HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT
BLRE-O1-22-7321
LISA & RYAN BRISCOE
NEW SINGLE.FAMILY DWELLI NG
TBD GARDEN CIR, NEW CASTLE
GILEAD GARDENS, LOT 6 - 21 B1O73O3OOó
1 ) ALL WORK SHALL COMply W|TH THE 201 5 INTERNATIONAL RESIDENTIAL CODE
(r.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC
BOARD, ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION.
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION
AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE
AND LOCAL F]RE DISTRICT,
5) PRE-FABRTCATED ROOF TRUSSES. HAVE ENGINEER|NG FOR INSPECTOR AT TIME
OF FRAME INSPECTION.
ó) opEN HOLE SOTLS REPORT tS REOUIRED AT FOOTING INSPECTION AND PRIOR TO
ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT
TO THE BUILDING INSPECTOR (2,500 PSF).
7) A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED
SURVEYOR. IS REQUIRED AT FOUNDATION INSPECT]ON TO VERIFY STRUCTURE -
]NCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS _ IS IN
COMPLIANCE WITH MINIMUM SETBACKS AND/OR BUILDING ENVELOPE
REOUIREMENTS.
B) ENGINEERED SEPT]C SYSTEM: ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
TO BE INSPECTED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
COLORADO. PROVIDE ENGINEER'S FINAL REPORT PRIOR TO FINAL BUILDING
]NSPECTION & CERTIFICATE OF OCCUPANCY.
9) STAPLED TO OFFTCE & FTELD COPY ARE RECORDED PLAT NOTES (RECEPTION
733131)FOR GENERAL BUTLDER REFERENCE & GUIDANCE CONCERNING RADON
MITIGATION,