HomeMy WebLinkAboutOWTS Design 09.23.20212789 Riverside Parkway
Grand Junction, Colorado 81501
Phone: 970-255-8005
Info@huddlestonberry.com
September 23, 2021
Project#02293-0001
Lucky Seven LLC
336 Evergreen Drive
Rifle, Colorado 81650
Attention: Mr. Javier Orozco
Subject: OWTS Design
10991 CR 320
Rifle, Colorado
Dear Mr. Orozco,
At your request, Huddleston-Berry Engineering & Testing, LLC completed design of an Onsite
Wastewater Treatment System (OWTS) for a single-family residence at 10991 CR 320 in Rifle,
Colorado. The site location is shown on Figure 1 – Site Location Map. A site plan is included as
Figure 2.
Site Description
At the time of the investigation, a garage structure occupied the northwest portion of the site. The
remainder of the site was open and gradually sloping down towards the north. Site topography is
shown on Figure 2. Vegetation consisted of weeds, grasses, and small to large trees. The site
was bordered to the north by open land, to the west and east by residential properties, and to the
south by CR 320.
Subsurface Investigation
In order to evaluate the subsurface conditions at the site, four test pits were excavated at the site.
The locations of the test pits are shown on Figure 2. Copies of the test pit logs are included in
Appendix A.
As indicated on the logs, the subsurface conditions at the site were consistent. The test pits
generally encountered 1.0 foot of loam above tan sandy loam soils with trace gravel and cobbles
to the bottoms of the excavations. The soils were massive, structureless, and firm. Groundwater
was not encountered in the subsurface at the time of the investigation. In general, HBET
believes that the seasonal high groundwater elevation is deeper than 8.0 feet at this site.
Onsite Wastewater Treatment System
Seepage Bed Design
The design of the absorption system generally follows the requirements of the Garfield County
Department of Public Works as outlined in the Garfield County On-Site Wastewater Treatment
System Regulations, effective July 2018. The proposed construction at the site is anticipated to
include a three-bedroom home.
10991 CR 320
#02293-0001
09/23/21
Z:\2008 ALL PROJECTS\02293 - Lucky Seven LLC\02293-0001 10991 CR 320\200 - Geo\02293-0001 LR092321.doc 2
Based upon visual-tactile evaluation of the site soils in accordance with the regulations, a Long-
Term Acceptance Rate (LTAR) of 0.5 will be utilized for the absorption field design. Infiltrator
Systems Quick4 Standard Chambers are proposed. The daily flow of the sewage disposal system
is calculated below, and a plan and profile of the absorption system are shown on Figure 3.
Average Daily Flow = (6 persons)(75 GPD/person)
= 450 GPD
Soil Treatment Area = (450 GPD / 0. 5) = 900 Square Feet
Adjusted Soil Treatment Area = (900 SF)(1.2)(0.7) = 756 Square Feet
# of Quick4 Chambers = (756 / 12) = 63 Chambers; Use 64 Chambers
System Installation
The installation of the septic tank, plumbing lines, Infiltrators, etc. should be completed in
accordance with the Garfield County On-Site Wastewater Treatment System Regulations and
Infiltrator Systems, Inc. specifications. In addition, the following construction procedures are
recommended:
The septic tank and distribution box should be placed level over native soils that have
been scarified to a depth of 8 to 12 inches, moisture conditioned, and recompacted to
a minimum of 95% of the standard Proctor maximum dry density, within ±2% of
optimum moisture content. However, up to 3-inches of washed rock or pipe bedding
passing the 1-inch sieve may be used as a leveling course under the septic tank and/or
distribution box.
The bottoms of trenches and backfill around the septic tank and distribution box
which will support sewer or effluent lines should be compacted to at least 90 percent
of the standard Proctor maximum dry density, within ±2% of optimum moisture
content. Pipe bedding should have a maximum particle size of 1-inch.
Vehicular or heavy equipment traffic and placement of structures should not encroach
within 10 feet of the septic tank or distribution box.
Inspection Schedule
Huddleston-Berry Engineering & Testing LLC should be retained to monitor the construction of
the OWTS. The following schedule of observation and/or testing should be followed:
Observe the absorption bed excavation prior to placement of Infiltrator chambers.
Observe placement of the septic tank, distribution box, and all connecting sewer and
effluent lines prior to backfill. Verify proper fall between inverts.
Observe and verify installation of the absorption bed prior to placement of cover and
backfill.
In conformance with Garfield County regulations, HBET will be required to provide the Garfield
County Health Department with documentation certifying that the OWTS was placed in
conformance to the plan and profile and Garfield County regulations.
General Notes
The OWTS design was based upon the results of the subsurface investigation and on our local
experience. The design is valid only for the proposed construction.
10991 CR 320
#02293-0001
09/23/21
Z:\2008 ALL PROJECTS\02293 - Lucky Seven LLC\02293-0001 10991 CR 320\200 - Geo\02293-0001 LR092321.doc 3
We are pleased to be of service to your project. Please contact us if you have any questions or
comments regarding the contents of this report.
Respectfully Submitted:
Huddleston-Berry Engineering and Testing, LLC
Michael A. Berry, P.E.
Vice President of Engineering
09/23/21
3,203 ft
2789 Riverside Parkway
Grand Junction, CO 81501
Project No.: 02293-0001
Date: 09/23/21
By: MAB
10991 CR 320
PARCEL#217720100010
FIGURE 2 - SITE PLANTEST PIT
C.I. = 2 FT
SCALE: 1" = 60'
**NOTE:TANK AND BED LOCATIONS APPROXIMATE AND MAY SHIFT SOME DURING
CONSTRUCTION BASED UPON SITE TOPOGRAPHY, OWNER PREFERENCE, AND/OR OTHER
FACTORS AS LONG AS APPLICABLE SETBACKS ARE MET. ACTUAL LOCATION OF TANK AND
BED WILL BE INDICATED ON AS-BUILT DRAWINGS.**
WATER LINE
LAST CHANCE DITCH
NEW HOME
REPAIR
AREA
MINIMUM 1,000
GALLON TANK
STA
53405330532053505322532453265328533253345336533853425344534653485352TP-1
TP-3
TP-2
TP-4
~48'
64'
12'
~20' (10' MIN)
~78'~20'
~9'
~70'6"
~53'
~171'6"
~117'
~205'
~240'
NEW DRIVEWAY
~78'
~46'
~31'
~24'
~25'~132'
EXISTING STRUCTURES
09/23/21
2789 Riverside Parkway
Grand Junction, CO 81501
Project No.: 02293-0001
Date: 09/23/21
By: MAB
MINIMUM SETBACKS
(UNITS = FT)
**OTHER SETBACKS NOT LISTED HERE SHOULD BE IN ACCORDANCE WITH GARFIELD COUNTY OWTS REGULATIONS
**USE SWEEP 90'S OR
TWO 45'S AT 90
DEGREE BENDS**
DETAIL AREA
SCALE: 1" = 20'
10991 CR 320
PARCEL#217720100010
FIGURE 3 - SEPTIC SYSTEM
DETAILS
64'
12'
5' MIN
20' MIN
4-INCH DIAMETER SEWER AND
EFFLUENT PIPE MEETING ASTM
D1785, SCHEDULE 40 OR SDR 35
DISTRIBUTION BOX THAT
ENSURES EVEN DISTRIBUTION
OF EFFLUENT
SEPTIC TANK WITH
MINIMUM 1,000
GALLON CAPACITY
WATER
LINE
INFILTRATOR SYSTEMS QUICK4
STANDARD CHAMBERS
NEW HOME
INSPECTION PORTS
5' MIN
GENERALIZED SYSTEM PROFILE
GENERALIZED BED PROFILE
COVER SOIL; NATIVE SOILS OR OTHER SUITABLE
TOPSOIL. GRADE TO CARRY SURFACE WATER
AWAY FROM BED.
NONWOVEN, NEEDLE PUNCHED, GEOTEXTILE
FABRIC IMMEDIATELY ABOVE CHAMBERS
INFILTRATOR SYSTEMS QUICK4
STANDARD CHAMBERS
09/23/21
APPENDIX A
Typed Test Pit Logs
1.0
7.0
Loam
Sandy Loam, trace gravel and cobbles, tan, massive, structureless, firm
Bottom of test pit at 7.0 feet.
NOTES
GROUND ELEVATION
LOGGED BY SD
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION dry
AT END OF EXCAVATION dry
AFTER EXCAVATION ---
TEST PIT SIZE
EXCAVATION CONTRACTOR Hi-River GROUND WATER LEVELS:
CHECKED BY MAB
DATE STARTED 5/19/21 COMPLETED 5/19/21
DEPTH(ft)0.0
2.5
5.0 SAMPLE TYPENUMBERPAGE 1 OF 1
TEST PIT NUMBER TP-1
CLIENT Lucky Seven LLC
PROJECT NUMBER 02293-0001
PROJECT NAME 10991 CR 320
PROJECT LOCATION Rifle, CO
GENERAL BH / TP / WELL 02293-0001 CR 320 RIFLE USDA.GPJ GINT US LAB.GDT 9/23/21Huddleston-Berry Engineering & Testing, LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
GRAPHICLOGMATERIAL DESCRIPTION
1.0
8.0
Loam
Sandy Loam, trace gravel and cobbles, tan, massive, structureless, firm
Bottom of test pit at 8.0 feet.
NOTES
GROUND ELEVATION
LOGGED BY SD
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION dry
AT END OF EXCAVATION dry
AFTER EXCAVATION ---
TEST PIT SIZE
EXCAVATION CONTRACTOR Hi-River GROUND WATER LEVELS:
CHECKED BY MAB
DATE STARTED 5/19/21 COMPLETED 5/19/21
DEPTH(ft)0.0
2.5
5.0
7.5 SAMPLE TYPENUMBERPAGE 1 OF 1
TEST PIT NUMBER TP-2
CLIENT Lucky Seven LLC
PROJECT NUMBER 02293-0001
PROJECT NAME 10991 CR 320
PROJECT LOCATION Rifle, CO
GENERAL BH / TP / WELL 02293-0001 CR 320 RIFLE USDA.GPJ GINT US LAB.GDT 9/23/21Huddleston-Berry Engineering & Testing, LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
GRAPHICLOGMATERIAL DESCRIPTION
1.0
3.0
Loam
Sandy Loam, trace gravel and cobbles, tan, massive, structureless, firm
Bottom of test pit at 3.0 feet.
NOTES
GROUND ELEVATION
LOGGED BY SD
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION dry
AT END OF EXCAVATION dry
AFTER EXCAVATION ---
TEST PIT SIZE
EXCAVATION CONTRACTOR Hi-River GROUND WATER LEVELS:
CHECKED BY MAB
DATE STARTED 5/19/21 COMPLETED 5/19/21
DEPTH(ft)0
1
2
3 SAMPLE TYPENUMBERPAGE 1 OF 1
TEST PIT NUMBER TP-3
CLIENT Lucky Seven LLC
PROJECT NUMBER 02293-0001
PROJECT NAME 10991 CR 320
PROJECT LOCATION Rifle, CO
GENERAL BH / TP / WELL 02293-0001 CR 320 RIFLE USDA.GPJ GINT US LAB.GDT 9/23/21Huddleston-Berry Engineering & Testing, LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
GRAPHICLOGMATERIAL DESCRIPTION
1.0
3.0
Loam
Sandy Loam, trace gravel and cobbles, tan, massive, structureless, firm
Bottom of test pit at 3.0 feet.
NOTES
GROUND ELEVATION
LOGGED BY SD
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION dry
AT END OF EXCAVATION dry
AFTER EXCAVATION ---
TEST PIT SIZE
EXCAVATION CONTRACTOR Hi-River GROUND WATER LEVELS:
CHECKED BY MAB
DATE STARTED 5/19/21 COMPLETED 5/19/21
DEPTH(ft)0
1
2
3 SAMPLE TYPENUMBERPAGE 1 OF 1
TEST PIT NUMBER TP-4
CLIENT Lucky Seven LLC
PROJECT NUMBER 02293-0001
PROJECT NAME 10991 CR 320
PROJECT LOCATION Rifle, CO
GENERAL BH / TP / WELL 02293-0001 CR 320 RIFLE USDA.GPJ GINT US LAB.GDT 9/23/21Huddleston-Berry Engineering & Testing, LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
GRAPHICLOGMATERIAL DESCRIPTION