Loading...
HomeMy WebLinkAboutElectrical Inspection Reportlnspection Report Permit #:861 304 Date lnspected:O1- FEB-1 gPermit HoIder:JAVI ER VICENCIO 7256 COUNTY RD 306 PARACHUTE 81 635 Phone: (970) 366-0980 Fax: Email: VICENCIEO @G MAI L.CO MS¡t e:7256 COUNTY RD 306 Parachute County: Garfieldowner :JAVIER VICENCIO Phone:(970) 366-0980 Status:REJECTED lnspection Type: Rough ln Trim Permit:N Constuction Type: REMODEL Bu¡lding Type: RESI DENTIAL lnspector:Norman Feck 303-869-3 442 Corrections:Service was upgraded and is energized. No inspection on that until this point. At the service: 1) 230.284 Missing mast rr\ rrFrt Frr^r t\ ground rods flush with or below grade. 3) 250.50 Missing ground clamp at incoming metal water p¡pe (Above grade p¡ping is plastic). 4) 250.6484 Bury grounding electrode conductor between rod electrodes. Depth isn't required to be T300.5 compliarìt. 5) 408.7 Close unused breaker openings. 6) 250.9 4A or B lntersystem Bond Terminal bar required. Crawl: 1) 250.684 lnstall a crawl access. Water pipe grounding electrode connection shall remain accessible. 2) 33 4.15C 14, 12, and 10 gauge NM cable may not be run on bottom of joists in crawls or basements. Ok to install runner boards, as discussed , along side the NM cabl¡ng. Comments:1) Walls and ceilings ok 2) Front and back porch outlets have no junction boxes but will have surface mount boxes.