HomeMy WebLinkAboutSubsoil Study,RECEIVED
h¡o\/ T 0 20?t
GARFIELÞ OOUNTY
COMM U iJ ITY D EVELOPñ/iË ÑT
Huddleston-Berry
Engineering & Testing, LLC
2789 Riverside Parkway
Crrand Junction, Colorado 81501
Phone: 970-255-8005
Info@huddlestonberry. com
October 15,2021
Project#02332-0002
Stricklan Homes, LLC
PO Box 1749
Rifle, Colorado 81650
Attention: Ms. Kortnie Stricklan
Subject:Geotechnical Investigation
62 Meadow Creek Court
Parachute, Colorado
Dear Ms. Stricklan,
This letter presents the results of a geotechnical investigation conducted by Huddleston-Berry
Engineering & Testing, LLC (HBET) for 62 Meadow Creek Court in Parachute, Colorado. The
site location is shown on Figure 1 - Site Location Map. The proposed construction is anticipated
to consist of a single-family residence. The scope of our investigation included evaluating the
subsurface conditions at the site to aid in developing foundation recommendations for the
proposed construction.
Site Conditions
At the time of the investigation, the site was open with slight to moderate slopes down to the
north. Vegetation consisted primarily of weeds and brush. The site was bordered to the north by
Meadow Creek Court, to the south by a golf course, to the west by an existing residence, and to
the east by a vacant lot.
Subsurface f nvestisation
The subsurface investigation included two test pits at the site as shown on Figure 2 - Site Plan.
The test pits were excavated to a depth of 10.0 feet below the existing ground surface. Typed
test pit logs are included in Appendix A.
As indicated on the logs, the subsurface conditions at the site were consistent. The test pits
encountered 1.0 foot of topsoil above brown, dry to moist, stiff to very stiff silt soils to the
bottoms of the excavations. Groundwater was not encountered in the subsurface at the time of
the investigation.
Laboratorv Testine
Laboratory testing was conducted on samples of the native soils collected from the test pits. The
testing included grain-size analysis, Atterberg limits determination, natural moisture content
determination, and maximum dry density and optimum moisture content (Proctor) determination.
The laboratory testing results are included in Appendix B.
62 Meadow Creek
#02332-0002
t0/tst2t
Hud¡lltxton Bery
Ëqìrdhs e Tcrint. LLC
The laboratory testing results indicate that the native silt soils are slightþ plastic. In general,
based on our experience with similar soils in the vicinity of the subject siteo the native silt soils
are anticipated to be slightly collapsible.
Foundation Recommendatio+s
Based upon the results of the subsurface investigation and nature of the proposed construction,
shallow foundations are generally recommended. Spread footings and monolithic (turndown)
structural slab foundations are both appropriate alternatives. However, as discussed previously,
the native soils are moisture sensitive. Therefore, in order to provide a uniform bearing stratum
and reduce the risk of excessive differential movements, it is recommended that the foundations
be constructed above a minimum of 24-inches of structural fill.
The native silt soils, exclusive of topsoil, are suitable for reuse as structural frll. Imported
structural fill should consist of a granular, non-expansive, non-free draínins, material approved
by HBET.
For spread footing foundations, the footing areas may be trenched. However, for monolithic slab
foundations, the structural fill should extend across the entire building pad area to a depth of 24-
inches below the turndown edges. Structural fi1l should extend laterally beyond the edges of the
foundations a distance equal to the thickness of structural fill for both foundation types.
Prior to placement of structural fill, it is recommended that the bottom of the foundation
excavation be scarified to a depth of 6 to 8 inches, moisture conditioned, and compacted to a
minimum of 95% of the standard Proctor maximum dry density, within +2Yo of the optimum
moisture content as determined in accordance with ASTM D698. Structural fill should be
moisture conditioned, placed in maximum 8-inch loose lifts, and compacted to a minimum of
95Yo of the standard Proctor maximum dry density for fine grained soils and 90% of the modified
Proctor maximum dry density for coarse grained soils, within t2o/o of the optimum moisture
content as determined in accordance with ASTM D698 and D1557, respectively.
Structural fiIl should be extended to within O.l-feet of the bottom of the foundation. No more
than 0.l-feet of gravel should be placed below the footings or turndown edge as a leveling
course.
In order for HBET to ßsue a subsrøde, øpproval letter for Gørlield Countv. øn ooen-hole
inspectíon wíll be reøuired: ìncludíne proofrollíns and comoøctìon testínE. deoendíne uoon
the suberade materiøL. In, ødÚìtion, ít will be necessøm for HBET to test comoactìon of the
structurøl lill at everv l2-inch v?ltícøl interval.
For structural fill consisting of the native soils or imported granular materials, and foundation
building pad preparation as recommended, a maximum allowable bearing capacity of 1,500 psf
may be used. In addition, a modulus of subgrade reaction of 150 pci may be used for structural
fill consisting of the native soils and a modulus of 200 pci may be used for suitable imported
structural fill. Foundations subject to frost should be at least 36-inches below the finished grade.
Water soluble sulfates are common to the soils in Western Colorado. Therefore, at a minimum,
Type I-II sulfate resistant cement is recommended for construction at this site.
2Z;\20fi8
^I
I.I¡ROIÊCT,5\02112 - Str irtl l¡n HoÌrrìs\02 ì ì2-llll02 ti? Mc¡dow Crmk Ct\?fxl - C*o\0211?-lXl0? LR i0l5? I ¡lo¡
62 Meadow Creek
#02332-0002
t0n5t2t úr8:n&ring& Tëring,
Any stemwalls or retaining walls should be designed to resist lateral earth pressures. For backfill
consisting of the native soils or imported granular, non-free draining, non-expansive material, we
recommend that the walls be designed for an equivalent active fluid unit weight of 45 pcf in
areas where no surcharge loads are present. An at-rest equivalent fluid unit weight of 65 pcf is
recommended for braced walls. Lateral earth pressures should be increased as necessary to
reflect any surcharge loading behind the walls.
Non-Structural F loot S,lab a,nd Exterior f,'latwork Recommendations
In order to limit the potential for excessive differential movements of slabs-on-grade it is
recommended that non-structural floating floor slabs be constructed above a minimum of 18-
inches of structural fill with subgrade preparation and fill placement in accordance with the
Foundation Recommendations section of this report. It is recommended that exterior flatwork be
constructed above a minimum of l2-inches of structural fill.
Drainaee Recommendations
Gradins ønd drøinase øre crít¡cal to the lons-term oerformance of the strugture. Grading
around the structure should be designed to carry precipitation and runoff away from the
structure. It is recommended that the finished ground surface drop at least twelve inches within
the first ten feet away from the structure. It is also recommended that landscaping within five
feet of the structure include primarily desert plants with low water requirements. In addition, it
is recommended that automatic irrigation, including drip lines, within ten feet of foundations be
minimized.
HBET recommends that stnface downspout extensions be used which discharge a minimum of
15 feet from the structure or beyond the backfill zone, whichever is greater. However, if
subsurface downspout drains are utilized, they should be carefully constructed of solid-wall PVC
and should daylight a minimum of 15 feet from the structure. In addition, an impermeable
membrane is recommended below subsurface downspout drains. Dry wells should not be used.
As discussed previously, shallow groundwater was not encountered at the time of the
investigation. However, a perimeter foundation drain is recommended. In general, the perimeter
foundation drain should consist of prefabricated drain materials or a perfiorated pipe and gravel
system with the flowline of the drain at the bottom of the foundation (at the highest point). The
prefabricated drain materials or gravel should extend along basement walls to within 36-inches
of the finished grade. The perimeter drain should slope at a minimum of 1.0% to daylight or to a
sump with pump. The drain should also include an impermeable membrane at the base to limit
the potential for moisture to infiltrate vertically down below the foundations.
General Notes
The recommendations included above are based upon the results of the subsurface investigation
and on our local experience. These conclusions and recommendations are valid only for the
propo sed construction.
òJZ:U008 ALL PROÍICTS\o2332 " Stri0klän llonca\02332'0002 ó2 Mcrdow Cruck CM00 - Oro\02332-0002 LRl0152l.doc
62 Meadow Creek
#02332-0002
t0/t5/21 @ Iluddleston Berry
E¡tùr*lìg & T.slúg' LI-c
As discussed previously, the subsurface conditions encountered in the test pits were consistent.
However, the precise nature and extent of any subsurface variability may not become evident
until construction. As a result, it is recofirmended that HBET provide construction materials
testing and engineering oversight during the entire construction process. In addition, the
homeowner and any contractors working on the project should be made aware of the risks
associated with moisture sensitive soils.
It is ímoort(nt to notp that the recommendatìons herein øre intende( to reduce the risk of
structurøl movement ønd/or dømøgq to varvins deprees, øssocíated w¡th volume chønge of the
natíve soils. Howeven HBET cønnot predict lpne-tqlm chanws ín subsurføce moìsture
condítíons ønd/or the oreclse møsnítude or extent of volume chønse ín the natíve soils. ll/here
sÍgnífîcant ìncreases in subsurface moßture occur due to ooor grødíng, ímorpoer stormwøter
mnnosgment. utìlitv líne failure. excess irrísation, or other cause. eíther duríns co,nstruction
ol the resuV of actìons of the prooertv owner, sçveral ìnches of movement arq possìble. þ
adÚitíon. gryt.føilure to comolv wíth the recommendatíons in thß report releases Huddleston-
Berrv Ensíneerîns & Testine. LLC of anv lìabílítu.n'íth reeørd to the structure performance.
'We are pleased to be of service to your project. Please contact us if you have any questions or
comments regarding the contents of this report.
Respectfu lly Submitted:
Huddleston-Berry Engineering and Testing, LLC
Michael A. Berry, P.E.
Vice President of Engineering
42:\2008 ALLPROJËCTS\02332 - Stricklm Homes\02332{002 ó2 M@dow Cræk CtU00 - Geo\02332{oû2 LRlol52l.doc
FIGURES
z(
I
,\
'|
\.j.
APPENDIX A
Typed Test Pit Logs
GEOTECH BH COLUMNSUS LAB.GDT 1CY15/21:0aemo-{z3Emuol\,o)o)l\)oooN)ot-mz{(t()ãotIo3(DØ\O ^ lQ iÌ{\¡ff\¡äoô¡ cÊi<-r-5 ÞFiXPæF? c- 2'!1ıo:J rD Oeg; ?iíã'trFôFCvf!1ræ^.<0ÞüE F'oÞö!.ocFrlgqf.|-o!noLmÕ{ooIoz!qtıC)o¿)o!1Pm(){zÞ=mo,N)=oqto.o€oãxooÊ={mv,{!+zc=trmn-{På.It6)mo'11zo{m(t,t-oootnc,E(Dmx()oz3mEoo-.{ıC)-(DtC)xImxC){ozooz{¡c){o7o0'c,Þmtt,vmo(ol\)ñC)4ml)xmc,E@oo3!|-m{mI(oNñttmÐmxo-{ızamzE,oïmxoD-{ızèeoo7Voo>2=-looismñtEotrÈxEeËtrttþtOIzlIâtel{mCD{!{LNmPoDEPTH(fr)GRAPHICLOG+mÐtrom(toÃtJozSAMPLE TYPENUMBERRECOVERY %(ROD)BLOWCOUNTS(N VALUE)POCKET PEN.(tsDDRY UNITWT(pcr)MOISTURECoNTENT (%)J-J=B-¡ tDøimn6)FINES CONTENT(Y.\LIQUIDLIMITPLASTICLIMIÏPLASTICITYINDEX.L'. t:.. -!rt.f'.i;-'.'.l.iLIÉ.foðo¡ı'Ø+oÌ,ØIt-*F-0)(tagt@9..(Dô-6)(!at-{=t-voıäqo39.ao;o(D€.Aã(s-g(¡,N\¡NN(¡(oo@oo3ooøE.o,9o(¡ô
BH COLUMNS 023324002 62 MEADOW CREEK CT.GPJ GINT US LAB.GDT!vomo{zc=Emuot\)(¡)(¡)l\)ooo'\)c)rmz{CN=.c)ãoTo3o@\o^l!|ar-¡ry{äÕÞ ooã.r-5 Þ='{X3¡F!¡ ã :'!1do= ô oqc a ?ıF ÈryôFCv rs. u,æ<oaÈ.¡i Ë'3-ã3.üqR"Èìo'?sqr--l)!vgm()oo-{ız!n,q,Ico;,o!7emozÞ=m(t)N)(D0,o.oÉoıo-oocã{rfla{!{zc=_@#mRV--{qP.À)zomv,-ooomcl{D@mxC){oz=mdToE'-{ôc,FTD0to-ImxC){ozooz{vÕ-{o7ait'fg{mU,-{7tmtrt(oN)No¡mc)xmoTD@oo3!rnrmct(oÀ)?\).tt-{m7mxoÞÞ{ızII{mzE,o.rlmxoızo.?ono>E-roËFm{^míÐËËlhızo.2o1ozImrm=o2mU,{!{(t,ñmIoDEPTH(fr)GRAPHICLOG3+mnt-omCNon1t-{ızSAMPLE TYPENUMBERRECOVERY %(ROD)BLOWCOUNTS(N VALUE)POCKET PEN.(tsÐDRY UNITWT(pc0MOISTURECoNTENT (%)¿- -'l=äuimxoFINES CONTENT(Y,)LIQUIDLIMITPLASTICLIMITPLASTICITYINDEX"..r-. rs..i.,,'. .r.i. ¡"- .'.r..;. t¿¿ t\ . .tzjLTÉ.o(oll¡=ô6-{ol,Øo.t-otooqt@Ø¡t'o_c)fDar-+t-vgc'é=;-?o3o.Øf+ano(De6sË-.EàN(¡Nc¡,N(o(fIDoo3c}rìØıotIo(îô
APPENDIX B
Laboratory Testing Results
Huddleston-Berry Engineering & Testing LLC
2789 Rive¡side Parkway
Grand Junction, CO 81501
970-255-8005
GRAIN SIZE DISTRIBUTION
CLIENT Slricklan Homes PROJÊCT NAME 62 Meador Creek Court
PROJECT NUMBER 02332-OOO2 PRO.|ÊCT LOCAT¡ON Parachute. CO
U.S. SIEVE OPENING IN INCHES I U.S. SIEVE NUMBERS I HYDROMETER
20 40 50 60 100
t-Tg
g
t¡
É.
IJJz
lL
Fz
1Ilo
É.
u.tÈ
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
100 10 1
GRAIN SIZE IN MILLIMETERS
0.1 0.0'l 0.001
I I 'tT {
COBBLES GRAVEL SAND SILT OR CLAY
coârse fine coarse medium fine
Specimen ldentification Classification LL PL PI Cc Cu
o TP-l GBI 9t21 SILT(ML)27 22 5
a TP-2, GBI gt2t srLr(ML)25 23 2
Specimen ldentification D100 D60 D30 D10 %Gravel %Sand %siÍt %Clay
o TP-{, GBf 9t21 9.5 0.0 9.6 90.4
ñ TP-2, GBt gt21 9.5 0.0 r0.0 90.0
Huddleston-Berry Engineering & Testing, LLC ATTERBERG LIMITS' RESULTS
Riverside Parkway
Junction, CO 81501
970-255-8005
CLIENT Stricklan Homes PROJECT ìIAME 62 Meado¡v Creek Court
PROJECT NUMBER 02332.0002 PROJECT LOCATION Parachute, CO
P
L
A
s
T
I
c
I
T
Y
I
N
D
E
X
2
1
CL-ML @ @
0 E
0 2A 40 1
LIQUID LIMIT
Specimen ldentification LL PL PI #200 Classification
a TP-1, GBl 9t2112021 27 22 5 90 srLT(ML)
a TP-2, GBl 9t21t2021 25 23 2 90 s¡LT(ML)
Ioô
t¡J
N@
NôçNo
No
ØF
E
Jo
uo
É.u
F
3oo
Uã
N@
NôôIN
Nô
zo
ts
ô-Eo(.)
Huddleston-Berry Engineering & Testing LLC
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
MOISTURE.DENSITY RETATIONSHI P
PROJECT NAME 62 MeadowCreek Court
PRO.JECT LOCATION Parachute, COPROJECT NUMBER 02332.0002
CLIENT Stricklan Homes
r0l
\
\
\
\
\
\
'I
\
\
\
\
\
\
\
\
\
\
\
\
/\\/\
./\\/\
Sample Date:
Sample No.:
Source of Material:
Description of Material
9t2112021
GBI
14s TP-I
SILT(ML}
Test Method ASTM D698A
140
135 TEST RESULTS
Maximum Dry Density 108.0 PCF
Optimum Water Content 15.5 o/o
130
125
GRADATTON RESULTS (% PASSTNG)
#200 #4 3t4"
90 100 100
(Jo.tÞ
ïnz
uJo
É.o
ATTERBERG LIII'IITS
1 20
LL PL PI
27 22 5
11s Curves of 100% Saturation
for Specific Gravity Equalto:
110
2-80
2.70
2.60
105
100
95
90
5 15010
WATER CONTENT o/o
20 25 30