HomeMy WebLinkAboutSubsoil Studyc¡RERE€J(, c-ruJz.É,<
>EFurz=
-CL
8ËoH
I¡J ts
tt-3ll=
óã
GEOLOGIC REVIEW AND SOILS
ENGINEERING REPORT
TRACT44 ANTLERS
ORCHARD DEVELOP]TIENT
SILT, COLORADO
Prepared For:
J CaliberGonstruction
Prepared By
CAPSTOftüE
ENTFRPRNSES WEST, u-c
GEOTECN.{ NNCAL ANÞ il[/l[þ{TNG ENGNIVEER,INIG
TESTTIUG AN¡D ThISPECTION SERVNCES
618 FARTEE DRIVE
GRAND JUNCTIO|{, C0 8150/*
Pr-roN¡E {9V Aj 250-5551
martin@capstonewest"com
June 19,2020
JobNo.4545
CAPSTOruE "'.-:ENTERPRTsFS WESIil Ltc
GEOTECfINTCAL AN¡D MTIStrf{G ENGINEERING
TESTING AI\¡D INSPECTION SER\TICEs
ó¡8 FÂRTEE DRIVE
GFA¡¡D JUNC-rIOÌ¡, CO ðt50&
PHOr.¡E (97O) 25&5551
martin@cãpÉtonenest.@m
JOB #4545
Attention:
June 19, 2020
J Caliber Construction
Rifle, CO
Subject:Foundation Recommendations
TRACT 44 ANTLERS
ORCHARD DEVELOPMENT
SILT, COLORADO
Per your request, Capstone Enterprises West, LLC (Capstone) performed a geotechnical
investigation on the foundation materials your property off of Harvey Gap Road. The purpose of
the work was to determine the nature of the material on site and to make recommendation for the
foundation.
SITE LOCATION
The site is in the southwest quarter of section 36 Township 5 South Range 92 West. The following
maps show the general location.
SITE DESCRIPTION
The property sits on the flank of a resistive sandstone hill as shown in a later Google Earth
isometric image. The site is essentially undisturbed grazing land. The central topographic feature
of this lot is a mild ridge that runs diagonally across the property from the southwest corner to the
northeast corner. The ground slopes off to the northwest, the south west and the southeast at
approximately 5%.
2
Job 4545Capstone EnterPrises Vüest, LLC
raÈ
Iü
t¡t
út
Site
út
s¡llr
+ßiItl
tattat
r:l:J¡ i
GEOLOGIC DESCRIPTION
Bedrock in the area has been mapped as the Sandstone Unit of the Wasatch Formation (Twss).
The USGS su¡face geology map is presented on the following page with the approximate property
line.
3
Job 4545Capstone EnterPrises Westr LLC
EtEt qo.CþJTT 'JseM ses-frdrêfug euofsdeJ'e6eull qye¡¡ e¡6oog oqt uoql ueql 'e6ed ôulrvro¡¡o¡ otlt uo poluosold e¡e s6o¡cl6o¡oe6 oql'uotlcnllsuoc ol.loud sìseqlos eul¡ Á¡.redold eqt qsllqelso ol'u!peÁeruns oq ol poou llt^ outl ÁUedold lenlce oql 'outl ÁUedo¡d elerllxo¡ddeeql pue suo[ecol lld ]so] eqt s6oqs e$eull $ut¡ro¡¡o¡ oql 'ollsqo^5¡g Á¡unoc plollJeÐ orlt ruorl popeolu/r^op seM eul¡ rQledotd eq1 'quefe¡6oog tut popeol olo/r^ soleu¡plooc oql 'SdÐ ploqpueq e 6ulsn ul peÁerunsolo/v\ suotlecol otlt olts otlt te slld lsol ? Jo uollenecxe oqt polcollp ouolsdeCSNOIIVÐIISSAN I f CVIUNSs NSâ.-aIt-qFãÉFãFãæEl; lqÇÇq{-+-4*-iæTãËaÉ-æã-4-ffilq.F-æFæm#.r---s* [î'l-çIF.æ fqlôaryffid&m-*-*fã laææf t_|æræaf ılã;-Çr-[Er-ræ-*f-!lôtrffim*ræ[-WÛæt_.1æIL;JÜ@/{sat¡it
o 0
1
2
3
4
2
3
7
I
I
1A10
-rP"r
TP.3
TEST PIT GEOLOGY
TP-2
Topsoil- Gayey Silt W/ Roots
Mo¡t Silt
Pl=9
o
Topæil- Siltw/ Rocms
Firrn SilS tay
P!=9
Drlt DensttY = 97.8 Pd'
i{o¡sture = 16.2%
Topsoil- Clayey Silt ld/ Roots
Þtoit Silt
PI=9
Top6o¡Þ Silt usl Ro'ots
Þry Fnn SiþClay
EI =v
Gravel in Tar¡ Silt l{atrbt
Dry FirmSilW(lay
BY DamsüY = fm-g Pcf
fi¡ûisfu¡re = 7-34ú
4
5 5
6
7
9
trP-4
0
1
2
I
2
3
4
5
b
v
ð
G
10
4
g
6
'r
ü
I
t0
5
Job 4545
ü
d-d
t
Capstone EnterPrises West, LLC
4-t
I..ABORATORY TESTING
The suitability for foundation material is generally determined by two tests: the
Swell/Consolidation test and the Atterberg Limits test. The Swell/Consolidation test
consists of placing an undisturbed sample of material in a device that applies a load to
the soil. The specimen compacts or "consolidates". After the initial load stabilizes, the
specimen is saturated, and the specimen will either swell or consolidate further. The
results for the native materials are presented on the following page.
The Atterberg Limits Test gives an indication of the mechanical properties of fine-grained
materials. The first part of the test is to determine the Plastic Limit of the material. Then
the Liquid Limit is determined. The difference between the Liquid Limit and the Plastic
Limit is defined as the Plasticity lndex. Swell potential based on the plasticity limit (Pl) is
shown on the following page.
6
Job 4545Capstone Enterprises Vüest' LLC
TP-3 at4 ft CONSOLIDATION TEST REPORT
0.00%
1
-1.OOo/o
-2.OOo/o
-3.OOo/o
z
É.¡-U'
Þ-zl¡lo
É,
¡.r¡fL
4.O0o/o
-5.00%
s.00%
-7.00%
-8.00%
-9.00%
-10.00%
APPLIED PRESSURE - Psf
Job No.4545 T¡act44
t-
DOr0
WA ERAI
\
Job Number
Sample Source
Sample DescriPtion
Natural Dry Density
Natural Moisture Content
Saturated Moisture Content
Job No.4545 'lracl44
TP-3 at 4 fr
Silty Clay
97.8 pcf
16.2o/o
25.60/o
1
Job 4545Capstone EnterPrises Vrlest/ LLC
CONSOLIDATION TEST REFORT
TP-4 at 3.5 fr
0.00%
1
-1.00o/o
-2.OOo/o
-3.00%
z
ÉFo¡-zt¡loÉl¡¡
o-
4.O0olo
-5.00%
4.00o/o
-7.OOo/o
-8_00%
-9.00%
-10.00%
Job No.4545 Tract 44 APPLIED PRESSURE- psf
0)0r0
TERI DW¡
\
\
\\
\
\
\
\
Job Number
Sample Source
Sample Description
Natural Dry Density
Natural Moisture Content
Saturated Moisture Content
Job No.4545 Tracl44
TP4 at 3.5 ft
Silty Clay
105.8 pcf
7.3o/o
17.9o/o
Plasticity lndex (Pl)lnherent Swelling Capacity
0-15 Low
10-35 Medium
20-55 High
35+Very High
(After Seed et al. 1962)
B
Job 4545Capstone EnterPrises Vrlest, LLC
The results presented below indicate there is a low potential for swelling for the silty clay
material.
Material Source Depth Liquid
Limit
Plastic
Limit
Plasticity
lndex
Swell
Potential
Debris Flow Fines TP-1 2-9 ft 28 19 I Low
Debris Flow Fines TP-2 1-3 ft 31 22 I Low
Debris Flow Fines TP.3 1-3 ft 25 18 7 Low
The Atterberg Limits Tests indicate the alluvial material is suitable for structural fill if the
material is not too coarse.
Samples of the Wasatch Sandstone bedrock were also tested to determine how they
would react to excessive water. The following photos are the before and after photos for
the formation sandstone being soaked overnight. There was no deterioration of the rock
only a crack opening up and dust being washed off the rock.
9
Job 4545Capstone Enterprises West, LLC
DESIGN CONSIDERATIONS
As mentioned earlier, Sandstone Unit of the Wasatch Formation is the bedrock unit in this
area. The alluvial and colluvial sediments overlaying the bedrock are suitable for
structural fill when properly compacted. The alluvial material at the site is low plasticity
(Pl's of 7 to 9) this indicates that it is suitable for structural fill provided the any cobble
sized rock (3" or greater) are not included in the fill. lf this cannot be avoided, the
foundation pad should be capped with a layer of fine aggregate'
DESIGN RECOMMENDATIONS
We recommend this residence be constructed on a stemwall footer foundation. The
foundation should rest on a compacted mat made up of the native materials or impofted
aggregate. The mat should þe a minimum of 1 thick; one foot of soil removed and replaced
afterthe subgrade has been moisture conditioned and cqmpacted. A maximum bearing load
10
Job 4545Capstone EnterPrises West' LLC
of 1,250 psf should not be exceeded. A lateral earth pressure of 45 psf per linear foot should
be designed for. The following sketch shows the general requirements for the foundation
pad.
'ORGAINICS TO BE REMOVED ]FRO]M IFOUNDATION |FOOTPRIINT
BACKFILLING
One of the best methods to protect a foundation and fla¡ryork from changes in moisture content is
the backfill around the perimeterwith a low permeabilityfill (clayey) and compacting it al92o/o of the
maximum dry density of the material at above optimum moisture content. The final contours must
slope away from the foundation and flatwork at slope greater than 10 inches in the first 1 0 feet. Runoff
should be directed into a drainage channel that transports the water to designed discharge point for
the lot.
DRAINAGE AND I RRIGATION
Care must be taken to prevent stormwater from getting near the foundation. At this site an
interceptor swale should be built uphill from the residence to divert water away from the structure.
The success of any foundation and concrete flatwork is contingent upon keeping the sub grade
soils at more or less constant moisture content, and by not allowing surface drainage a path to
the subsurface. Positive surface drainage away from the structures must be maintained at all
times. Landscaped areas should be designed and built such that irrigation and other surface
water will be collected and carried away from foundation elements. The final grade of the
foundation's backfill and any overlying concrete slabs or sidewalks should have a positive slope
11
Job 4545
iNativeiBackfill +95þ/D Cornpaction at +/- 2o./o Opt rMC
Subgrade ìMo¡sture Cond itîor¡ed and Co'mpacted
+qqo./ñ Côrnnartion at +l- 29/o nnt lMa
2.0
1
:1 0
Capstone EnterPrises West, LLC
away from the foundation walls on all sides. We recommend a minimum slope of 10" in the first
ten feet; however, the slope can be decreased to 3" in ten feet if the ground sudace adjacent to
the foundation is covered with concrete slabs sidewalks or pavement.
. Utility trenches may allow water to travel some distance and reach the foundation pad if
left on checked. The water, sewer and dry utility trenches to the residence must be
backfilled with a low-permeability (clayey) material to prevent water movement toward the
residence.
. As much as practical, we recommend, landscaping vegetation that is common to semi-
arid climates, with low moisture requirements. A "drip" system of watering could be utilized
to keep water usage low. Drytype landscaping is encouraged.
. Areas close to foundation elements, where snow will drift and accumulate, should be
protected from standing water during periods of snowmelt.
. Landscaped areas should be placed away from the foundation elements, and be designed
to drain surface runoff away from the foundation elements.
o The structure should have a rain gutter system that directs water away from the foundation
elements.
¡ Water from downspouts should be directed away from the foundation in a well compacted
ditch to minimize infiltration. An impermeable liner should be used if the backfill is
permeable.
r The builder and homeowner must always be careful not to route dra¡nage onto a
neighboring lot.
LIMITATIONS
The analysis and recommendations submitted in this report are based test excavations and
laboratory testing peformed by Capstone. The nature and extent of variation may not become
evident until construction. lf variations then appear, it will be necessary to reevaluate the
recommendations in this rePort.
It is recommended that the geotechnical engineer be provided the opportunity for general review of
the final design and specifications in order that earthwork and foundation recommendations may be
properly interpreted and implemented in the design and specifications. lt is also recommended that
the geotechnicalengineer, ora qualified geo-technician under his supervision, be retained to provide
continuous engineering services during construction of the foundation, excavations, and earthwork
phases of the work. This is to observe compliance with the design concepts, specifications, or
L2
Job 4545Capstone EnterPrises Vrlest, LLC
recommendat¡ons and to modify these recommendations in the event that subsurface conditions
differ from those anticiPated.
Any changes from these recommendations must be approved by the engineer in writing.
Unapproved changes become the sole responsibility of that individual or company performing that
work And assume all liability for the changes and their results. This report does not constítute a
warranty either expressed or implied, as no one c€¡n predict the long-tern changes in subsuface
moistçrre conditions resulting from improper grading, excessive irrigation by the home owner or
neighþors or other causes during and after construction.
lf yo u have any questions, or if we may be of further assistance, please do not hesitate to contact
us
Respectfully Submitted:
CAPSTONE ENTERPRISES WEST, LLC
Martin W. Chenoweth, PE
Registered Professional Engineer
MWC
37784
13
Job 4545Capstone EnterPrises lrlest, LLC