HomeMy WebLinkAboutPipeline CalculationsYAERUS,\¡føf.7 <51-l
143 Diamond Avenue
Parachute, CO 81635
1601 Riverfront Dr, Suite 204
Grand Junction, CO 81501
P = Design Pressure (psi)
S = minimum yield strength of pipe (psi)
t = nominal pipe wall thickness (in)
D = outside diameter of pipe (in)
F = design factor
E = longitudinaljoin factor
T = temperature derating factor
in OD
in wallthickness
psi
Class 1, Division 1, Liquid Removal Equipment
Electric Resistance Welded
250F or lower
in OD
in wallthickness
psi
Class 1, Division 1
Electric Resistance Welded
250F or lower
Pipeline Calculations as per ASME 831.8-2018 Gas Transmission and Distribution
Piping Systems for the
G35 Gathering Pipelines
From Section 841 Steel PiPe:
P = (2*S*I/D*F*E*T
Segmentl -GarbonSteel
Three Phase - Buried segment from G35 pad to N23CDP
New 12in .375wall API 5L X52 PSL2 ERW 14-16M|LS FBE OD
TK70 lD with UB Sleeves
þ=
f=
12.75
0.375
52,000
0.50
1.0
1.0
$=
f=
f=
P = (2*S*t)/D*F*E*T
P = 1,529 psi
design pressure (psi)
Segment2-GarbonSteel
Gas Lift - Buried segment from G35 pad to Divide Road ROW
New 4in .237wall API 5L X52 PSL2 ERW 14-16M|LS FBE OD
þ=
[=
$=
f=--
J=
4.5
0.237
52,000
0.80
1.0
1.0
p = (2*S*I)/D*F*E*T design pressure (psi)
P = 4,382 psi
\\klj-solutions.com\dfs\Data\Projects\OilGas\CaerusOilGas\2107-00252_Environmental&Construction Group\2107-00252.10 G35 826 N23 Pipeline Calcs\Calc
Example\Pipe Câlculations Page 1 of 4
Segment3-CarbonSteel
Water Delivery - Surface segment from G35 remote frac pad to F26 lntersection
Used l2in .3751 .281 I .250wall API 5L X52 PSL2 ERW l4-16MlLS FBE OD
þ=
{=
$=
p=
J=
12.75
0.25
52,000
0.50
1.0
1.0
6.625
0.864
65,000
0.80
1.0
1.0
in OD
in wallthickness
psi
Class 1, Division 1, Liquid Removal Equipment
Electric Resistance Welded
250F or lower
in OD
in wallthickness
psi
Class 1, Division I
Electric Resistance Welded
250F or lower
p = (2"S.t/D*F*E*T design pressure (psi)
P = 1,020 psi
Segment4-CarbonSteel
Frac Line - Buried segment from G35 remote frac pad to G35 pad
Used 6in .864wallAPl 5L X65 PSL2 SMLS 14-l6M|LS FBE OD
þ=
[=
$=
t-
p = (2*S.I)/D*F*E*T design pressure (psi)
P = 13,563 psi
826 Gathering Pipelines
Segment5-GarbonSteel
Three Phase - Buried segment from 826 pad to N23CDP
New 12in .375wallAPl 5L X52 PSL2 ERW 14-16MILS FBE OD
TK70 lD with UB Sleeves
þ = 12.75 in OD
{ = 0.375 in wallthickness
$ = 52,000 psi
f = 0.50 Class 1, Division 1, Liquid Removal Equipment
E - 1.0 Electric Resistance Welded
I = 1.0 250F or lower
p = (2.S*t)/D*F*E*T design pressure (psi)
P = 1,529 psi
\\kU-solutions.com\dfs\Data\Projects\OilGas\CaerusOilGas\2107-00252_Environmental&Construction GroupU107-00252.10 G35 826 N23 Pipe¡ine Calcs\Calc
Example\Pipe Calculat¡ons Page 2 ol 4
Segment6-GarbonSteel
Frac Line - Buried segment from F26 remote frac pad to 826 pad
Used 6in .864wallAPl 5L X65 PSL2 SMLS 14-16M|LS FBE OD
þ = 6.625
{ = 0.864
$ = 65,000
P = 0.80
f = 1.0
J= 1.0
in OD
in wallthickness
ps¡
Class 1, Division 1
Electric Resistance Welded
250F or lower
in OD
in wallthickness
psi
Class 1, Division I
Electric Resistance Welded
250F or lower
p = (2*S*I/D*F*E*T design pressure (psi)
P = 13,563 psi
N23 Gathering Pipelines
SegmentT-CarbonSteel
Low Pressure Gas - Buried segment from N23CDP to F26 lntersection
New 1Oin .365wall API 5L X52 PSL2 ERW l4-16MILS FBE OD
p=
l=
$=
p=
l-=
f=
10.75
0.365
52,000
0.80
1.0
1.0
p = (2.S*I/D*F*E*T design pressure (psi)
P = 2,825 psi
SegmentS-CarbonSteel
Medium Pressure Gas - Buried segment from N23CDP to F26 lntersection
New 1Oin .365wallAPl 5L X52 PSL2 ERW 14-16M|LS FBE OD
þ=
l=
$=
p=
J=
10.75
0.365
52,000
0.80
1.0
1.0
in OD
in wallthickness
psi
Class 1, Division 1
Electric Resistance Welded
250F or lower
p = (2*S*t)/D*F*E*T design pressure (psi)
P = 2,825 psi
\\klj-solutions.com\dfs\Data\Projects\OilGas\CaerusoilGas\2107-00252-Environmental&Construction Group\2107-00252.10 G35 826 N23 Pipeline Calcs\Calc
Example\Pipe Calculations Page 3 of 4
Segment9-CarbonSteel
Produced Water - Buried segment from N23CDP to F26 lntersection
New 12in .375wallAPl 5L X52 PSL2 ERW 14-16M|LS FBE OD
TK70 lD with UB Sleeves
þ = 12.75 in OD
[ = 0.375 in wallthickness
S - 52,000 psi
f = 0.50 Class l, Division 1, Liquid Removal Equipment
f = 1.0 Electric Resistance Welded
f = 1.0 250F or lower
p = (2"S.I)/D*F*E"T design pressure (psi)
P = 1,529 psi
Segment 10 - Garbon Steel
Gas Lift - Buried segment from F26 remote frac pad to N23CDP
New 4in .237wall API 5L X52 PSL2 ERW 14-16M|LS FBE OD
þ=
{=
$=
p=
þ=
f=
4.5
0.237
52,000
0.80
1.0
1.0
in OD
in wallthickness
psi
Class l, Division 1
Electric Resistance Welded
250F or lower
p = (!*S.I)/D*F*E*T design pressure (psi)
P = 4,382 psi
\\klj-sotutions.com\dfs\Data\Projects\OilGas\CaerusOilGas\2107-00252 Environmental&Construction Group\2107-00252.10 G35 826 N23 Pipeline Calcs\Calc
Example\Pipe calculations Page 4 of 4