Loading...
HomeMy WebLinkAboutOWTS Designr" - _ r - - - UE TrY /. --- _ _ ----- ---- � -:- "_- / _- N OT LOCATED) XISTING 1" CURB �x XISTING WATER '- - MAI N� \ -__._._.--- ��-------60.D'ROW � � � = � STOP AND WATER __ ---- EASEMENT - METER 500 GALLON-- 2 ALLO 2 COMPARTMENT SEPTIC _TANK O EXISTING 1" 5' BEND0-- } - ---- - MANWAY RIMS=5689.33' PURCORE WATER !-"' WITH 4' PIPE INVERT TO CHAMBERS 5686.45'INV. IN=5687.13' / SERVICE � CLEANOUT =. - INV. OUT=5686.88' '� = - �-�----_--------...- �=1NV.-5687.38' � _- 39.0'ABSORPTION. SOP OF CNAMSERS=5687.00' BOTTOM OF TANK=5681.63 FIELD TO COMMUNITY _ WATER MAIN 3 -WAY DISTRIBUTION_ 45° BEND ---_�_ BOX (CONTRACTOR TO GET _AND 22.5' _ ENGINEER APPROVAL OF DETAIL)_. - � BEND WITH 45' BEND � WITH CLEANOUT. FLOWLINE=5686.76' i 39-9'ABSOROPTION - } - - INSPECTION PORT -- FIELDTOWATERLINE 4 CLEANOUTS / INV.=5687.52' .(TYPICAL) _ - -G.O' (18 UNITS - _ i'"`�- 167 TANK _ 4" SEWER SERVICE i TO. �L _ _ _ - - -- '/ WATER INV ®WATER LINE ONCRETE ENCASE _ - \` __✓- CROSSING= 5689.00' SEWER- LINE WITHIN _ (APPROX. WATER ! 10' OF THE WATER SERVICE ELEVATION rSERVICE CROSSING } \�� SWALE DRAINAGE 135- / 5686.50'-5687.50') 4., SEWER SERVICE ---�.` AROUND FIELD _ p ,/ / - ION INV @ STORM SEWER TEST HOLELOCAT0 3 CROSSING= 5689.38' -2% SLOPE GRAVITY PERCOLATION = �`'- /"--- --`SCH 40 PVC SEWER }\_--$Ef2COLATIO TEST HOLE #2 �� �' ALINE TEST HOLE #1 - _ �� �.�-� SEWER CLEANOUT _� --- INV. 5690.00' -SEWER CLEANOUT 23 / TO NEAREST --.-/ _ -j4.SCH 40 PVCE_- -yINV. 5690.15' 569�0.15' PROPERTY 22.5' BEND - LINE SEWER SERVIC - - WIT E'`i ER -CLEANOUT OU' §.' '!- t - --- "' RV SEWAGE 40 DUMP LOCATION f•/E� Dm_ - 4" STAND IPE /J V12"-24" COVER OF CHAMBERS SE _GROUND OVER CHAMBERS �FG5693.SO BETWEEN 5688'-5689' INV=5689.00' i " �1" WATER SERVICE iTO HOUSE MAINTAIN_. NSTALL 1"x1" ( PURE -CORE WATER 'S:5' OF COVER TO TEE - STOP OF PIPE)MISTING /�YARD HYDRANT i - - 1 _ i'� j �� /% ,/ �-�' ' � ,--� -- _- _--- - � l � i y� iii- � � _, / j.-/ / .: ---- --�`✓ ./� �, -' ,,, �i � �, //,/ LEGEND - ROW EASEMENT '.. LOT LINE ------ BUILDING SETBACK EASEMENT -- -- -- EXISTING 1' MINOR CONTOUR -- -- EXISTING 5' MAJOR CONTOURS - - PROPOSED 1' MINOR CONTOURS j Gam- PROPOSED 5' MAJOR CONTOUR I GRAVEL DRIVEWAY EXISTING GRAVEL DRIVEWAY GRAPHIC SCALE 20 0 M 20 40 80 (IN FEET) 1 inch = 20 ft: GENERAL NOTES 1, ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY REGULATIONS OF ONSITE WASTE WATER TREATMENT SYSTEM (OWTS) REGULATIONS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS.. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS AREREFERREDTO IN THE ABOVE MENTIONED REGULATIONS. 2. WASTE WATER FLOW (TABLE 6-1): SINGLE FAMILY. HOUSE (5. BEDROOMS) (75 GAL/PERSON/DAY X 8 PERSONS X 5 BEDROOMS) DESIGN FLOW =.Q = 600 GALLONS/DAY - 3. SEPTIC TANK: MINIMUM TOTAL TANK SIZE (TABLE 9-1): 5 BEDROOM = USE 1500 GALLONS INSTALL ONE 1,500 -GALLON TANK WITH BAFFLE ***INSTALL BIO -FILTER IN SEPTIC TANK OUTLET*** 4. SOIL TREATMENT AREA (SQUARE FEET) REQUIRED = DESIGN FLOW (GAL/DAY) LTAR (GAL/DAY/SF) SOILS ANALYSIS PERFORMED BY GEOTECHNICAL ENGINEERING GROUP SHOWED A AVERAGE PERCOLATION RATE FOR THE THREE TEST HOLES OF 8.3 MIN/INCH. THIS FALLS WITHIN SOIL TYPE 1 ACCORDING TO TABLE 10-1. LTAR FOR SOIL TREATMENT LEVEL 1 IS 0.80. = 6 0 GPD = 750 SF 0.80 SIZE ADJUSTMENT FACTOR FROM TABLE 10-2: - USE 1.0 FOR A GRAVITY TRENCH TREATMENT AREA 1250x1.0=750 SF AREA OF THE ADS ARC 36 CHAMBERS (60 INCHES x 34 INCHES)= 14.17 SF 750 SF/1417 SF = 53 UNITS -> USE 54UNITS (3 TRENCHES X 18 CHAMBERS). 4. .SOIL INVESTIGATION INFORMATION WAS PROVIDED GEOTECHNICAL ENGINEERING GROUP (JOB NO.. 4645) ON AUGUST 26, 2021. THE PERCOLATION RATE AND SOIL DESCRIPTION RESULTS IN A LONG-TERM ACCEPTANCE RATE OF 0.80 GAL/DAY/SQUARE FOOT. THE PERCOLATION RATE FOR THE TEST LOCATIONS AT THE ABSORPTION FIELD OF 5-11 MIN./INCH CONFIRMED THE SAME LTAR AS THE GRADATION. FROM TABLE 10-1 THE SOIL IS CLASSIFIED AS SOIL TYPE 1 AND REQUIRES TREATMENT LEVEL 1. 5. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE GRAVITY SANITARY SEWER LINE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 7. TOPSOIL COVER MAY BE VARIED (WITH. 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 8, INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 9. LOCATIONS OF ALL. COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES. AND SLOPES MEET THOSE REQUIRED. 10. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 11. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE COUNTY OFFICIALS. THE ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. 12. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. - 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. OWNER RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING TOILETS AND RUNNING WATER IS NOT ACCEPTABLE AND MAY OVERLOAD THE DESIGNED SYSTEM - 16. HIGH YSTEM.16.HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS. 16 MINIMUM GRADE OF SEWER SHALL BE 1/4" PER LINEAR FOOT. GENERAL ABSORPTION TRENCH NOTES 1. ABSORPTION TRENCH SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF THE ABSORPTION TRENCH SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND TRENCH, AS NECESSARY, TO PREVENT SURFACE RUNOFF CHANNELIZED FLOW FROM ENTERING THE ABSORPTION AREA. 4. ABSORPTION. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 5. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER BED AREA IS PROHIBITED TO MAINTAIN GOOD SOIL STRUCTURE. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 10 live� +� !_ a TRENCH I WIDTH = 36' SECTION A,A NOTES: 1. EXCAVATE TRENCHES TO PROPER WIDTH, AND PROPER DEPTH AS REQUIRED BY STATE AND LOCAL CODES. 2. SMOOTH IRREGULARITIES IN THE EXCAVATION. A LEVEL, FLAT SURFACE IS REQUIRED. 3. ASSEMBLE ARC LEACHING CHAMBERS AND UNIVERSAL ENDPLATES TOGETHER IN TRENCHES). 4. INSTALL UNIVERSAL END CAP AND SECURE IN PLACE WITH BACKFILL. 5. PUNCH OUT PIPE HOLE OPENINGS IN THE END PLATES AS NEEDED AND CONNECT INLET PIPES. •aoo„ns, I W - ADS SEWER & URAIN AND/OR ADS TRIPLEWALL OR PER LOCAL RE^' .. " '^" j iAMBER HEIGHT 13' f DISTRIBU' 6. FILL SIDEWALL AREA TO TOP CHAMBERS WITH NATIVE SOIL (COARSE SAND OR FINE GRAVEL, MAY ALSO BE USED: NO HEAVY CLAY, SILT, OR DEBRIS SHALL BE INCLUDED.) 7. "WALK IN" FILL TO COMPACT SOIL ALONG SIDES OFARC CHAMBER. THIS IS VERY IMPORTANT TO ACHIEVE LOAD RATING. & COVER ARC LEACHING CHAMBERS TO A MINIMUM OF 12" OF GRANULAR COVER AFTER CONSOLIDATION FOR H-10 APPLICATIONS. AVOID LARGE ROCKS OR DEBRIS IN COVER MATERIAL. COVER HEIGHTS AND LIVE LOADING LIMITS ARE IMPACTED BY BOTH SOIL TYPE AND COMPACTION REQUIREMENTS. CONTACT ADS WHEN POOR SOILS ARE ENCOUNTERED AND FOR MAXIMUM FILL HEIGHTS. REV. I DESCRIPTION I BY I MMIDOM I CHK'D BY STATF CODES ti• 1*'!i 1 )'7F �lrr1.. ' + rr ..r •r ! ! :, ii 1 f _ • �..♦ 'r/ A • ) ;� - __ /` 1 Iy1 f !7• # '1 tl ! 31 './ ♦ T. r':. '�+ .tly• r' IA.. "r ISL ra •- a r/ a t / :; 1 ■ ,z' 1` ••. f� a aR• � _ _ y.. I�� .. 1.� 1 .• I. >t 1. •'.f...:• ►.. _ ti 7 i yT". ^.3. •! � ! 7. / �+I� 03:1 Y.tA+N:. f. I:.f - il.ill � � •■ • •+ "vlxx _..�.—_._ mrsamueseew a.+.'..rw�./.ra-r«ab.�.'.*rdtcefa'umntd.e.w.wr 1500 Gallon Top - 132" Top DESIGN NOTES I'— View' • Design per performance test per ASTM •� v 01227 • Top surface area 62.33 ft' • f'c 0 28 days; concrete = 6,000 PSI •� �� <I I_ � Min. Instailatiom • Tank to be set on 5" min. sand bed or• pea gravel • Tank to be backfilled uniformly on all sides in lifts less than 24' and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewotered and tank filed with water prior to being put in service for installation with water table less than 2' below grade • Meets 01644-06 for resilient connectors • Inlet and Outlet identified above pipe m Delivered complete with internal piping • 4' Maximum bury depth ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE ARTH Fl ' 3'-0" i'-0' 3'-0' 0' 4' - 0' 3' - 0' 4' - 0' DRY 4' - 0' RUINrsto Otads Emm Section VIOW Long g —W L We,g Digging Specs overt Dimensions Net CapacityNet Lars z S' Wide Inlet Outlet Length Width ht inlet Side Outlet Toto! !id .�• L-i.d 56" below Inlet 56" 53" 132' 1 66' 68" 1002 gal 507 gait 1509 gal 3600 Ih 1111<' ih•.: 14781., VALLEY 1 Buwm Vista, Colorado 4" 0 SOLID PIPE REMOVABLE PVC CAP SIDES / 11 I1GHENED 177/// INSTALL VERTICAL INSPECTION PIPE AT END CAP OF INFILTRATOR UNITS. 0 0 L-4" 0 0 PERFORATED PIPE I —I PIZ —I AADS INFILTRATOR ADS INFILTRATOR IIIUNIT &END CAP. UNIT & END CAP. IIITI:I NATURAL—� \ 3' OF CONCRETE SAND GROUND `FOR INFILTRATION UNDER CHAMBERS PER CODE. INSPECTION PORT DETAIL N.T.S.