Loading...
HomeMy WebLinkAboutSubsoil Study 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado PRELIMINARY SUBSOIL STUDY FOR FOUNDATION DESIGN PROPOSED HOUSE, ADU/STORAGE AND BARN BUCK POINT RANCH 723 COUNTY ROAD 121 GARFIELD COUNTY, COLORADO PROJECT NO. 21-7-291 MAY 24, 2021 PREPARED FOR: SGJD, LLC ATTN: JIM DETTERICK 4894 MEADOW LANE VAIL, COLORADO 81657 jim.detterick@mac.com Kumar & Associates, Inc. ® Project No. 21-7-291 TABLE OF CONTENTS PURPOSE AND SCOPE OF STUDY ....................................................................................... - 1 - PROPOSED CONSTRUCTION ................................................................................................ - 1 - SITE CONDITIONS ................................................................................................................... - 1 - SUBSIDENCE POTENTIAL ..................................................................................................... - 2 - FIELD EXPLORATION ............................................................................................................ - 2 - SUBSURFACE CONDITIONS ................................................................................................. - 3 - FOUNDATION BEARING CONDITIONS .............................................................................. - 3 - DESIGN RECOMMENDATIONS ............................................................................................ - 4 - FOUNDATIONS .................................................................................................................... - 4 - FOUNDATION AND RETAINING WALLS ....................................................................... - 5 - FLOOR SLABS ...................................................................................................................... - 6 - UNDERDRAIN SYSTEM ..................................................................................................... - 7 - PAVEMENT SECTION ......................................................................................................... - 7 - SURFACE DRAINAGE ......................................................................................................... - 8 - LIMITATIONS ........................................................................................................................... - 8 - FIGURE 1 - LOCATION OF EXPLORATORY BORINGS FIGURE 2 - LOGS OF EXPLORATORY BORINGS FIGURES 3 AND 4 - SWELL-CONSOLIDATION TEST RESULTS FIGURES 5 AND 6 - GRADATION TEST RESULTS TABLE 1- SUMMARY OF LABORATORY TEST RESULTS Kumar & Associates, Inc. ® Project No. 21-7-291 PURPOSE AND SCOPE OF STUDY This report presents the results of a subsoil study for a proposed house, ADU and storage building and barn to be located at Buck Point Ranch, 723 County Road 121, Garfield County, Colorado. The project site is shown on Figure 1. The purpose of the study was to develop recommendations for the foundation design. The study was conducted in accordance with our agreement for geotechnical engineering services to SGJD, LLC dated March 22, 2021. A field exploration program consisting of exploratory borings was conducted to obtain information on the subsurface conditions. Samples of the subsoils and bedrock obtained during the field exploration were tested in the laboratory to determine their classification, compressibility or swell and other engineering characteristics. The results of the field exploration and laboratory testing were analyzed to develop recommendations for foundation types, depths and allowable pressures for the proposed foundations. This report summarizes the data obtained during this study and presents our conclusions, design recommendations and other geotechnical engineering considerations based on the proposed construction and the subsurface conditions encountered. PROPOSED CONSTRUCTION The proposed house will be a one-story structure over walkout basement level with attached garage. The proposed ADU and storage building will be a tall single-story structure with garage door access along the front of the building. The proposed barn will be a single-story structure. The proposed ground floors will be structural over crawlspace for the living areas of the house and slab-on-grade for the garage, barn and ADU/storage building. Grading for the structures is assumed to be relatively minor with cut depths between about 3 to 8 feet. We assume relatively light foundation loadings, typical of the proposed type of construction. If building loadings, location or grading plans change significantly from those described above, we should be notified to re-evaluate the recommendations contained in this report. SITE CONDITIONS The subject site was vacant at the time of our field exploration. Several 2-track roads cross the site and were used for access. The ground surface generally slopes moderately down to the south at a grade of about 10 percent. A grassy and marshy area is on the west side of the site and an irrigation ditch runs approximately 150 feet west of the proposed house. Vegetation consists of - 2 - Kumar & Associates, Inc. ® Project No. 21-7-291 grass, weeds and sagebrush with stands of oak brush and cottonwood trees around the marsh area. SUBSIDENCE POTENTIAL Bedrock of the Pennsylvanian age Eagle Valley Evaporite underlies the subject site. These rocks are a sequence of gypsiferous shale, fine-grained sandstone and siltstone with some massive beds of gypsum and limestone. There is a possibility that massive gypsum deposits associated with the Eagle Valley Evaporite underlie portions of the lot. Dissolution of the gypsum under certain conditions can cause sinkholes to develop and can produce areas of localized subsidence. During previous work in the area, several sinkholes were observed scattered throughout Garfield and Eagle Counties. These sinkholes appear similar to others associated with the Eagle Valley Evaporite in areas of the Eagle Valley. Sinkholes were not observed in the immediate area of the subject lot. No evidence of cavities was encountered in the subsurface materials; however, the exploratory borings were relatively shallow, for foundation design only. Based on our present knowledge of the subsurface conditions at the site, it cannot be said for certain that sinkholes will not develop. The risk of future ground subsidence at Buck Point Ranch throughout the service life of the proposed residence, in our opinion, is low; however, the owner should be made aware of the potential for sinkhole development. If further investigation of possible cavities in the bedrock below the site is desired, we should be contacted. FIELD EXPLORATION The field exploration for the project was conducted on April 28, 2021. Five exploratory borings were drilled at the locations shown on Figure 1 to evaluate the subsurface conditions. The borings were advanced with 4-inch diameter continuous flight augers powered by a truck- mounted CME-45B drill rig. The borings were logged by a representative of Kumar & Associates, Inc. Samples of the subsoils were taken with 1⅜-inch and 2-inch I.D. spoon samplers. The samplers were driven into the subsoils at various depths with blows from a 140-pound hammer falling 30 inches. This test is similar to the standard penetration test described by ASTM Method D-1586. The penetration resistance values are an indication of the relative density or consistency of the subsoils and hardness of the bedrock. Depths at which the samples were taken and the penetration resistance values are shown on the Logs of Exploratory Borings, Figure 2. The samples were returned to our laboratory for review by the project engineer and testing. - 3 - Kumar & Associates, Inc. ® Project No. 21-7-291 SUBSURFACE CONDITIONS Graphic logs of the subsurface conditions encountered at the site are shown on Figure 2. The subsoils consist of about ½ to 2 feet of topsoil overlying dense, clayey sandy gravel down to between 8 and 23 feet deep where very stiff to hard, sandy clay was encountered down to between 14 and 31 feet deep. In the area of the house, dense silt sand was encountered in Boring 2 from 14 to 19 feet deep overlying weathered siltstone/sandstone bedrock down to 31 feet deep. In the area of the barn in Boring 4, very stiff, expansive clay soil was encountered below the gravel from 8 to 18 feet deep overlying dense, silty sandy gravel down to 26 feet deep. In the ADU/storage building area, in Boring 5, very stiff clay was encountered below the topsoil from 1½ to 4½ feet deep underlain by dense, clayey sandy gravel from 4½ to 23 feet deep and very stiff, sandy clay from 23 to 31 feet deep. Laboratory testing performed on samples obtained from the borings included natural moisture content and density, Atterberg limits and gradation analyses. Results of swell-consolidation testing performed on relatively undisturbed drive samples, presented on Figures 3 and 4, indicate low to moderate compressibility under existing low moisture conditions and light loading and a nil to high expansion potential when wetted under constant light surcharge. Results of gradation analyses performed on small diameter drive samples (minus 1½-inch fraction) of the coarse granular subsoils are shown on Figures 5 and 6. The laboratory testing is summarized in Table 1. Free water was encountered in Boring 2 at a depth of 15 feet and in Boring 5 at a depth of 30½ feet at the time of drilling and the upper subsoils were slightly moist to moist. FOUNDATION BEARING CONDITIONS The bearing conditions were variable across the site and we recommend additional borings be drilled to verify the soil conditions at each structure once building elevations have been determined. For preliminary planning purposes, the residence can be founded on the upper gravel soils. We believe the garage can be founded on spread footings bearing on the natural granular soils with a risk of movement. We recommend the barn be founded on spread footings bearing on the natural granular soils. We recommend the ADU/storage building be supported on spread footings bearing on the natural granular soils below the clay soils or compacted structural fill placed on the natural gravel soils. - 4 - Kumar & Associates, Inc. ® Project No. 21-7-291 PRELIMINARY DESIGN RECOMMENDATIONS FOUNDATIONS Considering the subsurface conditions encountered in the exploratory borings and the nature of the proposed construction, we believe the buildings can be founded with spread footings bearing on the natural granular soils or compacted structural fill with a risk of movement. Once building bearing elevations have been developed, additional borings will need to be drilled at each structure to verify bearing conditions. The design and construction criteria presented below should be observed for a spread footing foundation system. 1) Footings placed on the undisturbed natural granular soils or compacted structural fill should be designed for an allowable bearing pressure of 1,500 to 3,000 psf. Based on experience, we expect movement of footings designed and constructed as discussed in this section will be about 1 inch or less. Additional, post construction, movement could occur if the bearing soils become wetted. The magnitude of additional movement would depend on the depth and extent of wetting but could be on the order of about 1 inch. 2) The footings should have a minimum width of 16 inches for continuous walls and 2 feet for isolated pads. 3) Exterior footings and footings beneath unheated areas should be provided with adequate soil cover above their bearing elevation for frost protection. Placement of foundations at least 36 inches below exterior grade is typically used in this area. 4) Continuous foundation walls should be heavily reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 14 feet. Foundation walls acting as retaining structures should also be designed to resist lateral earth pressures as discussed in the "Foundation and Retaining Walls" section of this report. 5) In the house foundation excavation, the deeper footing areas may need to be sub-excavated a minimum of 4 feet below proposed footing level. The exposed subgrade should be moisture conditioned and compacted prior to placing structural fill. Structural fill can consist of the onsite granular materials devoid of organics and oversized (plus 6-inch) rock, or imported granular material such as CDOT Class 6 road base. Structural fill should be compacted to 98 percent of maximum standard Proctor density at a moisture content near optimum. - 5 - Kumar & Associates, Inc. ® Project No. 21-7-291 Structural fill should extend laterally beyond the edges of footings at a slope of ½ horizontal to 1 vertical. 6) Topsoil, clay soils and any loose disturbed soils should be removed and the footing bearing level extended down to the relatively dense natural granular soils in the barn and ADU/Storage buildings. The exposed soils in footing area should then be moistened and compacted. If water seepage is encountered, the footing areas should be dewatered before concrete placement. 7) A representative of the geotechnical engineer should observe all footing excavations prior to concrete placement to evaluate bearing conditions. FOUNDATION AND RETAINING WALLS Foundation walls and retaining structures which are laterally supported and can be expected to undergo only a slight amount of deflection should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 50 pcf for backfill consisting of the on-site, more granular soils. Cantilevered retaining structures which are separate from the buildings and can be expected to deflect sufficiently to mobilize the full active earth pressure condition should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 45 pcf for backfill consisting of the on-site granular soils. All foundation and retaining structures should be designed for appropriate hydrostatic and surcharge pressures such as adjacent footings, traffic, construction materials and equipment. The pressures recommended above assume drained conditions behind the walls and a horizontal backfill surface. The buildup of water behind a wall or an upward sloping backfill surface will increase the lateral pressure imposed on a foundation wall or retaining structure. An underdrain should be provided to prevent hydrostatic pressure buildup behind walls. Backfill should be placed in uniform lifts and compacted to at least 90% of the maximum standard Proctor density at a moisture content near optimum. Backfill placed in pavement and walkway areas should be compacted to at least 95% of the maximum standard Proctor density. Care should be taken not to overcompact the backfill or use large equipment near the wall, since this could cause excessive lateral pressure on the wall. Some settlement of deep foundation wall backfill should be expected, even if the material is placed correctly, and could result in distress to facilities constructed on the backfill. The lateral resistance of foundation or retaining wall footings will be a combination of the sliding resistance of the footing on the foundation materials and passive earth pressure against - 6 - Kumar & Associates, Inc. ® Project No. 21-7-291 the side of the footing. Resistance to sliding at the bottoms of the footings can be calculated based on a coefficient of friction of 0.45. Passive pressure of compacted backfill against the sides of the footings can be calculated using an equivalent fluid unit weight of 400 pcf. The coefficient of friction and passive pressure values recommended above assume ultimate soil strength. Suitable factors of safety should be included in the design to limit the strain which will occur at the ultimate strength, particularly in the case of passive resistance. Fill placed against the sides of the footings to resist lateral loads should be a granular material compacted to at least 95% of the maximum standard Proctor density at a moisture content near optimum. FLOOR SLABS The on-site clay soils possess an expansion potential and slab heave could occur if the subgrade soils were to become wet. Slab-on-grade construction may be used provided precautions are taken to limit potential movement and the risk of distress to the building is accepted by the owner. A positive way to reduce the risk of slab movement, which is commonly used in the area, is to construct structurally supported floors over crawlspace. To reduce the effects of some differential movement, nonstructural floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Interior non-bearing partitions resting on floor slabs should be provided with a slip joint at the bottom of the wall so that, if the slab moves, the movement cannot be transmitted to the upper structure. This detail is also important for wallboards, stairways and door frames. Slip joints which will allow at least 1½-inches of vertical movement are recommended. Floor slab control joints should be used to reduce damage due to shrinkage cracking. Slab reinforcement and control joints should be established by the designer based on experience and the intended slab use. A minimum 4-inch layer of free-draining gravel should be placed immediately beneath basement level slabs-on-grade. This material should consist of minus 2-inch aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve. The free-draining gravel will aid in drainage below the slabs and should be connected to the perimeter underdrain system. Required fill beneath slabs can consist of the on-site gravelly soils or a suitable imported granular material, excluding topsoil and oversized rocks. The fill should be spread in thin horizontal lifts, adjusted to at or above optimum moisture content, and compacted to at least 95% of the maximum standard Proctor density. All vegetation, topsoil and loose or disturbed soil should be removed prior to fill placement. - 7 - Kumar & Associates, Inc. ® Project No. 21-7-291 The above recommendations will not prevent slab heave if the expansive soils underlying slabs- on-grade become wet. However, the recommendations will reduce the effects if slab heave occurs. All plumbing lines should be pressure tested before backfilling to help reduce the potential for wetting. UNDERDRAIN SYSTEM Although free water encountered during our exploration was below the lowest proposed grade, it has been our experience in the area and where clay soils are present that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below-grade construction, such as retaining walls, crawlspace and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free-draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1% to a suitable gravity outlet. Free-draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 1½ feet deep. In areas where clay soils are present, an impervious membrane such as 20 mil PVC should be placed beneath the drain gravel in a trough shape and attached to the foundation wall with mastic to prevent wetting of the bearing soils. PAVEMENT SECTION We understand a gravel section is proposed for the access driveway. We were provided preliminary designs from SGM for review. The proposed gravel section consists of 4 inches of CDOT Class 6 road base placed on 8 inches of CDOT Class 2 subbase with 12 inches of compacted native material below. For the granular subgrade soils encountered in Boring 3 in the new driveway area, we believe this gravel section is sufficient for the proposed driveway. In areas where fine-grained subgrade soils are encountered, we recommend increasing the gravel section to 6 inches of road base placed on 12 inches of subbase for the proposed driveway. Required fill to establish design subgrade level can consist of the on-site granular soils or suitable imported granular soils such as CDOT Class 2 structural fill. Prior to fill placement the subgrade should be scarified to a depth of 8 inches, adjusted to near optimum moisture and compacted to at least 95% of standard Proctor density. In soft or wet areas, the subgrade may - 8 - Kumar & Associates, Inc. ® Project No. 21-7-291 require drying or stabilization prior to fill placement. A geogrid and/or sub-excavation and replacement with aggregate base soils may be needed for the stabilization. The subgrade should be proofrolled. Areas that deflect excessively should be corrected before placing pavement materials. SURFACE DRAINAGE Proper surface drainage may be critical to the long-term performance of the proposed buildings. The following drainage precautions should be observed during construction and maintained at all times after the buildings have been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. Drying could increase the expansion potential of the soils. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in paved areas. Free-draining wall backfill should be covered with filter fabric and capped with about 2 feet of the on-site soils to reduce surface water infiltration. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Landscaping which requires regular heavy irrigation should be located at least 10 feet from foundation walls. LIMITATIONS This preliminary study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory borings drilled at the locations indicated on Figure 1, the proposed type of construction and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. We recommend that additional borings be drilled at each building location once the foundation elevations have been determined. Kumar & Associates Kumar & Associates Kumar & Associates Kumar & Associates Kumar & Associates Kumar & Associates TABLE 1 SUMMARY OF LABORATORY TEST RESULTS Project No. 21-7-291 SAMPLE LOCATION NATURAL MOISTURE CONTENT NATURAL DRY DENSITY GRADATION PERCENT PASSING NO. 200 SIEVE ATTERBERG LIMITS EXPANSION PRESSURE EXPANSION SOIL TYPE BORING DEPTH GRAVEL SAND LIQUID LIMIT PLASTIC INDEX (%) (%) (ft) (%) (pcf) (%) (%) (psf) (%) 1 10 23.5 96 50 30 Clay 15 17.3 112 -- -- Sandy Clay 2 3 & 5 combined 6.2 50 35 15 Clayey Very Sandy Gravel 15 19.8 106 67 Sandy Silt 25 14.7 119 59 Very Sandy Silt 30 15.5 117 55 Sand and Silt 3 5 3.2 44 40 16 Clayey Gravel and Sand 4 3 & 5 combined 4.9 45 38 17 Clayey Gravel and Sand 10 15.4 112 19,000 3.5 Sandy Silt 20 7.7 115 16 Silty Gravel and Sand 5 3 11.3 111 12,000 5.5 Sandy Clay 10 & 15 combined 10.7 35 39 26 Clayey Gravel and San