HomeMy WebLinkAboutPermit Card - Original
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 1708 CR 121, Carbondale, CO 81623 Parcel No.: _218932200033
Owner Name: SGJD, LLC Owner Phone: (303) 495-4837
Designed By: SGM, Inc. Designer Phone: (970) 945-1004
Contractor: Harriman Construction, Inc. Contractor Phone: (970) 927-1161
Number of Bedrooms: 4 Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 808 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7124______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _11/12/2021____________________ Expiration Date_11/12/2022_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by SGM, Inc. dated November 9, 2021. Changes to the design and permit must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new 4-bedroom residence. The system will consist of a new, two-
compartment minimum 1,250-gallon septic tank set level with access to grade with a pump in the
second chamber of the tank. Effluent will be pressure-dosed to an automatic distributing valve set
level with access to grade that at the high-point of the system to distribute effluent to 816 ft 2 of STA.
The new STA will consist of one 12 feet wide by 68 feet long 2-feet deep unlined sand filter
constructed with secondary sand media. The sand filter will have four distribution laterals with 1/8-
inch diameter orifices facing up, with every fifth orifice facing down to allow drainage, every 4-feet
on-center along the laterals. All orifices shall have orifice shields. The pump line and distribution
laterals shall be constructed of 1.5-inch diameter Schedule 40 PVC. Laterals will end in a sweeping ell
90-degree bend with a flushing valve assembly. Inspection ports are to be installed at each corner of
the bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/12/2021
Issued By: Garfield County Environmental Health
Department
Date