HomeMy WebLinkAboutPermitGarfield (01�ull
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
Permit Number SEPT-6999
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 07/28Z2021 Expiration Date 07/28/2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 7207 CR 100, Carbondale, CO 81623 Parcel No.: 239118100036
Owner Name: Mark and Kristen Favro
Designed By: Mark Favro
Owner Phone: (303) 453-9579
Designer Phone: (303) 453-9579
Number of Bedrooms: 5 Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 840 ftz
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by Mark Favro dated July 28, 2021. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The repaired OWTS will serve an existing five -bedroom residence. The system will consist of an
existing 1,250-gallon, two compartment 1,250-gallon septic tank and a new 500-gallon, single -
compartment effluent tank set level with access to grade. Effluent will gravity flow to a manifold that
will distribute effluent to 840 ft2 of STA. The new STA will consist of a four -row gravelless chamber
bed consisting of 14 ARC 36 chambers per row (56 chambers total). The infiltrative surface that the
chambers will be placed on shall be level. Inspection ports are to be installed at each corner of the
bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at Fast 48 hours prior to requesting firtal
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
in consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
—01 1*�
- ZI,
07/28/2021
Issued By: Garfield County Environmental Health Date
Department