HomeMy WebLinkAboutConditions of PermitcoN DITIONS OF PERMIT
BLRE-09 -21 -7 142
Jason Fitzhugh
Condo Unit 130 - Remodel RePair
1491 3 Hwy 82, Unit 130, Carbondale
Ranch at Roaring Fork Condos, Bldg 1 1, Unit A
Work scope on application form states: "no structural changes,
asbestos mitigation by ceiling removal and recessed lights,
improvements to kitchen/bathrooms. No exterior / shared or
load bearing"
1 ) ALL WORK SHALL COMply W|TH THE 201 5 TNTERNATIONAL BUILDING CODE
(t.R.c,)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l,E,C.C,)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS", NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC
BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERTIFICATE OF OCCUPANCY.
4) IF STRUCTURAL MEMBERS ARE ENCOUNTERED DURING DEMOLITION, SHALL
OBTAIN COLORADO LICENSED PROFESSIONAL ENGINEERS FRAMING LETTER OR
DETAILS AND REMIT DURING FRAMING INSPECTION. SUPPLY ENGINEERS
STAMPED DOCUMENTS FOR REVIEW BY THE BUILDING INSPECTOR AT FRAMING
INSPECTION,
5) GENERAL CONTRACTOR TO VERIFY EXISTING BUILDING CONSTRUCTION ryPE.
SHALL MAINTAIN MEMBRANE PENETRATION PROTECTION IN ALL FIRE-RESISTIVE
ASSEMBLIES, SEE 2015 INTERNATIONAL BUILDING CODE, CHAPTERS 6 &7,
SECTION 714 PENETRATIONS, BE CAREFUL TO ENSURE ANY EXPOSED / EXISTING