.4 (645) 17 (432) 31 (14) 300
PF10101 2 5,6 10 (0.6) 1 .00 (0,75) 1 230 240 9.6 9.6 I 1 /¿ in. GFP 27 .9 (09]' 18 (454 33 (15) 100
PF10103200 16 10 (0.6) 1 .00 (0.75) 3 200 208 5.5 5.5 9 1 1z¿ in. GFP 27.3 (693) 18 (454 37 (n 300
Pt102012qq7,8 10(0.6) 2.00(1.49) 1 230 240 12j 12.1 18 1/¿in.SS 39.5(1003) 22(559) 48Q2) 100
PF1020325,6'B 10(0.6) 2.00(1.49) 3 230 240 7.5 7.6 18 11l¿in.SS 37.9(963) 20(508) 44(20) 300
PF102032005,6,8 10(0.6) 2,00(1.49) 3 200 208 8.7 8.7 18 1%in.SS 37.9(963) 20(508) 44(20) 300
15 (1 .0) 0.33 (0.25) 1 1 15 120 8.7 8.8 3 1 1/¿ in. GFP 19.5 (495) 15 (380) 23 (10) 300PFi 5031 1
PF'l50312
PF20051 1
15 (1 .0) 0.33 (0,25) 1 230 240 4.4 4.5 3 1 1/¿ in. GFP 19.5 15 (380) 23 (10) 300
20 (1 .3) 0.50 (0.34 1 1 15 120 12.3 12.5 4 1 lq in. GtP 22.3 (566) 18 Ø5n 25 (1 1) 300
PF200512 20 (l .3) 0.50 (0,34 1 230 240 6.4 6.5 4 1 lq in. GFP 22.5 (572) 18 Ø5n 26 (2) 300
PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 1/¿ in. GtP 22.3 (566) 18 Ø5n 26 (2) 300
PF201012 4'5 20 (1 .3) 1 .00 (0.75) 1 230 240 10.5 10.5 7 1 /¿ in. GtP 28.4 (t21) 20 (508) 33 (15) 100
PF201 03200 4'5 20 (1 .3) 1 .00 (0.75) 3 200 208 5.8 5.9 7 1 lq in. GtP 27 .8 (06) 20 (508) 33 (1 5) 300
PF201512 4,5 20 (1 ,3) 1 .50 (1 .1 1) 1 230 240 12.4 12.6 9 1 % in. GFP 34.0 (864) 24 (610) 41 (19) 100
PF201 53200 4,5 20 (1 ,3) 1 .50 (1 .11) 3 200 208 7 .1 7 .2 I 1 1/q in. GFP 30.7 (780) 20 (508) 35 (16) 300
30(1.9) 0.50(0.34 1 115 120 11.8 11.8 3 112¿in.GFP 21.3(541) 20(508) 28(13) 300PF30051 1
PF30051 2 30 (1.9) 0.50 (0.34 1 230 240 6.2 6.2 3 1 /¿ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF30053200 30 (1.9) 0.50 (0.34 3 200 208 3.6 3.6 3 1 /¿ in. GFP 21.3 (541) 20 (508) 25 (11) 300
30 (1 .9) 0,75 (0.56) 1 230 240 8.5 8.5 5 1 % in. GFP 24.8 (630) 21 (533) 29 (13) 300Pt300712
PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 lz¿ in. GFP 24.6 1625) 21 (533) 30 (14) 300
PF301 012 4 30 (1 .9) 1 .00 (0,75) 1 230 240 1 0.4 10,4 6 1 /¿ in. GFP 27.0 (686) 22 (559) 32 (15) 100
PF301032004 30(1.9) 1.00(0,75) 3 200 208 5.8 5.8 6 1/+in.GFP 26.4(671) 22(559) 33(15) 300
PF3015124,5 30(1.9) 1.50(1.11) 1 230 240 12.6 12.6 B 1/¿in.GFP 32.8(833) 24(610) 40(18) 100
PF301532004,5 30(1.9) 1.50(1.11) 3 200 208 6.9 6.9 I 1/¿in.GFP 29.8V\n 22þ59) 34(15) 300
PF3015344,5 30(1.9) 1,50(1.11) 3 460 480 2.8 2.8 8 1/¿in.GFP 29.5(685) 22(559) 34(15) 300
PF3020125'6'7 30(1.9) 2.00(1,49) 1 230 240 11.0 11.0 10 1/¿in.SS 35.5(902) 26(660) 44Q0) 100
PF302032005'6 30(1,9) 2.00(1.49) 3 200 208 9.3 9.3 10 1 /¿in.SS 34.0(864) 24(610) 41 (19) 300
PF3030125,6'7,8 30(1.9) 3.00Q.23) 1 230 240 16.8 16.8 14 1/¿in.SS 44.5(1130) 33(838) 54(24) 100
PF303032 5' 6' I 30 (1 .9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 /¿ in. SS 44.3 (1125) 27 (686) 52 Q4) 300
PF30501 2 5' 6' 7, B 30 (1 .9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 /¿ in. SS 66,5 (1 689) 53 (1 346) 82 ßn 1 00
PF3050325,6'8 30CI.g) 5.00(3.73) 3 230 240 16.6 16.6 23 1/¿in.SS 60.8(1544) 48(12191 66(30) 300
PF305032005'6,8 30(1.9) 5.00(3.73) 3 200 208 18.7 18.7 23 1%in.SS 60.8(1544) 48(1219) 66(30) 300
PF50051 1 50 (3.2) 0.50 (0.37) 1 'l 15 120 12.1 12j 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF50051 2 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500532 50 (3.2) 0.50 (0.34 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF50053200 50 (3.2) 0,50 (0.34 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
50 (3.2) 0.50 (0.34 3 460 480 1 .5 1 .5 2 2 in. SS 20.3 (516) 24 (610) 28 (i 3) 300PF500534
PF5007 1 2 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300
PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23J þ8n 26 (660) 32 (15) 300
I'lTD-PU-PF-f
Rev.2.2, @ 09/14
Page 2 of 6
orenco Systems@ lnc. , 814 Airway Ave,, Sutherlin, 0R 9747S USA o 800-348-9843 . 541 -459-4449 . wwlr,,orenco.com
Technieal tlata theçt OrenCO
Specifications, 60 Hz (continued)
ÉlE)
o
=oÊto¡eC'I.v
-=¡ oø6cl\
ıE
øa¡'¡5
o!to
(gÉ
Ðll
.ll
Ët,
6'
=
o
o
E
=â.:¿ E
EV
=.=
EÊ
ÞEtÉo
6)-.äe
sÞËs
o-ø=¡5Ë
6
-fPoct
È
u,ÊL
asx6
=
IorÊ
.s,2ø=(¡)tsE¡6
É)tt
s¡È
€ãsËsz,t
6'E)G
o
E
o
PF500734 50 (3.2) 0.75 (0.56) 3 460 480 1 .8 1 .8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300
Pump Model
PF501 01 2
PF501 034
PF505012 5,6'7'8 50 (3.2) 5.00 (3.73) 1 230 240 262 26.4 13 2 in. SS 65.4 (1661) 55 (1394 64 Qg) 300
50 (3.2) 1 .00 (0.75) 1 230 240 10.1 1 0.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF50103200 50 (3.2) 1 .00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
50 (3.2) 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF50151 24 50 (3.2) 1 .50 (1 .1 1) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100
PF501532004 50(3.2) 1.50(1.11) 3 200 208 7.0 7.0 5 2in.SS 29.3(744) 26(660) 35(16) 300
PF50301 2 4,5' 7' I 50 (3.2) 3.00 (2.23) I 230 240 17 .7 17 .7 I 2 in. SS 43.0 (1 092) 37 (940) 55 (25) 1 00
PF50303200 4'5'8 50 (3.2) 3.00 (2.23) 3 200 208 13.1 .13.1 B 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300
PF503034 4,5'8 50 (3.2) 3.00 (2.23) 3 460 480 5.3 5.3 I 2 in. SS 40,0 (1016) 31 (tïn 55 €5) 300
PF505032 5,6'7'8 50 (3.2) 5.00 (3.73) 3 230 240 1 6.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 Q9\ 300
PF751012 75 Ø.n 1 .00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100
Pt751512 75 ø.n 1 .50 (1 .1 1) 1 230 240 12j 12.3 4 2 in. SS 33.4 (848) 30 V62) 44 (20) 100
Specifications, S0 Hz
Pump Model
PF100752 4,5 10 (0.6) 0.75 (0.56) 1 220 230 6.2 6.2 9 1 /¿ in, GFP 26.8 (658) 17 (432) 30 (14) 300
PF100552 1 0 (0,6) 0.50 (0.34 1 220 230 3.9 4.1 6 1 la in. GFP 23.0 (584) 17 (432) 26 (12) 300
PF101552 r 6 10 (0.6) 1 .50 (1 .1 1) 1 220 230 10.5 11.4 18 1 /¿ in. SS 39.5 (1003) 22 (559) 46 Q|) 300
PF300552 30 (1 .9) 0.50 (0.34 1 220 230 4.1 4.1 4 1 % in. GFP 22.5 (572) 19 (483) 26 (12) 300
PF300752 30 (l .9) 0.75 (0.56) 1 220 230 6.1 6.1 5 1 % in. GFP 24.8 (630) 1 9 (483) 29 (1 3) 300
PF301 052 30 (1 .9) 1 .00 (0.75) 1 220 230 7 .4 7 .4 7 1 1/t in. GFP 28.4 (721) 20 (508) 32 (15) 100
50 (3.2) 0.50 (0.37) 1 220 230 4.0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300
PF3015524'5 30(1.9) 1,50(1.11) 1 220 230 9.3 9.3 8 1lqin.GFP 35.4(899) 24(610) 40(18) 100
PF500552
PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6.3 6.4 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF501 052 50 (3.2) 1 .00 (0.75) 1 220 230 7 .3 7 .4 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF501 552 50(3.2) 1.50(1.11) 1 220 230 9.1 9.1 5 2in.SS 32.5(826) 30(762) 42(19) 100
PF751052 75 (3.2) 1 .00 (0.75) 1 220 230 7 .3 7 .3 4 2 in. SS 30.0 (762) 27 (686) 34 (15) 100
D¡stt¡butor about f¡tt¡ngs to connect hose and valve assenbl¡es to metilc-sÞed pip¡ng.
0renco for morc ¡nfomat¡on.
3 We¡ght includes cafton and 10-ft (3-m) cord.
4 High-pressurc discharge assenbly requircd.
5 Do not ße canJock opti1n (8) on discharge assenbly.
6 Custon d¡scharge assenbly requircd for these punps. Contact 0renco.
7 Capacitor pack (s1ld separately or installed ¡n a custon contrcl panel) requ¡red for this punp. Contact 0renco.
8 Iorque locks are ava¡lable Íor all pumps, and are suppl¡ed with 3-hp and 5-hp punps.
NTD-PU-PT-f
Rev.2.2, @ 09/14
Page 3 of 6
orenco Systems@ lnc, , 814 A¡rway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449. wwworenco.com
Orenco FeÊhfüçat Ð#a $åeef
Materials of Gonstruction
Discharge Glass{illed polypropylene 0r stainless steel
Dischargebearing Engineeredthermoplastic(PEE$
Diffusers GlassJilled PPO (Noryl GFN3)
lmpellers Celcon@ acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3
lntake screen Polypropylene
Suctionconnection Stainlesssteel
Drive shaft 7 116 inch hexagonal stainless steel, 300 series
Coupling Sintered stainless steel, 300 series
Shell Stainless steel, 300 series
Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically
sealed molor housing ensures moisture{ree windings. All thrust absorbed by Kingsbury-type thrust bearing. Baled for continuous duty. Single-
phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp
(1 .1 I kW have built-in thermal overload protect¡on, which trips at 203'221' F (95-1 05' C).
Using a Pump Gurve
A pump curue helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or Usec) and pressure
(total dynamic head, or TDH), providing a graphical representation of a pump's optimal performance range. Pumps peform best at their nominal
flow rate - the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show
optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate
pump specification, use 0renco's PumpSelect'" software.
Pump Gurves, 60 Hz Models
160
0
140
(¡)ql
È 120
R roo
È
3Bos
C!
F60\
:40(È
Ê
20
800
700
t¡).ss 600
=fl soo
È3 ¿oos()
$mo\f zoo(E
Ê
100
0246810121416 36912151821
Flow in gallons per minute (gpm)
0 24
Flow in gallons per minute (gpm)
PFl0 Series,60 Hz,0.5 - 2.0 hp
'., ' i..,.,
)
PF1005 'r¡¡¡i¡l".,il i.';.'..-
-l'
I{\\
PFl005-FC
wlt/t"llow
controller
PF|S Series,60 H2,0.3 hp
",\
NTD-PU-PF-1
Rev.2.2, @ 09/14
Page 4 of 6
Orenco Systems@ lnc, ,814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449 . wwworenco.com
900
800
q)* zoo
È*o
! soo
aJ€t¡ 400
(Es 300È
s 200
-o
100
400
350
q)
q¡
s 300
f zso
È
tEq) 200.È
o
$ rso
\I roo(È
Ê
50
100
90
ae80
s70s5.60È(E
ë50()'È 40t!
È30
E20
10
450
400
a)* sso
È sooa
È 250(Ea
(¡ 200'=
E rso\ÈÈ roo
Ê
50
60 Hz Models (continued)
5101520253035
FIow in gallons per ninute (gpm)
0
10 20 30 40 50 60 70 80 90
Flow in gallons per ninute (gpn)
51015202530354045
FIow in gallons per ninute (gpm)
10 20 30 40 50 60 70 80 90 r00
FIow in gallons per ninute (gpn)
40
0
0
PF30 Series,60 H2,0.5 - 5.0 hp
i:'.:
",.,i,
'.i'.
:
" ì 11::
l
PF20 Series,60 H2,0.5 - 1.5 hp
PF75 Sedes,60 Hz, 1.0 - 1.5 hp
\;
:l
FFEobo PF50 Series,60 H2,0.5 - 5.0 hp
"',.
,^'';
0renco Systems@ lnc. , 814 Airway Ave,, Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449 . www.orenco.com I'ITD-PU.PF-I
Bev.2,2, @ 09/14
Page 5 of 6
Orenco i Tesh*i,çatr Bã*a $fieef
Pump Gurves,50 Hz Models
0.1
FIow in gallons per minute7.9 16 24 32 4{)
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Flow in liters per second (Usec)
Flow in gallons per minute (gpn), noninal63 13 19 25 32
0.4 0.8 1.2 1.6 2.0
Flow in liters per second (Usec)
Flow in gallons per minute (gpn), noninal1019N384857677686
0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8
FIow in liters per second (Usec)
Flow in gallons per minute (gpn), noninal9.5 lt 131.6 3.2 43 6.3 7.9
sza E
è
zoz $
=o
rs7 5.È(!
0)so
131 'È
(E
È
ooF
120
100
eqt
q¡
È
.S 80
F
loo(¡¡€(¡
E¿o\È'
tÈ
Ê
20
525 \
E
459 èÈ
È\
es+ $
gzs Ê
R
zoz Ias
rsz'3
E
rsr È
tÈ
.o66h
180
160
es 140
t¡¡
.S lzo
=at.rooÈ|!
Q¡Ê80
CI'=È
SaoS.È
g40
Ê
20
89-G
7ss
os Ë'qt
ssì
s
¿s S.È
G
ssÊ
o
eoF\zollE
Ê
30
27
(âtzq
P
.È ,'
F"
È
315Ê
'S rz
EÈs
(È
.o6
(!
Èè
Þ\(¡)e
ìo
!Gq¡Ê()
G\È
lÈ
Ê
00
2.400
þpn),
48
nominal56 6Íl
15
98
82
66
49
33
16
45
40
35
30
10
et¡
(¡)
.=
Èı
È(È
t¡)s()
G\È
(E
Ê
3
54 6.01.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
Flow in liters per second (Usec)
0.5
PF10 Series,50 Hz,0.37 - 1.11 kW
PFr005-FC
w/6mmflow
controller
PF30 Series,50 Hz,0.37 - 1.lf kW
". 'i....,.
PF75 Series,50 H2,0.75 kWPt50 Series,50 H¿ 0.37 - l.1l kW
ffi
...'\
:;J;-.\
..>
l ':
NTD-PU-PF-1
Rev.2.2,@ Ogl14
Page 6 of 6
0renco Systems@ lnc. ,814 Airway Ave., Sutherl¡n, 0R 97479 USA . 800-348-9843 . 541-459-4449 . www'orenco.com
This article may describe design critería that was in effect at the time the article was written. FOR CURRENT DESIGN
CNTENA, call Orenco Systems, Inc. at 1-800-348-9843
Orenco Automatic D¡str
Valve Assemblies
nutb g
ã.-,ñtG
For Wastewater Effluent Systems
Introduction
Orenco's automatic distributing valve assemblies, pressurized with small high-head effluent
pumps, are useful for distributing effluent to multiple zones. These zones can be segments
of sand filter manifolds, drainf,relds, or other effluent distribution systems. Distributing
valve assemblies can substantially simplify the design and installation of a distribution sys-
tem and reduce installation costs. This is particularly true where a distributing valve assem-
bly is used instead of multiple pumps and/or electrically operated valves. Additionally, a
reduction in long term operation and maintenance costs is realized due to a reduced size
andlor number of pumps. More even distribution can be achieved on sloping sites by zoning
laterals at equal elevations. This eliminates drainback to lower lines and the unequal distrib-
ution of effluent that occurs at the beginning of a cycle.
Valve Operation
The valve itself has only a few moving parts, requires no electricity, and alternates automati-
cally each cycle. Refer to Figure 1 for the following valve operation description. The flow
of the incoming effluent forces the rubber flap disk O to seat against the valve bottom Ø.
The opening @ in the rubber flap disk aligns with an opening in the valve bottom to allow
flow to only one valve outlet. The stem @ houses a stainless steel spring which pushes the
rubber flap disk away from the valve bottom after the flow of efÍluent stops. The stem acts
as a cam follower and rotates the rubber flap disk as the stem is raised and lowered through
the cam @. The force from the flow of effluent pushes the stem down through the cam and
the stainless steel spring pushes the stem back up through the cam when the flow of effluent
stops. Each linear motion of the stem allows the rubber flap disk to rotate half the distance
necessary to reach the next outlet. When there is no floq the rubber flap disk is in the "up"
position and is not seated against the valve bottom.
Figure l:
6000 Series Valve
Orenco Systems'
I ncorporated
1-800-348-9843
NTP.VA-1
ßev.1.2, @ 11/03
Orenco Syslems@, lnc,
Page 1 ol 6
o
lnlet
-t>
@
o
ø
0utlets
o
,l I
Figure 2:
0renco Distributing Valve Assembly (6000 Series Valve)
The Distributing Valve Assembly
The Orenco Automatic Distributing Valve Assembly combines the distributing valve itself and sever-
al other components to give a complete preassembled unit that is easy to install, monitor, and main-
tain. Figure 2 shows a complete assembly. Because distributing valves with several outlets can be
difficult to line up and glue together in the field, the discharge lines in the assemblies are glued in
place at Orenco. The unions (l) allow removal and maintenance of the valve. The clear PVC pipe
sections (2) give a visual check of which discharge line is being pressurized. The inlet ball valve (3)
allows a quick, simple method to test for proper valve cycling. The ball valve also stops the flow of
effluent in case the pump is activated unexpectedly during maintenance or inspection. Check valves
may be necessary on the discharge lines. Use of check valves is discussed in the valve positioning
section.
Valve Assembly Hydraulics
Liquid flowing through the valve assembly must pass through fairly small openings and make several
changes in direction. Because of this, headlosses through the valve assembly are fairly high. Table I
gives the headloss equations for several different assemblies and Figure 3 shows the graphical repre-
sentations of these equations. Orenco recommends that high-head turbine pumps be used to pressur-
ize the valve assemblies to ensure enough head is available for proper system operation. High-head
turbine pumps are also recommended because the use of a distributing valve usually requires more
frequent pump cycling. The high-head turbine pumps are designed for high cycling systems and will
outlast conventional effluent pumps by a factor of 10 or more in a high cycling mode. Furthermore,
the high-head turbine pump intake is 12 inches or more above the bottom of the pump and tends to
prevent any settled solids from being pumped into the distribution valve and obstructing its opera-
tion. Aminimum flow rate through the distributing valve is required to ensure proper seating of the
rubber flap disk. Minimum flow rates for the various models are given in Table 1.
NTP.VA-1
Bev.1.2, @ 11/03
orenco Syslemso, lnc.
Page 2 of 6
.>
-o
EoaØ
-co,
=oL
-cl-
U)
at)oJ
!(ItoI
Thble 1. Automatic Distributing ValveAssembly Headloss Equations
Model Series Equation Operating Range fgrm)
VMff,A Hl:o.o85xql.45 10-40
v46004 HL:0.085 x ql'58 rc -25
v6400A H¡:0.0045"d+3.5x(1-e-0.06q ß-70
v6600A H¡:0.0049"d+5.5x(1-"-0.19 ß-70
35
30
25
20
15
10
5
0
35 40
Flow (gpm)
Figure 3:
Automatic d¡str¡but¡ng valve assembly headloss curves
The Pumping System
Although the distributing valve was designed for the irrigation industry it has started to gain fairly
wide acceptance in the effluent pumping industry. However, because of the mechanical movements
of the valve, it is necessary to take steps to prevent solids from reaching the distributing valve that
may impede the operation of the valve. Orenco Biotube@ Pump Vaults - when properly sized and
installed - provide the necessary protection to prevent valve malfunction. The Biotube@ pump vault
accepts effluent only from the clear zone between a tank's scum and sludge layers and then filters
this efTluent through a very large surface afea screen cartridge. Without this protection in effluent
systems, the valve has very little chance of reliable long-term operation.
NTP-VA{
Rev. 1.2, @ 11/03
0fênco Systems@, lnc.
Page 3 of 6
051015202530 45 50 55 60 65 70
v66004
,1 f
/
v64004
v46004 -/
v44004l-.¿Jd'4 at/-
-/êrJttJ
/a-
-.1
-.ã
/4 -á
'-t-
-..-¿a f,*-
tt7
-¿ã 4T
Valve Positioning
The physical position of the valve in relation to the pump and the discharge point is very important
for proper valve operation. The most reliable operation occurs when the valve is placed at the high
point in the system and as close to the pump as possible. The transport line between the pump and
valve should be kept full if possible. If the line is empty at the beginning of each cycle, pockets of
air during filling can cause random rotation of the valve. The valve is particularly vulnerable to this
erratic rotation with empty lines that are long and not laid at a constant grade. An ideal valve loca-
tion is shown in Figure 4.
If the final discharge point is more than about 2 feet above the valve and the system does not drain
back into the dosing tank, check valves should be installed on the lines immediately following the
valve and a pressure release hole or line should be installed just prior to the valve. This pressure
release hole or line can go into a return line to the dosing tank or to a "minidrainfield" near the valve.
In order for the valve to rotate reliably, no more than about 2 feet of head should remain against the
valve to allow the rubber flap disk to return to its up position. In many cases, it may take from one
minute to several minutes for the pressure in the valve to be lowered enough for proper rotation to
occur. Special care should be taken when installing systems controlled by programmable timers to
ensure cycling does not occur too rapidly. Figure 5 illustrates a valve assembly using check valves.
Pumping downhill to the valve should be avoided unless the transport line is very short and the ele-
vation between the discharge line out of the tank and the valve is less than about 2 feet. If the valve
is located many feet below the dosing tank, random cycling may occur while the transport line drains
through the valve at the end of the cycle. A pressure sustaining valve located just before the distrib-
uting valve may overcome this problem in some instances.
Valve Assembly
Discharge
Transport Line
Dosing Tank
Figure 4:
ldeal valve location
NTP-V4.1
Rev.1.2, @ 11/03
ofenco Systems@, lnc.
Page 4 of 6
System Startup
Refer to the Hydrotek Valve booklet that is provided with the distributing valve assembly for the
sequencing of the valve outlets. The transport line should always be flushed with clean water before
installing the valve. Any sand, gravel, or other foreign objects that may have been in the pipe during
installation can easily become lodged in the distributing valve, causing malfunction.
With the pump running, alternately close and open the ball valve on the distributing valve assembly
to check proper rotation of the valve. (Note: If check valves are used on the lines after the distribut-
ing valve, the pump may need to be turned on and off to allow the pressure to be released from the
valve.) If visual operation of which zone is operating is not possible, watch the clear pipe on each
line for indication of which zone is operating.
D¡scharge Laterals
Pressure Release
Line if h>2L0"
Valves ¡f h>2L0"
Valve Assembly
Transport Line
Dosing Tank
Figure 5:
Valve assembly below final discharge point
Maintenance
Annually check for proper operation by following procedures listed in the Hydrotek Valve booklet
and system startup procedures listed above.
Troubleshooting
1. PROBLEM: Valve does not change or cycle to next zone oÍ outlet
CAUSE:The stem and disk assembly is not rotating when water flow is turned off and then
back on.
SOLUTION 1: Ensure that there is no debris inside the cam. Clean and carefully reinstall the cam.
SOLUTION 2: If fewer than the maximum number of outlets are being used, check the installation
of the cam. Ensure that the stem and disk assembly is not being held down by an
improperly installed cam. Refer to the cam replacement instructions.
NTP-VA.1
Bev.1.2, @ 1U03
0renco Systems@, lnc.
Page 5 of 6
SOLUTION 3
SOLUTION 4:
SOLUTION 5:
SOLUTION 6
Remove the valve top and check for proper movement of stem and disk assembly.
Check for and remove any debris or foreign objects that may jam or retard the
movement of the disk.
Check for freedom of movement of stem and disk assembly up and down over the
center pin in bottom of valve. Scale deposits may build up on the pin and hold stem
and disk assembly down. Clean pin and again check for freedom of movement.
Be sure that all operating outlets are not capped and that the flow to operating zones
is not restricted in any manner. This would cause pressure to build up in the valve
and lock the stem and disk assembly in the down position.
The backflow of water from uphill lines may be preventing the valve from cycling
properly. This can happen when the valve is placed too far below an elevated line.
If the valve cannot be placed close to the high point of the system, a check valve
should be installed near the valve in the outlet line that runs uphill from the valve
and a drain line installed just prior to the valve to relieve the pressure.
2. PROBLEM: Water comes out of all the valve outlets
CAUSE: Stem and disk assembly not seating properly on valve outlet.
SOLUTION 1: Check for sufficient water flow. A minimum flow rate is required to properly seat
the disk as shown in Table 1.
SOLUTION 2: Remove the valve top and check the inside walls to ensure that nothing is interfering
with the up and down movement of the stem and disk assembly inside the valve.
SOLUTION 3: Make sure that the operating outlets are not capped and that the flow to the operat-
ing zones are not restricted in any manner.
3. PROBLEM: Valve skips outlets or zones
CAUSE:Pumping into an empty transport line - especially downhill - may cause the valve
to skip outlets from pockets of air allowing the rubber flap disk to raise during a
cycle.
SOLUTION l: Keep the transport line full.
SOLUTION 2: If the line must remain empty between cycles, use a larger diameter transport line
laid at a constant grade to prevent air pockets from forming.
CAUSE The stem and disk assembly is being advanced past the desired outlet.
SOLUTION 1: Ensure that the correct cam for the desired number of zones is installed and that the
outlet lines are installed to the correct outlet ports of the valve as indicated by the
zone numbers on the top of the cam.
t{ïP-vA-1
Rev.1.2, @ l1103
ofenco Syslemso, lnc.
Page 6 ol 6
â.-,
ñú
€Distributing Valves Submittal
Data Sheet OrencoSyslemB"
lncorporated
1-800-348-9843
Applications
Automatic Distributing Valve Assemblies are used to pressurize
multiple zone distribution systems including textile filters, sand
filters and drainfields.
coupling
dislributing valve
union
clear pipe
Top View
ball valve
elbow
Side View
elbows
Bottom View
General
0renco's Automatic D¡stributing Valve Assemblies are
mechanically operated and sequentially redirect the
pump's flow to multiple zones or cells in a distribution
field. Valve actuation is accomplished by a combination
of pressure and flow. Automatic Distributing Valve
Assemblies allow the use of smaller horsepower pumps
on large sand filters and drainfields. For example, a large
community drainfield requiring 300 gpm can use a six-line
Valve Assembly to reduce the pump flow rate requirement
to only 50 gpm.
0renco only warrants Automatic Distributing Valves when
used in conjunction with High-Head Effluent Pumps with
Biotube@ Pump Vaults to provide pressure and flow
requirements, and to prevent debris from fouling valve
operation. An inlet ball valve and a section of clear pipe
and union for each outlet are provided for a complete
assembly that is easy to maintain and monitor. ldeal
valve location is at the high point in the system. Refer to
Automatic Distributing Valve Assemblies (NTP-VA-1) for
more information.
Standard Models
v4402A, V4403A, V4404A, V4605A, V4606A, V6402A, V6403A,
v6404A, V6605A, V6606A.
Nomenclature
A-lìn¿i.ut".
assembly
Specifications
Number of active outlets
senes:
44 = 4400series(2-4 outlets)
46 = 4600 series(5-6outlets)
64 : 6400 series(2-4outlets)
66 : 6600 series (5-6 outlets)
Distributing valve
I
Materials of Construction
AllFittings:
Unions:
BallValve:
Clear Pipe:
V4XXX Distri buting Valves:
V6)frX Distributing Valves:
Sch.40 PVC perASTM specification
Sch.80 PVC perASTM specification
Sch.40 PVC perASTM specification
Sch.40 PVC per ASTM specification
High-strength noncorrosive ABS polymer and stainless steel
High-strength noncorrosive ABS polymer; stainless steel, and d¡e cast metal
NSU-SF-VA-1
Bev.3.0 @ 4/03
Page 1 of 2
Distributi ng Valves (continued)
- :lS
à :il¡¡t
SEU'
.EnEt
erE
nloo
EEtúJq,
0
05r015nÃil:1540455055m6570
Flow(gpm)
v66004
v44004l-¿v6400A
v46004l-/-t/
-1 á a '--t*ê'
-.."ë #7r-
Model lnlet Size {in.) Or¡tleb Size (in.} Flow range (gpm} Max Head (ft} Min. Enclosure
V4/f,z{1.25 1.25 t0-40 170 vB121t
v44034 1.25 1.25 10-40 170 V81217
v44MA 1.25 1.25 10-N 170 VB121t
v4605A 1.25 1.25 10-25 170 RR2418
v4606A r.25 1.25 10 - 25 170 RR2418
v6402A 1.5 1.5 15- 100 345 RR2418
v&1034 1.5 1.5 15 - 100 345 RR2418
VEM4A 1.5 1.5 15 - 100 345 RR2418
v66054 1.5 1.5 15 - 100 345 RR2418
v6606A 1.5 1.5 15 - 100 345 RR24r8
itsu-st-vÀ-l
Bev. 3.0, @ 4/03
Page 2 ol 2
Dalet 0712412013Shæt 1 of 'lCh€dedby: DFH]EM bY EMBffiINFILTRATOR.¡ìI$tílsìS ifllìINFILTRATOR SYSTEMS INC.4 Business Park Rd. Old Saybrook, CT 06475(800) 2214436QUICK4 PLUS STANDARDLOW PROFILE CHAMBERPRODUCT SPECIFICATIONS€lê: Nor ro sdEINFILTRATOR SYSTEMS INC.QUICK4 PLUS STANDARDLOW PROFILE CHAMBERPRODUCT SPEGIFIGATION(NOT TO SCALE)TOP VIEWQUICK4 PLUS ALL.IN.ONE END CAP10.4' EFFECTIVE LENGTH-INSPECTION PORT8"3.3" INVER' Tl--,r,,-l13.3" EFFECTIVE LENGTH*QU¡CK4 PLUS END CAPf*- ¿.s" EFFEcrtvE LENGTH.8"3.3'' INVERTl--.tt', -J6"SIDE V¡EWEND VIEW48"(EFFECTIVE LENGTH)B"34"-ALL VIEWS ! INSTALLED LENGTHS
Dare: 05120120'15Sheet I of 1Jfawn by: EMB IS€ls NorrosdElche*ed by: DFH:tfINFILTRATOPINFILTRATOR WATER TECHNOLOGIES4 Business Park Rd. Old Sâybrook, CT 06475(800) 2214436QUICK4 PLUS STANDARD CHAMBERTYPICAL TRENCH DETAILSECTION VIEWIN FILTRATOR WATER TECH NOLOGIESQUICK4 PLUS STANDARD CHAMBERTYPICAL TRENCH DETAILSECTION VIEW(NOT TO SCALE)PRESSURE PIPËIF REQ'D, PER DESIGNNATIVE BACKFILLTOPSOIL6" COVER12" COVER H-112"8'' INVERT34"SPACING PER CODE34"(36" WDE TRENCH)* LENGTH AND NUMBER OF TRENCHES DETERMINED BY DESIGN
Orifice Shields
Orenco I TeetrnicaÍ lÌ&athed
Applications
Orenco@ Orifice Shields are used in a pressurized distribution system
to protect the orifices from backfill debris that might cause orifice
blockage.
'**þ.
¿
â
0rifice shield installed on lateral pipe, standard conliguration
Shield
0rifice
Cutaway view, standard configuration
0rifice
Shield
Cutaway view, cold weather configuration
General
Orenco Orifice Shields snap-fit onto laterals. They may be placed on
top of or beneath a lateral, depending on the location of the orifice.
Orifice shields are covered by method-of-use patent # 5,360,556.
Standard Models
0s075, 0s1 00, 0s1 25, 0s1 50, 0s200
Product Gode Diagram
0s
Lateral pipe size, nominal:
075 = 0.75 in. (20 mm)
0rifice shield
Material of Gonstruction
PVC per ASTM D-1 784
Physical Specifications
Model
Irc 1\.€Â:_
100 = 1 .00 in. (25
125 = 1 .25 in. (32
150 = 1.50 in. (40
200 = 2.00 in, (50
mm)
mm)
mm)
mm)
Shield 0.D.
in. (mm)
Lateral pipe 0.0.
in, (mm)
0s075 3.5 (8e)1.05 Q7)
0s1 00 3.5 (8e)1 .315 (33)
0s1 25 3.5 (8e)1.66 (42)
0s1 50 4.5 (r14)1.90 (48)
0s200 4.5 (114)2.375 (60)
orenco Systems@ lnc, , 814 Airway Ave., Sutherlin, 0R 97479 USA . 800-348-9843 . 541-459-4449 . wwworenco,com NTD-SF-0S-1
Rev.1.1, @ 09/14
Page 1 of 1
ftem#
SEK.Orenco@ Flushing Assemblies
Flushinq Assemblies
Orenco@ flushing assemblies provide easy
access for lateral maintenance. Flushing
assembly kits include a PVC sweep with ball
valve and a polyethylene valve box enclosure.
Orenco@ flushing assemblies are avaÍlable in the
following sizes:. !" diameter. L25" diametero 1.5" diameter. 2" diameter
Valve Boxes
Orenco@ valve boxes are used to provide access
to flushing assemblies. Constructed of
polyethylene.
Valve Box, 7-in. diameter round enclosure
Note: Kits include VB7 valve box enclosure.
t'.-->*o
%'%ffi
îfRTIEY
PREtffST,tnc.
Water &
Wastewater. Systems. Products. Service
(7ts) sss-G7l4 fi:j:ffintY Road 317
Fax: (719) 395-3727 Buena Vista' co 81211
Websiter http ://valleyprecast.com/
Email : frontdesk@valleyprecast.com