36" Direct Vent Gas Fireplace
heotilotor'
Thn fir st nøme ín fireplac e s
Please consult the manufacturer's
installation manualfor all details and
requirements before making a final
design layout decision.
DEPTI-I GLASS SIZEMODELFRONTWIDTTIBACKWIÐTHHEIGHT
Actual Fram¡ng Actual Framing Actual Framing Actual Fram¡ng
48-1/4 41-3/4 42 17-1/8 18-1/4
35-1/2x12-1/2CBAVE4836
46-3/16 48-1/4 46-3/16
TOP
6" [11
1 t25l
{
I 8-5/8'
14 17-1t8"
8-9/16'[218]
ON APPLIANCE
1t2" 11257)
39-114"
42-'v2"
t1
63'[1600]
36-5/8"41-3tA',Ie30l [1061]
24-1t2"[3971
23-3t4"
16031 2-3t8"
1601
I 12251 [1
8-9/t6'7 6'
12181
11841 GAS ACCESS
ELECTRIGAL ACCESS 12181
t70l
LEFT FRONT RIGHT
BEFORE FRAMING, PLEASE NOTE:
A minimum of 18" of verticalventing is required before attaching any elbow to the appliance.
T----ï."-r
Specifications Crave CRAVE4836
Additional informat¡on can be found online at \M.heatilator.com
Decorative Front Dimensions and Framing Crave CRAVE4836
t
FRONT DIMENSIONS
Ir6l
37-3¡6"fe45l
lt024l
CLEAN FACE TRIM
a Rectangular holes on bottom
of access panel should be
covered.
Approved for 0"-4" finishing
material on inside fit method
lf finishing materials are 0-1"
thick, the outer trim ring
should be adjusted out so
that the trim ring overlaps
the finishing material. This
is intended to provide the
cleanest look.
lf finishing materials are 1-4"
thick, installthe trim ring all
the way in. Finishing
materials may not extend
past the outside edge of the
trim ring.
FOUR SQUARE FRONT
Rectangular holes on bottom of
access panel must be exposed.
ONLY approved for 0"-1"
finishing material on overlap fit
method
t5431
ILLUSION FRONT
Rectangular holes on bottom of
access panel must be exposed.
ONLY approved for 0"-1"
finishing material on overlap fit
method
27-5116',
]--
a
16351 I
Ie33l l1
[1
a
aa
a
a
il
FINISHED OPENING DIMENSIONS
15-314
t4001
17-1t4
t4381
INSIDE FIT METHOD
(CLEAN FACE TRIM)
OVERLAP FIT METHOD
(FOUR SQUARE, tLLUSION)
s9-1/8'[9e4]
þ
ree4+:39-1/8"
heotiloor
T'læ first ruru in fireplae e s
pecificat¡ons Crave CRAVE4836
Refer to install manual for hearth,
mantel and wall project¡on
informat¡on.
lfa Passive Heat Heat-Zone or
Heat Out will be ¡nstalled, refer
install manual for instructions.
l8 in. (457 mm) required when
Pass¡ve HeatSide Djs(harge K¡t is
installed, Refer to the Pãss¡vê Hêât
kit instruct¡ons for more informåt¡on.
APPLIANCE LOCATION
WALL PENETRATION
insulation or
other material
10'2"
OJ
V
64"
[1 6261 'Shows center of vent framing
hole for top vent¡ng. Center of hole
is 1" [25] above center of horizonlal
vent pjpe.
MANTEL PROJECTIONS - COMBUSTIBLE
All measurements in inches.
WITHOUT
PASSIVE
HEAT
WTH
PASSIVE
HEAT
----l;l
t0
Of
'f
E APPLIAÑCE OPENINC
Mêâ.ûr€m.nttom ¡op odgô oÞãntng
lo boltom otappllanco = 24i¡2 lN.
t.a!ùr.ña¡l from top €doo ôt op.nl¡g
Io htlon oIôþ!llùc. - 24if lx.
MANTEL PROJECTIONS . NON.COMBUSTIBLE
FRAMING DIMENSIONS
HADER
DEPTH"
APPLIANCE MAY BE INSTALLED OFF OF FLOOR*'
' Adjust fram¡ng d¡ûensjons for inl€rior sheathing (such âs sheetrock)
" Headerdeplh not to exceed 3ll2".i" lf âppliance is inslâlled offlhe lìoof, mainlâin required deârânc€s to @mbuslibtes
Conslruct plaforñ in ac@rdânæ wjth loæl building ødes.
CLEARANCES TO COMBUSTIBLES
MANTEL LEG/WALL PROJ ECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
PRODUCT LISTING CODES
US ANSt 221 .88-201 7
CAN csA 2.33-2017
.@u.urro UL307B
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury
Add¡tional ¡nformation can be found onl¡ne at www.healilatorcom
laeotilotor.
The frrst ruru infrreplw
Lakev¡lle, MN Phone: (800) 927-6841
,@urro'ro
il
1" l25l
I
I
31',17871
Oæning lo
Ceil¡ns
1" f25l
2
INSIDE FIT
1l
NOTE:measurements in ¡nches.
OFIHEÁ'PThXCEO'Ëf,'NG
_---;
13
11
10
OVERLAP FIT
tê.!u16ûôñt lrom rop.d9å of ôponrñg
lo boloñ otåDDÌ.nc. r2¿¡l2 lN.M.â.ùr€m.ñr f om rop ådg. ótóp.n¡ng
l. bolloñ olrtpll¡nc. ; 2¡ll2 l¡.
Seê Appliance d¡mension d¡agram
¡n ¡nstall manual - Dimension B
Top View
max¡mum
OPENING
Noter Clearance from
opening to
perpendicular wâll
UNLII\4ITED
FIREPLACE OPENING
Notê: Cleârance from
opening to
perpendjcula¡ wall
Acceptable on both s¡des ofopeniñg
Web: www.heatilator.com
GS/HÍUCRAVE4836_0420