HomeMy WebLinkAboutPlansLevel
SECTION A -Al
—' 9!! zCA✓sr W icl W /}GC&" 7D
,5.V•cX-V7-- arty sdt y~.�;
—4"" aR"ll P/xr 4044 Aa owl
—ftc s WILL, NpT .c/dZP vnAS
Stn/GS !S Ill ?D CC 9:2* K
!V Vt mwIc
Ground Lever
BFL
m \B'a„ .+.+.+..
WINDOW wlN.. EXISTING BASEMENT ART.
SLIDING DOOFS • . . . y . . ' .
12' �"` 8..... . Ground Level.
I AFL 01 p„
1 -8 7 �
La =�EJ I LJ o N sNf
Floor 4
_2 p'
S LARDER ET.�a
AIRS CPM9ER 80a"
BFL
roesD�n � BFLp �
6TRIq' pglLl RAIN DRAIN
round Level _ _01 01, ".W. .". .+.
` . •`"`. .` Ground Level`
. . . . . . . . . . ..`. . •00
FLOOR PLAN
117 Ponderosa Dr Glenwood Springs CO 81601
Wm
`. " . Ground Lew „ ` , " ` + + + +
.0,0„
I II II II
I II Ii II
--------J L-------J
Floor
2. 0"
GroUnd'Level�'
DATE
PLUVIAL SLOPE�
--'_
----
Ground Level.
o0 Lever
" `Ground Level
. . . . . .
TOP PLAN
09/ 10 / 2021
REYNOLDS BASEMENT ACCESS
GENERAL STRUCTURAL NOTES
GENERAL REQUIREMENTS
I. Design Is based on the 2015 edition of the International Residential
Code (I RC).
2.Deslgn Live Loads:
a. Roof (Snow) .................................... 40 P5F
b. Floors ................................................ 40 PSF
b. Wind ............. qO MPH Basic Aind Speed, 3 second gust
3.AII dimensions, elevations and details on structural documents
shall be verified against the architectural documents prior to
construction or fabrication.
4.The contract structural documents and specifications represent
the completed structure. The contractor shall provide all
measures necessary to protect the structure and existing
adjacent structures and utilities.
5.0oordinate ail openings through floors, walls and roofs with
Mechanical and Electrical Contractors. Notify Engineer of any
openings to be cut in structural systems.
FOUNDATIONS
I. Foundation Design is based on 5olls Report #21-7-753
by H-P/Kumar Geotechnical, Inc., dated September 25, 2021.
Maximum design soil bearing capacity: 2500 PSF.
The Contractor shall review the Soils Report and follow all
recommendations therein, Including, but not limited to excavation,
site conditions, drainage, backfill and compaction, slab -on -grade
construction, drainage systems, and site Inspection requirements.
2.All footings are to bear on undisturbed natural bearing materlals
or compacted structural fill. Compactive effort for structural
fill shall be in accordance With the Soils Engineer's
recommendations. Bearing soils (natural and compacted) shall be
Inspected and approved by the Soils Engineer prior to placement
of footings.
3.Avold excessive Netting or drying of the excavation, keeping the
excavation reasonably free of water during placement of
concrete for footings.
4.6eneral Requirements:
a. Foundation walls With backfill on only one Wall face shall have
all supporting framing systems or temporary bracing in place
prior to placing backfill (unless noted otherwise on plan).
b. Backfill on walls with fill on both sides to be compacted in
equal lifts each side of wall.
CONCRETE AND REINFORCING, STEEL
I.AII concrete shall attain 5,000 P51 compressive strength within
28 days.
2.Use Type 1-11 Portland Cement (ASTM 0150) with 4-6%
air entrainment. Concrete aggregate to be normal weight (stone).
3.Perform all cast -In -place concrete work in accordance with
"Specifications for Structural Concrete for Buildings," AGI 301-84,
unless noted otherwise. Provide hot or cold weather protection
per AGI 505 or 506.
4.Reinforcing steel shall conform to A57M A615: #4 and smaller =
Grade 40, #5 and larger = Grade 60.
5.Horizontol reinforcing steel shall be made continuous by lapping
bars a minimum of 52 bars diameters at all splices and providing
corner bars. Fabrication and Installation of reinforcing steel shall
conform to AGI 515.
b.Provide accessories necessary to properly support reinforcing
at the positions shown on the documents.
T.Salcium chloride or admixtures containing more than 0.05%
chloride Ions or thlocyanates are not permitted.
B.Do not place pipes, ducts or chases in structural concrete without
prior approval of the Structural Engineer.
STRUCTURAL WOOD FRAMING
A. DIMENSIONAL LUMBER
I.AII timber construction (light and heavy) shall conform to American
Institute of Timber Construction (AITG) and National Design
Speclficotion (ND5) standards.
2.5tructural framing lumber shall be Hemlock Fir, with the
following minimum grades:
Plates and Studs: #2
Joists and Rafters: #2
3.5eams, Posts and Timbers: Douglas Fir Larch #1
4.AI1 sill plates In contact with concrete or masonry foundation shall
be Foundation tirade Redwood or Pressure Treated Hem -Fir #2
or better, designated for "Above Ground" usage as defined be
the American Wood Preserver's Institute.
B. FASTENERS AND CONNECTORS
I.AII timber nailing and connections shall conform to IRC and AITG.
Reference IRS Table No. R602.3(I): Fastening Schedule.
2.Metal connectors for wood framing are manufactured by the
Simpson Strong-Tle Company, connectors with nails shorter than
common as follows:
8d x I14"; IOld x IV2'; Ibd x 2V2", unless noted otherwise.
3.Alternate connections and fasteners to those listed above, which
have I.G.G. approval, may be used upon approval by the Engineer.
4.Log screw connections, Including lead holes, pilot holes, and screw
Installation, shall conform to ND5.
5.5olts for wood member connections shall be A57M A301 with
minimum 11/2" diameter washer each end, unless noted otherwise.
Do not countersink bolts unless noted otherwise.
1*" SAN cur 1n (SLAB . , #4 HORIZ
SLAB ��� _ SUPPORT BAR
DEPT
H
Xx—x
4" STRUCTURAL WALL
3 �
j' DOWEL REINF
-ter DOWEL AT
E NOT: THE SAW CUTTIN6 SHALL BE DONE WITHIN 24 HOURS TO ADHERE MEMBRANE CONTRACTOR'S
PREVENT UNCONTROLLED CRACKING OF THE SLAB AND WHEN TO FOUNDATION
THE CONCRETE HAS HARDENED SUFFICIENTLY TO PERMIT OPTION' WHERE
GUTTING WITHOUT CHIPPING, 51-ALLIN&, OR TEARING. PROVIDE WIRE TIE- STRUCTURAL DOWEL
TYPICAL SAWCUT JOINT NOTE: STABBING' TTTT 15 NOT IN CONTACT
STRUCTURAL DOWEL5 WITH VERT WALL
DO NOT EXTEND APPLY BOND BREAKER 15 NOT RECOMMENDED REINF, PROVIDE #4
W.W.F. THROUGH /i-{ FULL LENGTH AND DEPTH x Ib" L-8" ® 48" O.G.
JOINT. OF THE JOINT. 6" MIN. -�
� ROUGHEN TO
xx—x- 4" 1/4" AMPLITUDE
�=�0 4"
_ 2" MINIMUM - IO" THK
1- #4 CONT. EA. (SLOPE TO N)i FT6 -
2 N KEY SIDE OF JT.
cor. PROVIDE GONT DRAIN TYP U.N.O.
PER SOILS ENGINEER'S
RECOMMENDATIONS- ; 3" GLR -
TYPICAL CONSTRUCTION JOINT TYP U.N.O. TYP
LOCATE UNDER PARTITION WHEN POSSIBLE
TYPICAL C O N C NOT DIMENSIONED
SLAB ON GRADE DTL' S PROVIDE CONTINUOUS PROVIDE STANDARD'
WATERPROOF MEMBRANE HOOK AS FOLLOWS:
INTERIOR SLA55-0N-GRADE ( 5.0.6.) (POND LINER) #4 - 8"
I. UNLESS NOTED OTHERWISE, INTERIORS 5.0.&15 SHALL BE 4" THICK #5 - 10"
CONCRETE SLABS PLACED ON A MINIMUM 4" THICK LAYER OF #65 - 12"
FREE -DRAINING GRAVEL.
2. ALL 5.0.6.'S SHALL BE REINFORCED WITH 6x6- KlAxAIA
WELDED WIRE FABRIC UNLESS NOTED OTHERWISE. OPTION: REPLACE TYPICAL CONCRETE �OUNDATI ON DTL
MESH WITH SYNTHETIC FIBER ADDITIVE PER MANUFACTURERS /t
RECOMMENDATIONS AND ENGINEER'S APPROVAL. PROVIDE IS POUNDSR J
OF COLLATED, FIBRILLATED POLYPROPYLENE FIBERS PER GUBIG
YARD OF CONCRETE, MINIMUM.
3. PROVIDE SLAB CONTROL JOINTS MAXIMUM I5EACH WAY, UNLESS
NOTED OTHERWISE ( SEE TYPICAL DETAILS).
4. PROVIDE FREE -DRAINING &RAVELS AND COMPACTED FILL (WHERE
NECESSARY) ACGORDIN6 TO SOILS ENGINEER'5 RECOMMENDATIONS.
S. GOMPACTIVE EFFORT FOR GRAVELS, STRUCTURAL FILL AND EXISTING EXI5T GONG WALL �\ �T PROVIDE 4" THICK
5UB&RADES WHICH SUPPORT 5.0.6.'5 SHALL BE IN ACCORDANCE WITH 5AII 8 v CONCRETE SLAB -ON -
SOILS ENGINEER'S RECOMMENDATIONS. REMOVED & OP6 I
GRADE- COMPACT 5U5-
6RADE IN ACCORDANCE
BASEMENT 1 A/ SOILS ENGINEER'S
5.0.6. 1 I RECOMMENDATIONS
xxxx—x
fi�"iit 1
�i 2" THICK RIGID
EXIST INSULATION -
FTG EXTRUDED
POLYSTYRENE -
5EE PLAN FOR EXTENT
RAILING -SEE
I I ARCHITECT
SEE PLAN
O.G.
- HORIZ (6R. 60)
#5 a 16" O.G.
EXTERIOR 5.0.G. 4 I VERT (11 60)
(A5 SHOW, I -#5 VERT. ® I6 O.G.
EXTERIOR GRADE
(PLANTER) ® 0.I/5I
DAL #5 x 10" 55" 4"
x-x-x-x
® 12" O.G. (G6 R. 0) EXTERIO
5.0.6. R
#5 @ 16" O.G. HORIZ
�` LI/2" GLR
- ROU6HEN GOLD _T. x x— 12" GLR
TO 1/4" AMPLITUDE-TYP
Dyl #5 x 10"sisal
ROUGHEN GOLD JT
• — - - � �� TO I/4" AMPLITUDE-TYP SEE PLAN
(3)-#5 CONT. BOT p
11.411i
4S:l I:- ,�" #5 ® I6" O.G. 3 GLR 3-#5 CONT.
m SEE PLAN #5 ® 16" O.G.
- -
3'-4" FT6 _
5/4II - I. -Oil I 5/4" 1'-0"
KURTZ I
ASSOCIATES,
INC.
5012 GOUNTY RD. 154
GLENWOOD SPRINGS,
GOLORADO
(Q-70) 145-6305
REYNOLDS
ADDITION
111 PONDER05A DR.
SLENWOOD SPRINGS,
COLORADO
DRAWN BY: M.C.E.K.
CHECKED BY: B.J.K.
SCALE: A5 SHOWN
PROJEGT #: 21—IS
DATE:
GON5TRUGTION 5ET:
10/05/2021
SHEET TITLE:
GENERAL NOTES
4 DETAILS
SHEET:
HEADER 5GHEDULE
NEW OP6'S @ EXISTING
NORTH WALL
5AW-GUT
HEADERHEADER
SUPPORT
OP6
PO5T5
(3)-1.3/4" x
(2)-2xb TREATED
5.1/2" LVL
JACK P05T5
(5)-1.3/4" x
(2)-2xb TREATED
'.1/4" LVL
JACK P05T5
NOTES:
I. Provide temporary shoring for floor $
roof framing adjacent to north wolf.
2. Attach headers to posts w/ AGE-b
post cap each side.
3. Attach posts to face of concrete w/
q/64" dia. powder driven nails a 12" O.G..
EXTERIOR SURFACE
5EE ARCHITECT
4"
DWL $
REINF - 5E
T.O. FT6
SEE PLAN TYP
■
all
IMI 11
TYP I GAL GONGRETE 57A I R
I" = 1'-O"
R�7
#3 x TIE ® 24" O.G.
IN/ (2)- #4 TOP $ 50T
#4 ® 1'-4"
EXIST. FT6--\
EXIST. BA5EMENT 5.0.6.
i T.O. SLAB = -V-1"
SEE ARCHITECT T.O. 5LA5 =
FOR EXACT OP6
LOCATIONS
5AW40UT OP6 5AW G—UT OP6 T.O. SLAB = 5AN-OUT OP6
"1 ,
WINDOW SILL — — ���
TA = -6-10" TA = -4'-0" SEE DWL
NOTE NO. 12
B
Tyj
SEE
ARCHITECT
X — X —
DIAL #4
32"L,
GLR
WALL
SEE PLAN
;11
DWL #4 x
E1
#5 ® I6" O.G.
HORIZ $ VERT
(2)-#5
CONT.
TH=
-q'-2.
T.O. 5LAB
C C
b"
a"
26'-4"
DWL NCW WALL TO EXI5TIN6
yy/ (1)-*0 x 24" TOP $ BOTTOM.
DRILL D/4" old. x 5" HOLE IN EXI5TINS
GONG, GLEAN HOLES $ ATTACH DWL W/
2-PART STRUCTURAL EPDXY,
TYP 2 PLACES
SLOPE
SLAB TO
DRAIN -
\,
TYP
10
1\Lla.,
EXTERIOR
5.0.6.
_n
I
5I TW = I
C
FOUNDATION FLAN
1 /4"=1'-O"
NOTE NO. 11
am
PLAN
NORTH
G� r
T.O. 5LAB =
N
m
PROVIDE HORIZONTAL
CORNER BARS TO MATCH
HORIZONTAL WALL REINF-
TYPICAL
(5EE GENERAL NOTES)
TF =-II'-2" -
TYPICAL
ALL AROUND
TA =-O'-II"
TYPICAL
UNLE55 NOTED
FOUNDATION PLAN NOTES:
I. Concrete foundation walls to be 8" thick unless noted otherwise (U.N.O.)
2. Dimensions this sheet are to face of concrete U.N.O.
3. TIN = top of concrete wall.
4. TF = top of concrete footing.
5. t denotes step in top of wall
b. Footings are to bear on undisturbed natural bearing soils or compacted
structural fill.
-f. Finish grades are to provide 56" minimum cover for exterior footings.
5. designates existing 5" concrete basement wall.
a. designates 2" thick rigid Insulation (Extruded polystyrene).
10. Datum: 0'-0" = T.O. Plywood, existing main level floor.
II. Reinf wall $ ftg per lower wall A/52.
12. Intermediate bearing wall® stair. Relnf wall $ ftg, and provide dowel to
stair per lower wall A/52.
KURTZ
ASSOC, I PATES
INC..
5012 COUNTY RD. 154
6LENW00D SPRINGS;
COLORADO
(a70) C145-6305
REYNOL]�S
ADIDITION
II-f PONDEROSA DR.
6LENWOOD SPRINGS,
00LORADO
DRAWN BY: M.C.E.K.
CHECKED BY: B.J.K.
SCALE: AS SHOWN
PROJECT #: 21-I5
FmMPI
CONSTRUCTION SET:
10/OS/2021
SHEET TITLE:
GENERAL NOTES
4 DETAILS
SHEET:
5 2