Loading...
HomeMy WebLinkAboutPermit Card Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: Tract 44 Antlers Orchard Development, Silt, CO 81652 Parcel No.: _212736300082 Owner Name: Jose and Sadie Gonzalez Owner Phone: (970) 314-0489 Designed By: Capstone Enterprises LLC Designer Phone: (970) 250-3331 Contractor: Jose and Sadie Gonzalez Contractor Phone: (970) 314-0489 Minimum Tank Capacity: 1,750-gallon Minimum Absorption: 1,134 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-7313_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _01/27/2022____________________ Expiration Date 01/27/2023_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Capstone Enterprises LLC dated September 21, 2021. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new 6-bedroom residence. The new OWTS components will consist of a new, two-compartment 1,750-gallon septic tank set level with access to grade and an effluent filter installed in the outlet tee of the tank. Effluent will gravity flow to the tank, then to a distribution box set level with access to grade that will distribute effluent to 1,188 ft 2 of STA. The new STA will consist of one four-row gravelless chamber bed 12 ft wide by 99 ft long, each row consisting of 24 Infiltrator Quick4 chambers (96 chambers total). Distribution laterals are to be hung from the underside of the chambers with zip-ties. The orifices are to be facing downward. Inspection ports will be installed at each corner of each bed. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 01/26/2022 Issued By: Garfield County Environmental Health Department Date