HomeMy WebLinkAboutFireplace SpecsCrave4836 36" Direct Vent Gas Fireplace heotilotor' Thn fir st nøme ín fireplac e s Please consult the manufacturer's installation manualfor all details and requirements before making a final design layout decision. DEPTI-I GLASS SIZEMODELFRONTWIDTTIBACKWIÐTHHEIGHT Actual Fram¡ng Actual Framing Actual Framing Actual Fram¡ng 48-1/4 41-3/4 42 17-1/8 18-1/4 35-1/2x12-1/2CBAVE4836 46-3/16 48-1/4 46-3/16 TOP 6" [11 1 t25l { I 8-5/8' 14 17-1t8" 8-9/16'[218] ON APPLIANCE 1t2" 11257) 39-114" 42-'v2" t1 63'[1600] 36-5/8"41-3tA',Ie30l [1061] 24-1t2"[3971 23-3t4" 16031 2-3t8" 1601 I 12251 [1 8-9/t6'7 6' 12181 11841 GAS ACCESS ELECTRIGAL ACCESS 12181 t70l LEFT FRONT RIGHT BEFORE FRAMING, PLEASE NOTE: A minimum of 18" of verticalventing is required before attaching any elbow to the appliance. T----ï."-r Specifications Crave CRAVE4836 Additional informat¡on can be found online at \M.heatilator.com Decorative Front Dimensions and Framing Crave CRAVE4836 t FRONT DIMENSIONS Ir6l 37-3¡6"fe45l lt024l CLEAN FACE TRIM a Rectangular holes on bottom of access panel should be covered. Approved for 0"-4" finishing material on inside fit method lf finishing materials are 0-1" thick, the outer trim ring should be adjusted out so that the trim ring overlaps the finishing material. This is intended to provide the cleanest look. lf finishing materials are 1-4" thick, installthe trim ring all the way in. Finishing materials may not extend past the outside edge of the trim ring. FOUR SQUARE FRONT Rectangular holes on bottom of access panel must be exposed. ONLY approved for 0"-1" finishing material on overlap fit method t5431 ILLUSION FRONT Rectangular holes on bottom of access panel must be exposed. ONLY approved for 0"-1" finishing material on overlap fit method 27-5116', ]-- a 16351 I Ie33l l1 [1 a aa a a il FINISHED OPENING DIMENSIONS 15-314 t4001 17-1t4 t4381 INSIDE FIT METHOD (CLEAN FACE TRIM) OVERLAP FIT METHOD (FOUR SQUARE, tLLUSION) s9-1/8'[9e4] þ ree4+:39-1/8" heotiloor T'læ first ruru in fireplae e s pecificat¡ons Crave CRAVE4836 Refer to install manual for hearth, mantel and wall project¡on informat¡on. lfa Passive Heat Heat-Zone or Heat Out will be ¡nstalled, refer install manual for instructions. l8 in. (457 mm) required when Pass¡ve HeatSide Djs(harge K¡t is installed, Refer to the Pãss¡vê Hêât kit instruct¡ons for more informåt¡on. APPLIANCE LOCATION WALL PENETRATION insulation or other material 10'2" OJ V 64" [1 6261 'Shows center of vent framing hole for top vent¡ng. Center of hole is 1" [25] above center of horizonlal vent pjpe. MANTEL PROJECTIONS - COMBUSTIBLE All measurements in inches. WITHOUT PASSIVE HEAT WTH PASSIVE HEAT ----l;l t0 Of 'f E APPLIAÑCE OPENINC Mêâ.ûr€m.nttom ¡op odgô oÞãntng lo boltom otappllanco = 24i¡2 lN. t.a!ùr.ña¡l from top €doo ôt op.nl¡g Io htlon oIôþ!llùc. - 24if lx. MANTEL PROJECTIONS . NON.COMBUSTIBLE FRAMING DIMENSIONS HADER DEPTH" APPLIANCE MAY BE INSTALLED OFF OF FLOOR*' ' Adjust fram¡ng d¡ûensjons for inl€rior sheathing (such âs sheetrock) " Headerdeplh not to exceed 3ll2".i" lf âppliance is inslâlled offlhe lìoof, mainlâin required deârânc€s to @mbuslibtes Conslruct plaforñ in ac@rdânæ wjth loæl building ødes. CLEARANCES TO COMBUSTIBLES MANTEL LEG/WALL PROJ ECTIONS COMBUSTIBLE OR NON-COMBUSTIBLE PRODUCT LISTING CODES US ANSt 221 .88-201 7 CAN csA 2.33-2017 .@u.urro UL307B Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury Add¡tional ¡nformation can be found onl¡ne at www.healilatorcom laeotilotor. The frrst ruru infrreplw Lakev¡lle, MN Phone: (800) 927-6841 ,@urro'ro il 1" l25l I I 31',17871 Oæning lo Ceil¡ns 1" f25l 2 INSIDE FIT 1l NOTE:measurements in ¡nches. OFIHEÁ'PThXCEO'Ëf,'NG _---; 13 11 10 OVERLAP FIT tê.!u16ûôñt lrom rop.d9å of ôponrñg lo boloñ otåDDÌ.nc. r2¿¡l2 lN.M.â.ùr€m.ñr f om rop ådg. ótóp.n¡ng l. bolloñ olrtpll¡nc. ; 2¡ll2 l¡. Seê Appliance d¡mension d¡agram ¡n ¡nstall manual - Dimension B Top View max¡mum OPENING Noter Clearance from opening to perpendicular wâll UNLII\4ITED FIREPLACE OPENING Notê: Cleârance from opening to perpendjcula¡ wall Acceptable on both s¡des ofopeniñg Web: www.heatilator.com GS/HÍUCRAVE4836_0420