HomeMy WebLinkAboutConditions of PermitCONDIT IONS OF PERMIT
BLRE-07 -21-7 00ó
Donald Click
New Single-Family Dwelling & attached garage
47 Woodruff Rd, GWS
Elk Springs, Los Amigos, FLG 6, LoT47
1 ) ALL WORK SHALL COMply W|TH.THE 201 5 INTERNATIONAL RESIDENTIAL CODE
(t.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C,)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRICAL PERMtTTtNG AND INSPECTTONS BY COLORADO STATE ELECTRIC
BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION.
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION
AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE
AND LOCAL FIRE DISTRICT.
5) OPEN-HOLE SOTLS REPORT REOUTRED AT FOOTING INSPECTION TO VERIFY 2.OOO
PSF SOIL BEARING CAPACIry. PROVIDE COPY OF ENGINEER'S REPORT FOR
BUILDING INSPECTOR REVIEW AT FOOTING INSPECTION.
ó) A LOT TMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED
SURVEYOR, IS REQUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE -
INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS. IS IN
COMPLIANCE WITH BUILDING ENVELOPE REOUIREMENTS.
7) pRE-ENctNEERED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME
OF FRAME INSPECTION.
s) PURSUANT TO PLAT NOTE #7 (RECEPTION 578ó08), OWNER lS RESPONSIBLE FOR
THE CONTROL OF NOXIOUS WEEDS ON THE PROPERTY.