HomeMy WebLinkAboutObservation of ExcavationHrrwonrr¡-Pewrar GnorucrrNlc¿.r, INc.
lv''f:ay 24, L994
5020 Road 154
Glenwood Springs, CO 81601
Fax 303 945-&454
Phone 303 94U7988
SCAIINED
Subject
D.M. Neuman Constn¡ction
Attn: Rick Davis
P.O. Box 2317
Glenwood Springs, Colorado 8L602 Job No. 194 250
Observation of Fxcavation, Proposed Guest House, 0284 Sunking Drive,
Garfield County, Colorado.
Gentlemen:
As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the
excavation at the subject site on May 13, L994 to evaluate the soils exposed for
foundation support. The findings of our work and recommendations for the foundation
design are presented in this report. The work was done in accordance with our
agreement for geotechnical engineering services to D.M. Neuman Constn¡ction, dated
May 12, 1994.
The proposed guest house will consist of a 3 car garage with an upper level living area.
The ground level will daylight from the hillside cut. Concrete walls and spread.footings
sized for a maximum bearing pressure of 1,500 psf have been assumed for building
support.
At the time of our visit to the site, the foundation excavation had been cut in one level
up to about 15 feet below the adjacent ground surface. The footings had been
constructed. The soils exposed in the bottom of the excavation consisted mainly of stiff
sandy clay. Results of swell-consolidation testing performed on sampies taken from the
site, shown on Fig. 1, indicate the soils are slightly compressible under light loading.
One of the samples showed a low expansion potential when wetted. No free water was
encountered in the excavation and the soils were slightly moist to moist.
Considering the conditions exposed in the excavation and the nature of the proposed
constn¡ction, spread footings placed on the undisturbed natural soil designed for an
allowable soil bearing pressure of 1,500 psf should be adequate for support of the
proposed guest house. S/etting of the bearing soils could result in some post
construction settlement or heave. Footings should be a minimum width of 16 inches for
continuous walls and 2 feet for columns. Loose and disturbed soils at the foundation
bearing level within the excavation should be removed to expose the undisturbed natural
soils. Exterior footings should be provided with adequate soil cover above their bearing
elevations for frost protection. Continuous foundation walls should be reinforced top
and bottom to span local anomalies such as by assuming an unsupported length of at
least 12 feet. Foundation walls acting as retaining structures should be deSigned to
resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf
for on-site soil backfill. A perimeter foundation drain should be provided to prevent
temporary buildup of hydrostatic pressure behind the walls and prevent wetting of the
D.M. Neuman Construction
May 24, 1994
Page2
lower level. Structural fill placed within floor slab areas can consist of the on-site soils
compacted to at least 957o of standard Proctor density at a moisture content near
optimum. Bacldill placed around the strucnre should be compacted and the surface
graded to prevent ponding within at least 10 feet of the building.
The recommendations submitted in this letter are based on our observation of the soils
exposed within the foundation excavation and do not include subsurface exploration to
evaluate the subsurface conditions within the loaded depth of foundation influence. This
study is based on the assumption that soils beneath the footings have equal or better
support than those exposed. The risk of foundation movement may be greater than
indicated in this report because of possible variations in the subsurface conditions. In
order to reveal the nature and extent of variations in the subsurface conditions below the
excavation, drilling would be required. It is possible the data obtained by subsurface
exploration could change the recommendations contained in this letter.
If there are any questions or if we may be of further assistance, please let us know
Sincerely
HEPTVORTH - PAWLAK GEOTECHNICAL, INC.
Steven L. Pawlak, P.E.
SLP/ro
Attachment
H.P GEOTECH
0
2
3
è.e
O
.t')
.J1
I,J.¡ú.o-
=O(J
4
iI
10
z,O
U)
o-x
L¡.l
òs
o
v).J)lrl
æ.ô-ãO(J
0
APPI_jEÐ PRESSURE - KSf
APPLIEÐ PRESSURE - Ksf
1
I Mois¡ure Content =
Ory Unit Weli¡nt '
Sample of: SAndy C I Ay
From: $slfom of ExcavatiOno
Southwest side
1E.7 percent
1AZ pcr
lllr
Compress ion
Upon l.,letting
\\l I llillil
llll
llt lllltlllttt
lt
IIII Morsrure Content . 15. 1
On7 Unrt Wergnl ' 107
Samoie of: Sandy ClAy
From: Bottom of Excavation,st side
percenl
pci
lrtilr l I llll iil
IlI illliilliltiil
r +
Expansion
Upon Wetting I ili
aIIiI
IIIII
II
HEPWOñTH.PAWLAK
GEOTECHNICAL lnc.194 250 SWELL.CONSO LI DATION TEST R ESULTS Frg. I