Loading...
HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT BLRE-0ó -20-ó323 Wayne Blotske Addition Living space plus new attached gara ge to aq existing tri-level S/F dwelling u n it 34671 Hwy ó & 24, Slt Parcel Number: 21791 1 100553 1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE (r.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C,C,) 2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD, ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. 5) PRE-FABRTCATED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION. ó) opEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR (2,500 PSF). 7) SEPTIC SYSTEM REVIEWAPPROVALS: PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINALAPPROVAL / SIGN-OFF FROM GARFIELD COUNry'S PUBLIC HEALTH DEPT. CONTACT (970) 945.6614 EXT. 8150 AND REFERENCE EXISTING SEPT.OS-I3.2936. PLANS EXAMINER CONFIRMS PROPOSED FLOOR PLAN SHOWS ATOTAL OF (4) BEDROOMS.