HomeMy WebLinkAboutStructural NotesTALLY HO CONSTRUCTION
145 COUNW RD 225
RtFLE, CO 81650-9400
Jobsite Address:O12O HILLTOP LANE
CARBONDALE, CO 81623
ùate:6/21/2L
Sentinel Building Systems Job lD: 841190
Dear Sir:
This letter is to certify that a 35'wide, 50' long 18'front eave height and 15.08' back eave height single slope building as
referenced above and manufactured by Sentinel Building Systems of Albion, Nebraska ís designed in accordance with the
following loads:
Roof Dead Load: 2.5 psf Seismic lmportance Factor: 1.00
Collateral Load: 1.0 psf Seismic Design Category: C
Roof Live Load: 20.0 psf Assumed Site Class: D
R¡gid Frame Live Load: 12.0 psf Seismic Coefficient: 0.518 (Ss*Fa)
Risk Category: ll - Normal
ROOF SNOW LOAD FACTORS Ss=0.34 51=0.08 SDS=0.35 5d1=0.13
Ground Snow Load: 47.62 psf SEISMIC BRACING SYSTEM: Structural Steel System Not
Flat Roof Snow Load: 40.00 psf Specifically Detailed for Seismic Resistance and
Sloped RoofSnow Load (Ps): 40 psf Cantilevered Column System
l=1.00 Ce=1.00 Ct=1.20 Cs=1.00 SEISMIC DATA Cs R
Terra¡n Category: C Interior Frame 0.12 3.00
Roof 0.28 1.25
Wind Load: V: 115 mph Vasd:89.08 mph Left Endwall O.tZ 3.00
Exposure C - Closed Right Endwall O.tz 3.00
lnternal Pressure Coefficient: + 0.18 / -0.18 Front Sidewall 0.28 I.25
Wind lmportance Factor: 1.00 Back Sidewall 0.28 7.25
Longitudinal Base Shear (V): 7.31 (k)
Transverse Base Shear (V): 3.42 (k)
Loads are applied in accordance with the IBC 15 building code. The certifying engineer does not certify that the building code
orloadsspecifiedareadequateorappropriatefortheintendeduseorlocationof thisbuilding. Thebuyerisresponsibleto
verify specified loads are in compliance with the local regulatory author¡t¡es.
Design is in accordance with the applicable sect¡ons of the 2010 ANSI/AISC 360-10 and the 2012 AlSl 5100.
This certification is limited to the steel framework, the metal roof and the metal wall covering, and fasteners required for their
installation. This certification specifically excludes an analysis of the foundation and parts supplied by anyone other than
Sentinel Building Systems.
Sincerely,
s i-J
SENTINEL BUILDI NG SYSTEMS
M. Woebbecke
Certifying Engineer i
frz
4
fj(ì'f
z
,'){]
Tlr
q0a
';.r lii iil'-
237 South 4th Street, PO. Box 348, Albion, NE 68620
TF 800.327.0790 I P 402.395.5076 I F402.395.6369 | sentinelbuildings,com @tl tr @ El oussrowthintl I Rccnowrn.cov