HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 565 Faranhyll Ranch Rd, Glenwood Springs, CO 81623 Parcel No.: _239510300133
Owner Name: Jenn Dockery and Tony DeMoraes Owner Phone: (970) 355-4811
Designed By: CTL/Thompson, Inc. Designer Phone: (970) 945-2809
Contractor: Osage Inc. Contractor Phone: (970) 309-8234
Number of Bedrooms: 5 Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 1,120 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7159_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _10/15/2021____________________ Expiration Date_10/15/2022_________________5
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CTL/Thompson, Inc. submitted via email on October 11, 2021. Changes to the design
and permit must be approved by Garfield County Public Health and the designer prior to
construction. The new OWTS will serve a new 5-bedroom residence. The system will consist of a
new, two-compartment minimum 1,500-gallon septic tank set level with access to grade and an
effluent filter in the outlet tee of the tank followed by a 400-gallon pump chamber with a pump in
the tank (both low-head and high-head pumps are presented as options). Effluent will be pressure-
dosed to an automatic distributing valve at the high-point of the system set level with access to
grade that will distribute effluent to 1,140 ft2 of STA. The new STA will consist of five gravelless
chamber trenches. Each trench will consist 19 Quick4 chambers per trench (95 chambers total). The
pump line and distribution laterals are to be constructed of 1.5-inch diamneter Schedule 40 PVC with
3/16-inch orifices every 4-feet on-center. Orifices are to face upward, except for every fifth orifice,
which will face down to facilitate drainage. Laterals will be hung from the underside of the
chambers. Inspection ports are to be installed at the distal end of each trench. Maintain all setbacks
and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
10/15/2021
Issued By: Garfield County Environmental Health
Department
Date