Loading...
HomeMy WebLinkAboutPermitGarfield Couszty Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 Permit Number SEPT-69 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 07 14 2021 Expiration Date 07/14/2022 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 284 Sun King DR, Glenwood Springs, CO 81601_ Parcel No.: 239521400005 Owner Name: Edward Vandenberg and Marcia Morgan Owner Phone: (303) 601-6667 Designed By: High Country Engineering, Inc. Designer Phone: (970) 945-8676 Number of Bedrooms: 4 Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 1,838 ftZ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by High Country Engineering, Inc. dated June 21, 2021. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve an expansion of an existing two -bedroom residence to a four -bedroom residence. The system will consist of a new, two -compartment 1,250-gallon septic tank set level with access to grade. Effluent will gravity flow to a distribution box set level with access to grade that will distribute effluent to 1,848 ftZ of STA. The new STA will consist of seven gravelless chamber trenches consisting of 22 Infiltrator Quick4 chambers per trench (154 chambers total). Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at feast 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 07/14/2021 Issued By: tarfield County Environmental Health Department Date