HomeMy WebLinkAboutOWTS New Leach Field DesignGRAPHIC SOIL LOGS N.T.S. TOP SOILS AND NATURAL BACKFILL OVER TRENCHES 18" MIN. COVER 36" MAX. COVER -' I 1-1111111 1'11111 111111 -I I 111 =_-_---- -I I I -I I -I I i -III -III -III -III: I -III -III -III -III -III -I 11= III -I I -I -I I i-1 I I -III -1 I: NATURAL- I II -1I -1I I III III -1 I GROUND -36" TRENCH TRENCH BOTTOM LEVEL AND ROUGHENED TRENCH CROSS SECTION N.T.S. 12" STANDARD QUICK 4 PLUS INFILTRA1i1R AND END CAP x GRAPHIC SCALE \ / / �_ / _�---rt- zo 0 10 zo 40 e z_ / \ IN FEET ) 1 inch = 20 ft. APPROXIMATE i \ I I \ \ \ \ \ EXISTING WELL EXISTING % OM g0 \ \ \\ RE151DENGE 1 \ - J 1 1 A,S TO REMAIN 250 GALLON SEPTIC TANK 1\ \\ STALL EFFLUENT FILTER, IF ABSENT 5 DISCONNECT EXISTING EFFLUENT PIPE w \ ! O,y INSTALL 4"0 PVC LONG RADIUS 45' ELBOW 1\ \ \ \ \ / INSTALL -THREE (3) 4" VC DISTRIBUTION \ \ ` - ✓� \ �\ \� - - LATERALS, ® 2% MIN. AND LONG SWEEP / '< 90' PVC ELBOWS AT ALL BENDS ' \ \ INSTALL 20'x 6" STEEL SLEEVE- \\ AT DRIVEWAY CROSSING TO 3g �p \ \ PROTECT 4" PVC SANITARY 4" p� \ \ \ EXISTING \ \\ \ / I \ INSTALL:s® 29, \ \ \ \ \Ed \ \ \ \ 4"0 PVC LONG RADIUS 45ELBOW 4"0 PVC LONG RADIUS 22� ELBOW- 4"0 LBOW 4"0 PVC CLEAN OUT, RISER, CAP, \ FLUSH WITH SURFACE - -- _ p y 2• \ \ \ \ \ fish \ \ \ EXISTING-- \ �3e Sf0 'YG 1 \ 1 SHED NSTq 0jC T �SS << STgNOq f NT qRf� Sy gs9 R q \ v \ fkCq 8 -WAY DISTRIBUTION BO #DBOXBC 2 P4U S WITH FLOW GR IDS FLUSH WITH EQUALIZERS, PPIT RO-1 gRg44fC TR ^\//\ \\ �\ \ \ \-- efRSq f)CyfS _ 33'f0' MIN.)_ -- Ln 1 \\\�\ \�� \`� - \ \_- \� ` PROFILE r m PIT _ - L INSTALL END CAPS WITH 4"0 PVC INSPECTION PORTS AND CAPS AT \ _ \\/OTH ENDS OF EACH 7,_ \ ` 1 ` \L - CHAMBER ROW, FLUSH OR ABOVE GRADE Lo C_ / FINIS 4" COU 4" SEWER 4" PVC WYE " RISER " 45' SWEEP BEND SEWER CLEAN OUT DETAIL N.T.S. LEGEND PROPERTY BOUNDARY - - - - -5585- - - - - - - EXISTING MAJOR CONTOUR -- -- -- -- -5584- - - -- -- - EXISTING MINOR CONTOUR 558 PROPOSED MAJOR CONTOUR 5584 PROPOSED MINOR CONTOUR -<-<-<- PROPOSED SWALE FLOW LINE �ISWALE PROPOSED SLOPE x L 7 r GRAPHIC SCALE ( IN FEET ) 1 inch = 60 ft. GENERAL NOTES 1. ALL CONSTRU••TION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY PUBLIC HEALTH AGEN YON -SITE WASTEWATER TREATMENT SYSTEM REGULATIONS, EVEN THOUGH ALL .;UCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THIS DRAWING. THE' CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFE>RED TO IN THE ABOVE MENTIONED REGULATIONS. 2. SYSTEM DESI"N FLOW: 3 BEDROOMS • -AWRAGE DAILY FLOW: 450 GAL/DAY TABLE 6-1 PROPOSED SI`pTIC TANK MATERIAL: CONCRETE MINIMUM REQUIRED SEPTIC TANK CAPACITY: 1,000 GALLONS TABLE 9-1 SOIL TYPE: USDA SOIL CLASSIFICATION: SANDY CLAY LOAM TACTILE EVALUATION TREATMENT LEVEL: TO PROPOSED Tt7EATMENT SYSTEM: CHAMBERS IN TRENCH CONFIGURATION METHOD OF t.FFLUENT APPLICATION: GRAVITY LONG TERM ACCEPTANCE RATE (LTAR): 0.35 GAL/DAY/SQ. FT. TABLE 10-1 REQ'D SOIL TREATMENT AREA:A=45Q GPD 1 286 SQ. FT. FORMULA 43.10.0 0.35 GPD/S.F. ' SIZE ADJUSTMENT FACTOR FOR APPLICATION METHOD: 1.0 TABLE 10-2 SIZE ADJUSTMENT FACTOR FOR DISTRIBUTION MEDIA: 0.7 TABLE 10-3 ADJUSTED SOIL TREATMENT AREA: A=2,625 SQ. FT. x 0.7 = 900 SQ. FT. MINIMUM NUMBER OF CHAMBERS: 900 S.F. = 75 CHAMBERS 12 S.F./CHAMBER RECOMMEND INSTALLING 75 STANDARD INFILTRATOR QUICK 4 PLUS CHAMBERS IN 3 PARALI EL TRENCH CONFIGURATION, AS SHOWN. 3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS PRESENT. 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE TANK AND ON THE FIELD. 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 150 FEET ALONG THE EFFLUENT LINE. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS AT OR ABOVE THE FINAL GRADE, 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE PONTIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY. 9. THE CONTRACTOR SHALL VERIFY ALL DEPTHS, SLOPES AND CLEARANCES FROM THE PROPO=SED HOME, WELLS AND STRUCTURES, PRIOR TO CONSTRUCTION. 10. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE COUNTY OFFICIALS. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SEPTIC TANK SHALL HAVE RISES OVER EACH ACCESS MANHOLE AND ALL RISERS SHALL EXTEND TO OR ABOVE FINAL GRADE. 13. THE CONTRACTOR SHALL VERIFY ADEQUATE SEPARATION DISTANCES PRIOR TO CONSTRUCTION, 14. THE APPLICANT OR LICENSED INSTALLER SHALL NOTIFY THE COUNTY AND THE ENGINEER NO LESS THAN TWO BUSINESS DAYS IN ADVANCE TO SCHEDULE A FINAL FIELD INSPECTION OF THE SYSTEM, PRIOR TO BACKFILLING THE SYSTEM. 15. THE APPLICANT OR LICENSED INSTALLER SHALL PROVIDE AN AS -BUILT DRAWING OF THE SYSTEM TO THE COUNTY AND ENGINEER, UPON COMPLETION. 16. PLACE 2" BLUE BOARD INSULATION ABOVE ALL PIPES WHENEVER DEPTH IS LESS THAN FROST DEPTH. 17. ALL SEWER I INES SHALL BE 4 -INCH DIAMETER POLYVINYL CHLORIDE (PVC) SCHEDULE 40, AND SHALL BE INSTALLED WITH MINIMUM SLOPES NO LESS THAN 2X 18. THE EXISTING; TOPOGRAPHIC CONTOURS SHOWN HEREON WERE OBTAINED FROM THE BUREAU OF LAND MANAGEMENT. 19. THE PROPERTY BOUNDARY AND FEATURES SHOWN HEREON WERE OBTAINED FROM THE " ° BY RICHARD L. HOLSAN, DATED 2 13 98. 20. THE EXISTING SEPTIC SYSTEM SHOWN HEREON WAS OBTAINED FROM THE "reRVIFI n eni LAITY RI III nimr. AND SANITATION DEPARTMENT PERMIT. 282 DATED ABSORPTION TRENCH NOTES 1. ABSORPTION TRENCH LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND TRENCH, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. ABSORPTION TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION, 5. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER TRENCH AREA IS PROHIBITED TO MAINTAIN GOOD SOIL STRUCTURE. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 7. CONTRACTOR SHALL INSTALL 4 INCH DIAMETER SCHEDULE 40 PVC INSPECTION PORTS AND CAPS AT BOTH ENDS OF EACH ROW OF CHAMBERS, IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 8. CONTRACTOR SHALL SNAP OFF THE MOLDED SPLASH PLATES LOCATED AT THE BOTTOM OF THE END CAPS, AND INSTALL THE SPLASH PLATES AT THE APPROPRIATE SLOTS BELOW THE INLETS IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 9. CONTRACTOR SHALL ALIGN THE CHAMBER ROWS PARALLEL WITH THE THE CONTOURS OF THE EXISTING TERRAIN. THE CONTRACTOR MAY CURVE THE ALIGNMENT OF THE CHAMBER ROW, AS NECESSARY. IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 10, CONTRACTOR SHALL PROVIDE AND VERIFY A MINIMUM 4 FEET OF DEPTH, OR GREATER FROM THE BOTTOMS OF INSTALLED CHAMBERS TO CONFINING BEDROCK. 11. CONTRACTOR SHALL PROVIDE AND VERIFY A MINIMUM 2.5 FEET OF COVER, OR GREATER FROM THE BOTTOMS OF INSTALLED CHAMBERS TO FINISH GRADE. 12. CONTRACTOR SHALL CONNECT THE 4 INCH DIAMETER PVC THE DISTRIBUTION LATERAL PIPES AT THE MOLDED CIRCULAR BLOCK OUTS. WHICH ARE SITUATED 8 INCHES ABOVE THE BOTTOMS OF THE STANDARD QUICK 4 PLUS CHAMBER END CAPS, IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES 13. DISTRIBUTION BOX, ROTO -FLOW WEIRS, RISERS, AND LID SHALL BE # DBOX 8C A PRECAST CONCRETE BOX ASSEMBLY MANUF. BY VALLEY PRECAST INC. OR, EQUAL VO .• t 0 Tj . GPt 9399 t�'o �•. z/4�fz2 : ,www ��S�OfVAL EQ��.c FOR AND ON BEHALF OF HIGH COUNTRY ENGINEERING, INC. W U Z Z } OO�W o um�0 z L.0 r [_ w 00 (V � ZO(,jZ >.LLLO :Ix 00 z WOo m �Lu ¢ U � - K d 0 N N 0 � r � O N (n w Ed > Y o 0 U 5600 5600 Z LEGEND: w� 5599 5599 O in L0 Z 5598 5598 w ® TOP SOIL }� }- 5597 5597® ww Z v mus USDA SOII: TYPE 3 SANDY CLAY LOAM 4 5596 5596 Z Z0LL WZ- Z W w 5595 PRO -2 5595 p% NOTES: = In EL=55941 5594 j-. Z 1. PROFILE FITS HERE EXCAVATED BY 5594 �W� OWNER DiRING NOVEMBER, 2021. 5593 PRO -1 EL=5592= 5593 2. NO FREE WATER WAS ENCOUNTERED 5592 5592 w IN THE PIIS AT THE TIME OF THE 2 SOILS EVALUATION. 5591 g5g1 I 3. SOIL SAMPLES WERE FIELD EVALUATED 5590 5590 AND CLA':SLFIED BY COUNTRY 5589 F ENGINEERING INC. DURING NOVEMBER, F= 5589 > 2021, BY VISUAL AND TACTILE � 5588 METHODS ESTABLISH BY THE U.S, w 5588 Z, DEPARTMENT OF AGRICULTURE AND 5587 5587 THE NATURAL RESOURCE ¢ CONSERVATION SERVICE. 5586 5586 � m 5585 5585 R a 5584 5584 a 5583 5583 5582 5582 5581 5581 5580 5580 GRAPHIC SOIL LOGS N.T.S. TOP SOILS AND NATURAL BACKFILL OVER TRENCHES 18" MIN. COVER 36" MAX. COVER -' I 1-1111111 1'11111 111111 -I I 111 =_-_---- -I I I -I I -I I i -III -III -III -III: I -III -III -III -III -III -I 11= III -I I -I -I I i-1 I I -III -1 I: NATURAL- I II -1I -1I I III III -1 I GROUND -36" TRENCH TRENCH BOTTOM LEVEL AND ROUGHENED TRENCH CROSS SECTION N.T.S. 12" STANDARD QUICK 4 PLUS INFILTRA1i1R AND END CAP x GRAPHIC SCALE \ / / �_ / _�---rt- zo 0 10 zo 40 e z_ / \ IN FEET ) 1 inch = 20 ft. APPROXIMATE i \ I I \ \ \ \ \ EXISTING WELL EXISTING % OM g0 \ \ \\ RE151DENGE 1 \ - J 1 1 A,S TO REMAIN 250 GALLON SEPTIC TANK 1\ \\ STALL EFFLUENT FILTER, IF ABSENT 5 DISCONNECT EXISTING EFFLUENT PIPE w \ ! O,y INSTALL 4"0 PVC LONG RADIUS 45' ELBOW 1\ \ \ \ \ / INSTALL -THREE (3) 4" VC DISTRIBUTION \ \ ` - ✓� \ �\ \� - - LATERALS, ® 2% MIN. AND LONG SWEEP / '< 90' PVC ELBOWS AT ALL BENDS ' \ \ INSTALL 20'x 6" STEEL SLEEVE- \\ AT DRIVEWAY CROSSING TO 3g �p \ \ PROTECT 4" PVC SANITARY 4" p� \ \ \ EXISTING \ \\ \ / I \ INSTALL:s® 29, \ \ \ \ \Ed \ \ \ \ 4"0 PVC LONG RADIUS 45ELBOW 4"0 PVC LONG RADIUS 22� ELBOW- 4"0 LBOW 4"0 PVC CLEAN OUT, RISER, CAP, \ FLUSH WITH SURFACE - -- _ p y 2• \ \ \ \ \ fish \ \ \ EXISTING-- \ �3e Sf0 'YG 1 \ 1 SHED NSTq 0jC T �SS << STgNOq f NT qRf� Sy gs9 R q \ v \ fkCq 8 -WAY DISTRIBUTION BO #DBOXBC 2 P4U S WITH FLOW GR IDS FLUSH WITH EQUALIZERS, PPIT RO-1 gRg44fC TR ^\//\ \\ �\ \ \ \-- efRSq f)CyfS _ 33'f0' MIN.)_ -- Ln 1 \\\�\ \�� \`� - \ \_- \� ` PROFILE r m PIT _ - L INSTALL END CAPS WITH 4"0 PVC INSPECTION PORTS AND CAPS AT \ _ \\/OTH ENDS OF EACH 7,_ \ ` 1 ` \L - CHAMBER ROW, FLUSH OR ABOVE GRADE Lo C_ / FINIS 4" COU 4" SEWER 4" PVC WYE " RISER " 45' SWEEP BEND SEWER CLEAN OUT DETAIL N.T.S. LEGEND PROPERTY BOUNDARY - - - - -5585- - - - - - - EXISTING MAJOR CONTOUR -- -- -- -- -5584- - - -- -- - EXISTING MINOR CONTOUR 558 PROPOSED MAJOR CONTOUR 5584 PROPOSED MINOR CONTOUR -<-<-<- PROPOSED SWALE FLOW LINE �ISWALE PROPOSED SLOPE x L 7 r GRAPHIC SCALE ( IN FEET ) 1 inch = 60 ft. GENERAL NOTES 1. ALL CONSTRU••TION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY PUBLIC HEALTH AGEN YON -SITE WASTEWATER TREATMENT SYSTEM REGULATIONS, EVEN THOUGH ALL .;UCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THIS DRAWING. THE' CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFE>RED TO IN THE ABOVE MENTIONED REGULATIONS. 2. SYSTEM DESI"N FLOW: 3 BEDROOMS • -AWRAGE DAILY FLOW: 450 GAL/DAY TABLE 6-1 PROPOSED SI`pTIC TANK MATERIAL: CONCRETE MINIMUM REQUIRED SEPTIC TANK CAPACITY: 1,000 GALLONS TABLE 9-1 SOIL TYPE: USDA SOIL CLASSIFICATION: SANDY CLAY LOAM TACTILE EVALUATION TREATMENT LEVEL: TO PROPOSED Tt7EATMENT SYSTEM: CHAMBERS IN TRENCH CONFIGURATION METHOD OF t.FFLUENT APPLICATION: GRAVITY LONG TERM ACCEPTANCE RATE (LTAR): 0.35 GAL/DAY/SQ. FT. TABLE 10-1 REQ'D SOIL TREATMENT AREA:A=45Q GPD 1 286 SQ. FT. FORMULA 43.10.0 0.35 GPD/S.F. ' SIZE ADJUSTMENT FACTOR FOR APPLICATION METHOD: 1.0 TABLE 10-2 SIZE ADJUSTMENT FACTOR FOR DISTRIBUTION MEDIA: 0.7 TABLE 10-3 ADJUSTED SOIL TREATMENT AREA: A=2,625 SQ. FT. x 0.7 = 900 SQ. FT. MINIMUM NUMBER OF CHAMBERS: 900 S.F. = 75 CHAMBERS 12 S.F./CHAMBER RECOMMEND INSTALLING 75 STANDARD INFILTRATOR QUICK 4 PLUS CHAMBERS IN 3 PARALI EL TRENCH CONFIGURATION, AS SHOWN. 3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS PRESENT. 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE TANK AND ON THE FIELD. 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 150 FEET ALONG THE EFFLUENT LINE. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS AT OR ABOVE THE FINAL GRADE, 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE PONTIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY. 9. THE CONTRACTOR SHALL VERIFY ALL DEPTHS, SLOPES AND CLEARANCES FROM THE PROPO=SED HOME, WELLS AND STRUCTURES, PRIOR TO CONSTRUCTION. 10. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE COUNTY OFFICIALS. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SEPTIC TANK SHALL HAVE RISES OVER EACH ACCESS MANHOLE AND ALL RISERS SHALL EXTEND TO OR ABOVE FINAL GRADE. 13. THE CONTRACTOR SHALL VERIFY ADEQUATE SEPARATION DISTANCES PRIOR TO CONSTRUCTION, 14. THE APPLICANT OR LICENSED INSTALLER SHALL NOTIFY THE COUNTY AND THE ENGINEER NO LESS THAN TWO BUSINESS DAYS IN ADVANCE TO SCHEDULE A FINAL FIELD INSPECTION OF THE SYSTEM, PRIOR TO BACKFILLING THE SYSTEM. 15. THE APPLICANT OR LICENSED INSTALLER SHALL PROVIDE AN AS -BUILT DRAWING OF THE SYSTEM TO THE COUNTY AND ENGINEER, UPON COMPLETION. 16. PLACE 2" BLUE BOARD INSULATION ABOVE ALL PIPES WHENEVER DEPTH IS LESS THAN FROST DEPTH. 17. ALL SEWER I INES SHALL BE 4 -INCH DIAMETER POLYVINYL CHLORIDE (PVC) SCHEDULE 40, AND SHALL BE INSTALLED WITH MINIMUM SLOPES NO LESS THAN 2X 18. THE EXISTING; TOPOGRAPHIC CONTOURS SHOWN HEREON WERE OBTAINED FROM THE BUREAU OF LAND MANAGEMENT. 19. THE PROPERTY BOUNDARY AND FEATURES SHOWN HEREON WERE OBTAINED FROM THE " ° BY RICHARD L. HOLSAN, DATED 2 13 98. 20. THE EXISTING SEPTIC SYSTEM SHOWN HEREON WAS OBTAINED FROM THE "reRVIFI n eni LAITY RI III nimr. AND SANITATION DEPARTMENT PERMIT. 282 DATED ABSORPTION TRENCH NOTES 1. ABSORPTION TRENCH LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND TRENCH, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. ABSORPTION TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION, 5. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER TRENCH AREA IS PROHIBITED TO MAINTAIN GOOD SOIL STRUCTURE. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 7. CONTRACTOR SHALL INSTALL 4 INCH DIAMETER SCHEDULE 40 PVC INSPECTION PORTS AND CAPS AT BOTH ENDS OF EACH ROW OF CHAMBERS, IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 8. CONTRACTOR SHALL SNAP OFF THE MOLDED SPLASH PLATES LOCATED AT THE BOTTOM OF THE END CAPS, AND INSTALL THE SPLASH PLATES AT THE APPROPRIATE SLOTS BELOW THE INLETS IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 9. CONTRACTOR SHALL ALIGN THE CHAMBER ROWS PARALLEL WITH THE THE CONTOURS OF THE EXISTING TERRAIN. THE CONTRACTOR MAY CURVE THE ALIGNMENT OF THE CHAMBER ROW, AS NECESSARY. IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 10, CONTRACTOR SHALL PROVIDE AND VERIFY A MINIMUM 4 FEET OF DEPTH, OR GREATER FROM THE BOTTOMS OF INSTALLED CHAMBERS TO CONFINING BEDROCK. 11. CONTRACTOR SHALL PROVIDE AND VERIFY A MINIMUM 2.5 FEET OF COVER, OR GREATER FROM THE BOTTOMS OF INSTALLED CHAMBERS TO FINISH GRADE. 12. CONTRACTOR SHALL CONNECT THE 4 INCH DIAMETER PVC THE DISTRIBUTION LATERAL PIPES AT THE MOLDED CIRCULAR BLOCK OUTS. WHICH ARE SITUATED 8 INCHES ABOVE THE BOTTOMS OF THE STANDARD QUICK 4 PLUS CHAMBER END CAPS, IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES 13. DISTRIBUTION BOX, ROTO -FLOW WEIRS, RISERS, AND LID SHALL BE # DBOX 8C A PRECAST CONCRETE BOX ASSEMBLY MANUF. BY VALLEY PRECAST INC. OR, EQUAL VO .• t 0 Tj . GPt 9399 t�'o �•. z/4�fz2 : ,www ��S�OfVAL EQ��.c FOR AND ON BEHALF OF HIGH COUNTRY ENGINEERING, INC. W U Z Z } OO�W o um�0 z L.0 r [_ w 00 (V � ZO(,jZ >.LLLO :Ix 00 z WOo m �Lu ¢ U � - K d 0 N N 0 � r � O N (n w Ed > Y o 0 U 4N Z d w� Up O in L0 Z �N 0. to w 0014 w La -� }� }- T fo Co xo ww Z v mus U 4 W tn ry Z Z0LL WZ- Z W w ¢dS U p% WN00 = In is N j-. Z 1061 r,Zh �W� TOZ 2 (L �Z V 2 PROJECT NO. 221 1065.00 OWTS - 01 C1 4N d w� Up O z Od O 0. to w ::) u w La -� }� }- C9 xo ZZ 4 �ED > ry �O Cq W J U p% 9 P is N PROJECT NO. 221 1065.00 OWTS - 01 C1