INVOLVÊÐ PARTIES
Unit AD - MAX¡MUM SIZE OF 1,OOO SQUARE FEET
tV¿ Fep'*u /ta;¡tQ tv r<r+áa ,Tlie
propertyowner: Sperry Family Trust (Brian Sperry) phone:303 514-1 056
Mailing Address:2877 Loma Place, Boulder, CO 80301
Email Address:brian lsperry@g mai l. com
Contractor:Phone: (_)
Mailing Address:
Email Address:
DemolitionCommercial/Multi-Family
Manufactured Home (Single or Multi-Level)
I
ReroofResidential (SF, Duplex or Townhome)
Mailing Address:
Architect:Phone:
Email Address
Mailing Address:
Email Address:
Manufactured Home rnsta¡"r. Overholt Sheds Phone (970 t874.7070
Mailing Address:1796 Hwy 50 Delta Co. 81416
Email Address:i nfo@overholtsheds. com
PROJECT DETAITS
Describe Work:Overholt will deliver via truck from Delta Colorado a 16x32 feet "Elite Series Workshop (metal)" shed (documents
attached) and place on a gravel pad. No concrete or sunk-into-ground pilings used. No electrical, water, toilets or heat installed.
Job Address:3 miles west of 320 Rd between Beaver Creek and Porcupine Creek,
Assessor's Parcel Number
Sub.Lot Block
Owner's Valuation of Work: S $20,000 Property Size (Sq. Ft. or Acres)
Sq. Ft. of Building . 512 Height:10 ft # of Floors 1
Class of Work:EW Addition
Engineer: Phone: (-)-
Garage:Attached
Remodel/Alteration
Detached
. 10 acres
Septic:
Type of Heat:
. PROJECT DETAITS CONTINUED
Community
Natural Gas Propane E lectric Other
Driveway
Permit:
Exempt
NOTICE
Authoritv. ThisapplicationforaBuildingPermitmustbesignedbytheOwneroftheproperty,describedabove,
or an authorized agent. lf the signature below is not that of the Owner, a separate letter of authority, signed by
the Owner, must be provided with this Application.
LeÊal Access. ABuildingPermitcannotbeissuedwithoutproofof legalandadequateaccesstothepropertyfor
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1-) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICAT¡ON
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other
data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming
completeness of the submittals and approval of this Application, a Building Permit will be issued granting
permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by
the Building Division. ln consideration of the issuance of the Building Permit, I agree that land my agents will
comply with provisions of any federal, state or local law regulating the work and the Garfield County Building
Code, OWTS regulations and applicable land use regulations (County Regulation(s)). lacknowledge that the
Building Permit may be suspended or revoked, upon noticefrom the County, if the location, constructlon or use
of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) orany
other applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1)
requiring the correction of errors in the submittals, if any, discovered after issuance; or (21 stopping
construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other
applicable law. Review of this Application, including submittals, and inspections of the work by the Building
Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions or
discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws
and County Regulations rest with me and my authorized agents, including without limitation my architect
and/ or builder
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided the required on and accurate to the best of my knowledge
Brian L Sperry 4-15-21
Property Owner Print and Sign Date
Permit #:
OFFICIAL USE ONIY
'0""^' Y))iJLø't¿ø sfuzae 4d 4r. on /âr4 a ur'lØ //s<
Manu. }fome Fee:
N/^
Misc. Fees:A//r+Plan Check Fee
6H5. il Pelmit Fee:#22,ÆAdiusted Valuation: -ötz- 29gØ
OWTS No:
-x/,r
Fees Paid:
{ tq s.!Balance Due:
#2re,26 BrRE-68?3
BP No:otal Fóes:.fiabg,3bT
Zoning:
BVt?.AL
OCC Group:/K2 Const. rrrÌKUsetbackö!
b-Û-BUILDING / PTANNING DIVISION :
Signed Approval Date
Gurfield County
BUILDING DEPARWENT
708 Eighth Street, Suite 407, Glenwood Springs, CO 87607
Tel: (970) 945-8272
PLAN RE VI EWC HECKLIST
6her-¿l-z/-¿gF3Permit No:
Building lssues Pl a n n ing lToning lssues
Nft Engineered Foundation
Driveway Permit
Surveyed Site Plan
Septic Permit and Setbacks
Grade/ TopograPhY 30%
Attach Residential Plan Review List
Subdivision Plat Notes
Fire Department Review
Valuation Determination/ Fees
Red Line Plans/ StamPs/ Sticker
Attach Conditions
Applicat¡on Signed
Plan Reviewer to Sign APPlication
Parcel/schedule No'
40# Snowload Letter - Manu. Homes
Soils Report
Property Line Setbacks
30 ft. Stream Setbacks
Flood Plain
Building Height
Zoning Sign-Off
Road lmpact Fees
Grade/ Topography 40%
Planning lssues
Subdivision Plat
(r/
(/
,./
NA
(/
naê/et*b¿tn/S
Descri otion & Summa
,J
TtZ sf x ô 24 -- ÇtZ, Zg8, 00
ú¿n¿ø/oa/ n
2/or/2¿//SÁd L'/È4:
Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.
Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Official that additional information is necessary to review the application
andior plans for compliance, the application may be placed on hold untilthe required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
o
a
Vtrz
Property Owner Print and Date
Eprn, / V eER/
Gørfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(9701s45-82t2
www.sarfiel ntv.com
SINGLE FAM¡LY OR DUPLEX BUILDING PERMIT APPLICATION CIIECKLIST
ln order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application. Parcel number obtained from the County Assessor's Office.. Job address (assigned physical address). Legal Description: block, lot, tract, subdivision, filing, or section, township and range.. Owner's name, mailing address, phone, fax or cell.. Contractor's name, mailing address, phone, fax, or cell.¡ Architect and/or Engineer's name, mailing address, phone, fax or cell.o Building size, height, number of stories and lot size.. Type of Construction (Residential).. Class of Work (New, Remodel/ Alteration, Addition, Repair, Move/ Relocation).. Detailed description of work.. Type bf heating (natural gas, propane, electric, other).. Sewer system (Community or OWTS), also see other items below.. Garage (Attached or Detached).. Driveway permit (please see other items below).o Valuation (labor and materials), see attached worksheet.
OTHER ITEMS:o WILDFIRE Mlïl - All Garfield County property owners are recommended to employ
wildfire mitigation strategies in the development and construction of all buildings throughout the
County. Please refer to the following publication: "FireWise Construction: Site Desiqn & Buildinq
Materials" which is available from the Colorado State Forest Service for specific wildfire mitigation
strategies applicable to your project.
. lf you anticipate obtaining a water-tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. Required to submit building permit application.. OWTS requires a septic permit application to be submitted with the building permit application.o A separate electrical permit must be obtained from the State of Colorado Electrical Board.
o At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Department can be reached a|970-625-8601.. lf you anticipate excavating or grading prior to issuance of a building permit, you will be required
to obtain a separate grading permit.
. lf you belong to a Homeowners Association (HOA) it is your responsibility to obtain written
approval, if required.. Provide copies of any Resolutions and/or Land Use Permits associated with this property.
. Additional Dwelling Units may require Administrative Review.. A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups,
unless the homeowner is performing the work.
BU|LDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete,
identical, legible and to scale. All plans will be checked at the counter for completeness. lf any of the
required information is missing, the building permit application cannot be accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
Property address/legal description.
North Arrow and Scale on each page,
Show all property lines, building envelopes, flood plain and easements.
Provide setback distances from boundaries, buildings, septic, well and waterways.
Location and direction of the county or private road and driveway accessing the property.
Proposed and existing structures. lnclude sheds, barns, decks, patios, and any other buildings.
Existing and proposed grade, positive drainage around structure (to be contained on site).
Streams, rivers, creeks, springs, ponds and ditches.
Existing and proposed wells, septic tanks, leach fields and other systems (if applicable).
Retaining walls (engineer stamped detail required for walls over 4 ft., measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
. Minimum of four (4) elevations (N,S,E,W). lndicate height of building measured from existing
grade to the midpoint between the ridge and eave of a gable or shed roof or to the top of a flat
roof.o Floor plans for each level, including dimensions and scale noted.. Clearly label each room or space (bedroom, bath, kitchen, closet, etc).o Show the location of the mechanical equipment.. Building cross sections with construction details.¡ Window sizes, types and operation noted on the floor plans or elevations.. Specify roof slope/pitch, roof covering and siding materials.o Stair and guard details specifying rise, run, height and spacing.. Attic, roof and crawlspace ventilation details. lndicate size and location of ventilation openings.o Minimum insulation shown for walls, floors, roofs/ceilings, slabs, basements and crawlspaces.. Provide stove and fireplace make, model, EPA or Colorado Phase ll Certification. Masonry
fireplaces shall be designed to the lnternational Residential Code (lRC) requirements.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
r SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.. Foundation plan showing complete footing and foundation dimensions.. Footing and foundation details specifying reinforcement and referenced on plans.