HomeMy WebLinkAboutOWTS DesignI29 CAINS LANE C¡ReoNnel-r, CO A1623 970.309.5259 CARLA. OSTBERG@GMAIL.COM stt¡"l'r( : <'( Dl;slt'f .'l'lls(i May 25,2021 Project No. C1596 Sherman Muller shermanlt(@me.com clo Martin Mata matadesiqn(Omac.com Subsurface lnvestigation and Onsite Wastewater Treatment System Design 4 Bedroom Residence TBD Clipper Place Garfield County, Colorado Sherman, CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) d'esign for the subject residence. The 32.376-acre propefi is located outside of Carbondale, in an area where OWTSs are necessary. Legat Description: Section: 29 Township: 7 Range:87 Subdivision: STIRLING RANCH PUD Lot: 24 32.377 ACRES Parcel lD: 2391291 05024 SITE GONDIT¡ONS The property is currently undeveloped. A 4-bedroom residence is proposed. The residence will be served potable water from a community water system. No OWTS component will come within 25-feet of the water line as it enters the property from the east. The proposed soiltreatment area (STA) location has an approximate five to ten percent slope to the north. The proposed area is located north of the residence. There should be no traffic or staging of material over the future STA site to avoid compaction of soils prior to construction of the STA. SUBSURFACE The subsurface was investigated on March 16,2021 by digging two soil profile test pit excavations ([est Pits). A visual and tactile soi analysis was completed by Carla Ostberg at the time of excavation.l The materials encountered in Test Pit#1 consisted of dark brown topsoil to 1.5-feet, underlain by medium brown to clay loam to a maximum depth explored of 6.5-feet. No bedrock or groundwater was encountered. r Carla Ostberg holds a Certificate of Attendance and Examination from the CPOWVisual and Tactile Evaluation of Soils Training. Page2 The materials encountered ¡n Test Pit #2 consisted of dark brown topsoil to 1 .5-feet, underlain by medium brown to clay loam to 4.5-feet, underlain by dense, tan calcareous clay matrix to a maximum depth explored of 7.O-feet. No bedrock orgroundwaterwas encountered. A sample of the soils was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was moderate. The soilformed a ball and a ribbon 1 to 2-inches in length before breaking. Soil structure shape was blocky and consistence was friable to firm. Soil texture was both gritty and smooth. STA sízing is based on SoilType 3, Clay Loam with moderate structure grade. A long term acceptance rate (LTAR) of 0.35 gallons per square foot will be used to design the OWTS. Test Pit #1 { å 1.I: Backfill Page 3 i;;"''d,; ' .i.,s rii.li r t¡.îÉÈ$'{S4i¡i ;1¡f:1j.,;¿r1 jil::+t.rjiHÈ\¡i,iÀ;r;. i . :ånaü*1r.._,.,,..,, Jt*ri*;¡,., ':;;.-,,r'-.' View of Test Pit #1 Ë o Test Pit #2 Sieved sample Ribbon 1-2 inches in length Page 4 DESIGN SPECIFICATIONS Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4ü' Bedroom) = 525 GPD LTAR = 0.35 GPD/SF 525 GPD / 0.35 GPDiSF x 0.8 (pressure dosed trenches) x 0.7 (chambers¡ = 840 SF The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used. For the purposes of this OWTS design, Benchmark Elevation at lower-level finished floor 7104' has been established as 100'. The sewer line will likely exit the crawl space at approximately 98' (7102'). CBO lnc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. *Elevations are based upon standard installation due to site conditions. installation practices. Component elevations may change during The sewer line exiting the residence must have a double-sweep clean out and a minimum 2o/o gradeto the septic tank. ln order to achieve gravity flow to the septic tank, it must be installed near the existing fence line. An additional clean out must be installed in the sewer line because of the length of the run. The system installation will include a 15OO-gallon, two-compartment poly lnfiltrator@ septic tank with an Orenco Biotube Effluent filter on the outlet tee followed by a S0O-gallon poly lnfiltrator@ pump chamber with an Orenco@ Biotube Pump Vault and an Orenco@ PF3005 pump. The floats should be set to dose approximately 70 gallons each pump cycle, allowing approximately 6 gallons of drain back after each pump cycle. A pump curve is enclosed. The control panel for the pump must be located within line of sight of the septic tank. We recommend Valley Precast out of Buena Vista be contracted for start-up of the pumping system. Table A 1.5-inch diameter Schedule 40 pump line must be installed from the pump to an Orenco@ automatic distributing valve (ADV), model 6605. This pump line must have a minimum 1o/o grade for proper drain back into the tank afrer each pump cycle. The ADV must be placed at a high point in the system and be placed in an insulated riser with access from grade. Screened rock must be placed below the ADV to support the ADV and to assure the clear pipes existing the ADV remain visible for future inspection and maintenance. Minimum ElevationOWTS Gomoonent Approx. horizontaldistance 94'l min. 2o/ofall / min. 23.5'fall to seotic tank Primary Tank lnlet lnvert Automatic Distributing Valve Approx. horizontal distance 58' / min. 1o/o rise I min.7.25" rise lnfiltrative Surface (to furthest trench)Approx. horizontaldistance 45' Imin.lo/otall / min. 5.625" fall to furthest trench Min. 50 gal. (11 gal x 4) + 6 gal drain back Dose Range Max = 137.25 gal. (525 GPD x 25o/o + 6 gal drain back) 6 gallons drain back (58' / 1.5' diameter pump line) Dose Setting 70 gallons/dose 5.5" on/off float separationFloat Separatíon 500 gallon single-compartment lnfiltrator@ poly pump tank 15.7 gallons per minute (GPM)19.2 feet total dynamic head (TDH) Pump Criteria Page 5 Effluent will be pressure dosed through 1.5-inch diameter pipes to five trenches, each w¡th 14 'Quick 4' Standard Plus lnfiltrator@ chambers, for a total of 70 chambers and 840 square feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each trench. Effluent will be pressure dosed to 1.5-inch diameter laterals, which must be hung with zip ties from the underside of the chambers. Laterals will have 5/32-inch diameter orifices facing up, with the exception of the first and last holes facing down for drainage. Orenco@ Orifice Shields may be placed under each downward-facing orifice. The orifices must be placed 2.5-feet on center. Each lateral must end in a 90 degree ellfacing up with a ball valve for flushing. Valves may be placed in a valve box, accessible from grade, for access. lnspection ports must be placed at the beginning and end of each trench. Ports may be cut to grade and covered wíth a valve box for access. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. GBO lnc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. Construction must be according to Garfield County On-Site WastewaterTreatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. INSTALLATION CONTRACTOR CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our offce in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communícation between the installer and this office is expected throughout the installation. COMPONENT MANUFACTURER MODEL NO GOMMENTS Septic Tank lnfiltrator@ Item # lM-1530-2CP 1SO0-gallon,2- :ompartment poly septic lank Effluent Filter Orenco@ 4-inch diameter, full size filter and housinq Pump Tank lnfiltrator@ Item # lM-540-HH 500-gallon, single compartment poly pump chamber Pump Orenco@ PF30051 1 Y2HP 120 Volt Biotube ProPak Pump Packaqe Orenco@ BPP3ODD /ault, Filter, Control Panel 'demand dose) Tank Risers and Lids Orenco@ Double-walled PVC Risers and Lids (24" diameter) ADV Orenco(Ð v66054 1.5" lnlet and Outlets ADV Riser and Lld Orenco@ Double-walled PVC Risers and Lids (30" díameter) Or¡t¡ce Shields Orenco(Ð os150 1.5 inch diameter (10 total) Flushing Assembly Orenco@ 1.5" cliameter (2) 45" or 90" long sweep only (5 total) Chambers lnfiltrator@ standard Plus 70'Quick 4' Standard Plus Chambers Page 6 INSTALLATION OBSERVATIONS CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before backfìll, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing síphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours in advance to observe the installation. ln an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if appl¡cable), septic tank location, STA location, and measurements from building corners or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular inigation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining seruice contracts for manufactured units, altemating STAs, and any other components needing maintenance, Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the O\ /TS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. PageT Excavation equipment must not drive in excavation of the STA due to the potential to compact soil Extensions should be placed on all septic tank components to allow access to them from existing grade Backfill over the STA must be uniform and granular wíth no material greater than minus 3-inch. LIMITS: The design is based on information submitted. lf soil conditions encountered are different from conditions described in report, CBO lnc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specifled in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Síncerely, CBO lnc Reviewed By: (p',,, (* ts+ bu 'g Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE " 6-2-2021 t Í h ai¡ o cñ.38823 Pump Selection for a Pressurized System - single Family Residence Project MULLER RESIDENCE / LOT 24 STIRLING RANCH Paramètêrs Discharge Assembly Size TÊnsporl Length Before Valvé Transport Pìpe Class Transport L¡ne Size Distribuling Vatue Model Transport Length Aller Vâlve ïEnsport P¡pe Class TEnsport P¡pe Size Ms Ëlewt¡ø Lift Man¡fold Lôngth Manifold P¡pe Class ft¡lanifold P¡pe Size Number ofLâtôrals per Coll Lateral Length Lateral P¡pe Class Lateral Pipe Size Orilice gize Oriñco Spacing Res¡dual Head F¡ôw Mêlet 'Add-on' Friction Losses 300 Câlculat¡ons 1.25 58 40 1.50 6605 45 40 1.50 5 0 40 1.50 5 56 40 1.50 5t32 2.5 5 None 0 ¡nchs fæt inches fæt ¡nches ¡nches feet inchos inches feEl feet fæt feet ¡nches fed 150 t Attt. :Eôt- 't3a 'oI It E Ê5c¡ ã o [4inimum Flow Râlê per Orifice Number ol Orillces per Zone Total Flow Rale per Zone Number ofLatsals per Zone ô¿ Fl@ Differont¡al lsulast or¡ficG TÊn8port Velocity Before Valve TËnsport Veloc¡ty Afrer Valve 0.68 15.7 1 2.5 2.5 gpm gpm i/i, fps fps Loss through D¡scharge Loss ¡n Transport Beforê Valve Los through Valve Loss ¡n Tr¿nsport afierValvo Loss ¡n Mânifold Loss in Lalerals Loss thrcugh Flwmeter Add-on' Fricl¡on Losses Pipe Volumes 1.7 0.9 5.6 o.7 0.0 0.0 0.0 fæt feet fæt fGôt feel fegl feet feet 100 50 PumpDetâ Vol ofTransport Ljne Before Valve Vol ofTranspoú UneAner Vâlve Volof Mânifold Vol ofLâterals psrZone Total Vol Before Valve lotal Vol Afrer Valve M¡nimum Pump RequiremenG 6.1 4.8 0.0 5.9 6.1 10.7 gals gals gals gals gals gals 0 5 10 40 Design F¡ow Rate Total Dynam¡c Head 15.7 19.2 gpm 15 20 25 Net Discharge (gpm) 30 35 Pump curye: Pump Opt¡ma¡8ango: operatìËiPo¡nt: oesiftoint: fæt Legend PF30O5 H¡gh Head Effuent Puñp 30 GPM, 1/2HP 1 1 5123(N 1ø 60H2, 200V 3ø 60H¡ PF3O07 H¡gh Head Efrlueoi Pump 30 GPM,3/4HP 230V 1 ø 60H2, 200/,160V 3ø 60Hz PF3010 H¡gh Head Effuent Pump 30 GPM, IHP 230V 1ø 6OHZ,2O01460V 3ø 60Hz PF3015 H¡gh Hsd Efiuent Pump 30 GPM, 1.I/2HP n(N 1ø 60Hz,2oOl230l460V 3ø 60Hz -T ta.0NIXXX¡.. IIIt-SCALE: I = 50'=0"TPÀI,,1I-,tITP+óÈ''tîðÞBARNRESIDENCE-t--- }-. 5f+,//i PROPERWì,/./.-PLACÉ,/ah_,/.., ¿'THE LOCAÎION OF PROPOSEOSHOWN ARE NOT THE RESULT OF AsroPROPERTY SURVFT/. THÉ LOCATIONS ARE ^PPROXIMATE, lT lS IHE HOMEOWNERS DUTYTO ENSURE ALL CONSTRUCTION AND IMPROVEMEÑT LOCATIONS ARE ACCIJRATÊ.PROPËRTY LINES AND SETBACK DISTANCES SHOULD gE CONFIRMED PRIOR TO/EXCAVATION. SCA¡-ED FOR PRINTING ON 11'17'PAPERI,' ,,/,'l'/DRAWINGS MUST BE USED INCONJUNCTION WTH DESIGNLETTER DATED 05/252021ORIVEWAYlhìw1 .0Shs€t I 0F 4Muller ResidenceTBD Clipper PlaceGârñeld County, ColoradoProþctNumb€n C1596o5nsno21by: CBOby: RBby: DDCBO lnc.ili¡ FourWhæl ùiye RoadCaÈondåle, Colorado 81 623Phone 970,309.5259carla.ostb€rg@gma¡|.æm I.5- DIA SCH4O PUMP LINE.(MIN 1% DRAIN BACKTO TANK)SEWER PIPES CAN BE RUN IN SAME TRENCH IFDESIRED TO MINIMIZEO SITE DISTURBANCE.5 TRENCHES EACH WITH 14 'QUICK 4'CHAMBERS = 70 CHAMBERS =MO SF1.5' DIA SCH.4O PVC SUSPENDED LATERALS WTH 5/3? DIA ORIFICES2.5' O.C. FACING UP. FIRST AND LAST ORIFICES FACING DOWN FORDRAINAGE COVERED WITH ORIFICE SHIELDS1sOO-GALLON 2-COMPARTMENT POLY SEPTG TANKFOLLOWED BY A sOO€ALLON SINGLE-COMPARTMENTPUMP CHAMBER. RISERS AND LIDS TO GRADEXX:¡Nt'l3cN!l eNuslr¡- 4' DIA SOR.35 INSPECTION PORT ATBEGINNING AND END OF EACH TRENCH7ts7\dlå/+TP2\¡oomonnl clenN our oN 4" DIA sDR-35SEWER LINE\4' DIA SDR.35 SEWER PIPE WTH CLEANOUTMIN 2% FALL TO TANKFLUSHING VALVE AT END OF EACH LATERAL7t1.5' DIA SCH.4O DISTRBUTION LINES 10 ÊACH TRENCHFUTURËN_' _- '. ADV MODEL 6605AT HIGH POINTWTH ACCESS AT GRADE7103SCALE:1"= 2O{)'*o'*;1"- -----'ì7o110104 AFR.^/ \/ñPROPOSED OWTSæ04prArûs&w2.0She6t 2 0F 4Dalei 0il292021Des¡gned by: CBORevi€wed by: RBDrawnby: DDMuller ResidenceTBD Clippsr PlacsGaffi èld County, ColoradoProjoct Number: C1596CBO lnc.33 FourWhælDrive RoadCarbondåle, Colorado 81623Phons 970.309.5259€rla,o€tb€rg@gmail "com INFILÍRATORENO PLATEGMVÊLLESS'QUICX4'CHAI¡SER (a'r 3)1,5' DIA SCH¡O SEWERLINE 10 ÊACH TRÊNCHL5. DtA 8CH.40EFFLUENT PIPE FROMMffiERSLIP-ONACCESS ATIN IOP PORÌINSPECTIONDO NOT GLUEGRADÉINSULATEDPUCED4'TRACERWREFINISHED GRADEOF C'IIÁ¡IIBÊR ÉNO PLAIESsolL2DISÌR|AUT|ON LINES4'TO OIHER TRENCHES(5 TOTAL)SÉYVER UNËDIA SDR¡s INSPECTIONEXCAVAÎONPORI AT BEGINNII.IG ANDEND OF EACH TRÊNCHl¡UtCK4,SUSPEND LATERAf,SCHAI¡EER (4 r g)END EACH I.Â'TËRAL IN A 90' LONGSWEEPING ELL FACING UP WlH A BAIIVÀVE IN A VALVE BOX ACCËSSIBLÊ A1GRADEI .I DIA SC}I.4O PVC STJSPENOED NÌERALwfrH c32" DlA oRrFlcÉs AT 2.$ o,c. FACTNGUP. FIRST AND TÄSI ORIFICËS FACE DOVYNWIH AN ORIFICE SHIELO FOR DMINAGEZIP.Í¡ES TO UNDERSIDEOF CHAMBERS/I CHAMBER fRENC+t PLAN\!r____ru.Fræ@,ç!rycroN ,o/^"rorr.ru""^.:êi,Eåå?ixi8-/ã CaEÂ,NOUT DEÍAIL\gr-rrüESMAI VIW COVERBOX OR RRETNNVALVE gOX Al GME30" DI¡'METER PVC1 O' DIA VALVE BOXWlH SECURED LID1.5" Br'C SLIP X MALEPIPE THREADADAPTERWCAF1.5'DIA BALLVALVERISERCAP OR THREÆ)EDCLilOUTASSffiLYr.5'DrASCH40 Pl/CLONG SV\TËEP gO" ELBOWÊASE TO SUPPOfITBüF^/C PIPE CUTTODISTRJBUIINGVALVE ASSEMBLYÊND CAPFROMUSE HûE SW TOCUT ffRU rcP OFPUMPING.5'DTASCH-1015" ÐtA Sot-t4o F{/CSUSPENDED LAIERAI-ENDPl/C INLÊÎ ANDOU'TLETS/;\INSPEC1ION PORI IN OIAMSER\1/-ffi/ã\ AUTOMATC DISTRIBUÎNG\gr'-"'...............'-MVALVÊ DETAIL/: FLUSHING VAL\Ê DEIAIL\gr-¡tTlæw3.0Sheet 3 0F 4Muller ResidenceTBO Cltpp€¡ Plac€Garfield County, ColoradoProject Numb€n C1596luat,: o5t2sfal21tes¡gneo ¡y: ceo¡Rêvlevtred by: RBlDrawn by: DDCBO lnc,33 F@r Whod Dri\€ RoadCe¡bondale, Colorado 81623Phons 970.309.5259carla.oslberg@gmâil,com DESIGN4€EDROOT RESIDENCÊ75 GPD x 2 PERSOilSBEDROOM x 3 BEDROOMS + 75 GPD (4TH BEDROOM)WASTEWATER FLOW = 525 GPDTANKMIN. I25O GALLONS + CAPACITY FOR PUMPING SYSTEMUSE 1sOO.GALLON, TWO{OMPARTMENT POLY SEPNC TANK + S@ G¡LLONPOLY PUMP CFIAMBÊROWTS COMPONENTS ANDPHYSICAL FEATURESMINIMUM REQUIREDSÊlBACKAPPROXMATE PROPOSEDSE'ÍBÀCKHOUSÊ TO SEPTTC fArü(&tSEPTIC TANK TO WELL50N/ASEPTIC TANK TO WATER COURSÉ50,N/ASTA TO HOUSE2g44'STATO WErl-100'l,UASTA TO WATER COURSEwASOIL'ÍREATMENT AREA (STA):LONG TERM ACCEPTANCE RATE (LTAR) = 0.35 GAU SFCALCULATED STA = Q/LTAR = 525 / 0.35 = 1500 SFPRESSURE DOSÉD TRENCHES = 1500 SF X 0.8 = 1200 SFCHAMBERS = 1200 SF X0.7 = 840 SF5 TRENCHÊS, EACH WTTH 14 QUICK 4 INFIL'IRATOR CHAMAÊRSTOTAL 70 CHAMBËRS,840 SF INFILTRATIVEAREASOIL PROFILE TEST PIT NO. ISOIL PROFILÉ TEST PIT NO, 20I234567I910DARK BROW! IOPSOIL24' TOPSOIL AND ROOT ZONE DEPTHMÊDIUM BROWN CI..AY LOAMMEDIUM BROWN CLAY LOAMFINISHED GF¿ADETAN CALCAREOI'IS CLAY MATR¡XLÊGENDf! ¡op8o¡lF:T€lcâmGciåy maüixf,?l aavmm4' DIA SDR.35 SEWER LINE(MrN 2% SLOPE TO TANK)NO GROUNOWATË.R OR BEDROCK ENCOUNTÊRËODURING EXCAVATIONSCREENEDOR SAND FORBEDDING3r MtN.rMIN,¡.1SOII.S LOG\rr-----ñæA'IRENCH DETAIL\lr--GræIBACKFILLw4.0Sheet 4 0F 4Date: 0512512021Des¡gned bli: C8OReviewed by: RBDrawn blr DDMuller ResidenceïBD Ctipper PlaceGarfi eld Coun9, ColoradoProjedNumb€r: C1596CBO lnc,33 Ferwhæl ùive RædCarbondale, Colorâdo 81623Phonè 970.309.5259carla.cçtb€¡g@gmail.com 5t29t2021 qPubl¡c.net - Garfield County, CO - Property Record Card: R008799 fÐ qPublic.net'" Garfr eld County, CO Summary Account Parcel Property Addr¿ss Legal Description Acres Land SqFt TaxArea Mill Levy Subdivision @,-&p Owner MULLER,SHERMAN & JAME5, JANICE 2SOOVERLOOK ROAD CARBONDALE CO 81ó23 Land UnitType VACANT RES LOTS - 0100 (VACANT LAND) Square Feet 0 Actual Values Assessed Year Land Actual lmprovement Actual Totâl Actual AssessedValues Assessed Year Land Assessed lmprovement Assessed Total Assessed Tax History Tax Year Taxes Bi¡led R008799 239r29t05024 OCLIPPER PL, CARBONDALE, CO 81ó23 Section: 29Township:7 Range: 87 Subdivision: STIRLING RANCH PUD Lot:24 32.377ACRES 32.376 0 7I 75.5380 STIRLING RANCH PUD 2020 94,928.84 202L $2s0,000.00 $o.oo $250,000.00 2021 $72,s00.00 $o.oo $72,500.00 2079 $4,972.64 2020 $225,000.00 $o.oo $225,000.00 2020 $ó5,250.00 $o.00 $ó5,250.00 2018 $4,L67.O4 20t9 $225,000.00 $o.oo $225,000.00 20t9 $ó5,250.00 $o.oo $ó5,250.00 2017 $3,983.1ó Click here to viewthe tax lnformation for this oarcel on the Garñeld Countv Ïreasurer's webs¡te. Transfers 77/2I/2007 WARRANryDEED 7t3!/2OO6 QUITCLAIMDEED Sale Date 9/24/2020 6/7/20t9 Deed Type WARRANTY DEED AGREEMENT Rêception Number 942657. 942L75 Book - Page 1835- 01ó0 1354-672 1354-662 7322-402 L322-407 L269-478 7769-631 679-804 ó35-813 574-304 416-75 738393 705103 SalePrice Grantor $272,5oo NYSTROM, BOB; NYSTROM, MICHELE $O STIRLING RANCH PROPERTYOWNERS ASSN $450,000 STtRLtNG 5UN MESA tNC $o $O STIRLINGSUNMESA,INC $O STIRLINGSUN ME5A,INC $0 STtRLTNG PROPERT|ES, INC $5,500,000 STtRLtNG PROPERTIES, INC $O STIRLING, JOHN M. $o $o $o $o $o Grantee MULLER, SHERMAN; JAMES, JANICE NYSTROM, BOB; FREEMAN, GREGORYAi... NYSTROM, BOB; NYSTROM, MICHELE STIRLING SUN MESA,INC STIRLING 5UN MESA, INC STIRLING PROPERTIES, INC 5/14/2002 5/13/2002 rl15/200? r/75/2002 7/3t200r 17/26/1999 r2/2/\985 9/t5/L983 4/7/L98t 12/14/I970 DECLARAÏION AGREEMENT SPECIALWARRANTY DEED WARRANTY DEËD PERSONAL REP DEED LETTERS RESOLUTION AFFIDAVIT QUITCLAIM DEED WARRANTY DEED 603327 6033?6 59ó038 596037 58453ó 558189 367025 345827 315719 2485 No data available forthe following modules: Buildings, Photos,5ketches. https;//qpublic.schneidercolp.com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=62068160&KeyValue=R008799 112 Ð qPublic.net'" Garfield County, CO Account Number Parcel Number Acres Land SqFt TaxArea 2019M¡ll Levy R008799 239729105024 Physical Address Owner Address OCLIPPER PL CARBONDALE MULLER, SHERMAN & JAMES, JANICE 23OOVERLOOKROAD CARBONDALECO 81ó23 2019Total Actual Value Overuiew Legerd [*] earcets Roads Parcel/Account Numbers Highways : LimitedAccess - Highway Major Road Local Road Minor Road Other Road Ramp -" Ferry Pedestrian Way Owner Name : ì Lakes&Rivers - CountyBoundary Line $250,000 Last2sales Date Price 9/24/2020 $272,5@ 6/U2019 $O 81623 32 o 011 75.5380 ù ate cr e ate d: 5 / 29 / 2A27 Last Dâtâ Uploaded: 5/29/2027 2:O4:O2 AM Deverooed bv(t ì gpþgFJgçt