HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 491 High Aspen Dr, Glenwood Springs, CO 81601 Parcel No.: _218736104031
Owner Name: High Aspen Ranch HOA Owner Phone: (970) 319-8297
Designed By: Odisea Engineering Designer Phone: (970) 527-9540
Contractor: Form 4:4 Contractor Phone: (970) 379-0643
Minimum Tank Capacity: 3,500-gallon Minimum Absorption: 4,938 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7074_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _10/14/2021____________________ Expiration Date_10/14/2022_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by Odisea Civil and Structural Engineering dated October 13, 2021. Changes to the design
and permit must be approved by Garfield County Public Health and the designer prior to
construction.
The new OWTS will serve a new private clubhouse. The system will utilize the existing OWTS that
served the historic clubhouse, which consisted of a 1,000-gallon septic tank and a 2,540 ft2 gravel
bed. The new OWTS components will consist of a new, single-compartment 2,500-gallon septic tank
set level with access to grade and an effluent filter installed in the outlet tee of the tank. Effluent will
gravity flow to the existing tank, then to two new distribution boxes set level with access to grade
that will distribute effluent to the existing 2,540 ft2 of existing STA and 2,400 ft2 of new STA (4,940 ft2
total STA). The new STA will consist of two four-row gravelless chamber beds, each row consisting of
25 Infiltrator Quick4 chambers per trench (100 chambers total). Inspection ports will be installed at
each corner of each bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
10/14/2021
Issued By: Garfield County Environmental Health
Department
Date