Loading...
HomeMy WebLinkAboutFoundation Summary Letter 01.25.2021KNOTT Re ¿ÁBOnA10¡Y, r¿C Ftrens¡c Englnæring E Af ímoa¡on 18967.Neuvirth January 25,2421 Jonny Neuvirth jonny,neuvirth@govhc.com Foundation Summary Letter 84 White Peaks Lane Glenwood Springs, Colorado Dear Mr. Neuvirth You had recently contacted Knott Laboratory, LLC (Knott) and requested that it review the provided documentation and information regarding the push piers and opine on their basic layout and design. lt is Knott's understanding that there was no fínal close-out letter provided after these repairs were completed around 2017 and, more recently, a third-party has requested an engineer review the information regarding the generalpush pier installation. As a brief synopsis, Knott understands the following push-pier related events occurred based on the information you provided: r The homeowner (Mr. Neuvirth) purchased the property in April 2017. r Alliance Engineering provided a structural report dated June B, 2016 in which they observed settling of the foundation elements and recommended push piers be installed by a qualified contractor (they specifically recommended Foundation Repair of Western Colorado).. ln June 2A17, Foundation Repair of Western Colorado (Ted Munkres) and an engineer (Gary Reeder) recommended a minimum total of (31) push piers be installed around the perimeter of the foundation. Additionally, Knott understands a total of (42) piers were actually installed in an abundance of caution. The piers were spaced at no more than 6- feet on center.. ln October 2017, interior drywall repairs and adjustments to the doors and windows occuned.. According to the homeowner (Mr. Neuvirth), there are no reported visible cracks in the foundation and no indication of movement or drywall cracks as of November/December 2020.. The foundation was constructed with a 36-inch stemwallatop a 10-inch tall by Z0-inch wide footing. Knott was also provided with a sketch of the basic layout/dimensions of the residence and the pier installation logs. Based on the provided information, Knott conducted calculations based on the estimated loading conditions coupled with the worst-case 6-foot spacing of the piers along the foundation wall. lt was determined that the piers were installed at a sufficient spacing. Additionally, Knott reviewed the pier logs which indicated the piers were installed to depths ranging from 37-feet to 58-feet at approxímately 4,000 pounds per square inch. No obvious irregularities or anomalies CorporateOffice: TlB5SouthTucsonWayrCentennial,C0S0ll2-3987 o p 303.925.1900¡ f 303.925.1901 Branch 0ffices: Colorado Springs, C0 r Fort Collins, C0 r GrandJunclion, C0 o Houslon, TX r $¿¡ Äntonio, TX www,Rnottlab.c)m KñtoTT" LAEonATOßy" ¿rC Foronsic Êngineoring & Anìmotíon were noted in this data and the pier depths and installation pressures were within a relatively consistent range as would be expected. Knott understands that the residence was leveled via !e push-piers and has not since moved as there were no reports of interior distress or cracking. This factor further indicates the piers are performing as intended as they have not appreciably - moved since their time of installation. Based on this provided information and analysis, Knoti determined the push piers were installed consrsfenf with typicat industry sfandards a nd appea, to be performing as intended. Conditions and Limitations This report is intended for the sole use of the addressee, agent, or other authorized representative. The opinions stated in thís report are based upon the information and dataprovided to Knott. Should additional information become known, Knott retains the right to update any opinions, as necessary. There is no claim stated or implied that all condiiions were observed and that all defects were identified or none will develop in the future. No warranties, express, implied, or actual, are granted for any use or accuracy of the information in this report. You agree that you must evaluate and bear all risks associated with the use of the informaiion, including any reliance on the accuracy, completeness, or usefulness of such information content. Please contact Knott with any further questions. Respectfully submitted, KNOTT LABORATORY, LLC Samuel Henning, P.E. Project Manger corporale 0ffice: 7185 Soulh Tucson way o centennial, c0 80112-3987 e p 303.925.1900 o f 303.925.1901 Branch 0ffices: Colorado Springs, C0 r tofl Collins, t0 r GrandJunction, Cû . Houston, TX o San Anlonio, TX www,knottlab.com 57294 2t2t2021 Actual location of Ínstalledpiers. Does not exceed six footspacing. 42 piers total.ï{-)Nc-r To sc+LrRe4È De.rÊu¡sf6na*or