Altitude Septic LLC was hired to perform an ¡nspect¡on at the above address. This system cons¡sts of a 1000-
gallon concrete septic tank with a leach field located in the field below. The septic tank fails the inspection as it
is leaking and has deteriorated enough to allow roots to infiltrate it. The leach field appears to be functioning,
but it hasn't been used for more than a year, so ¡t is d¡fficu¡t to verify this, but, it shows no signs of previous
saturation or failure.
lf you have any questions, please call me at97O-47L-1330.
Jason Daubs
Altitude Septic
970-47L-09L3
please be aware of the following disclaimer: Altitude Septic øccepts no responsibility for the proper operation of this septic system. The
septic system is the propefty of the homeowner who is respoasibleþr the maintennnce and operation of the system. This inspeaion does not
constitate a guarantee nr is any wørranty expressed or implied that the system will fi"tnction properb in thefutura Altitude septic can only
maþe obsemations based an thi condition of the septic system at the time of inspec'tion and will meþe no prediction on thefuturefunaionality of
any part ofthe septic syst€m.
IOOO Gallon Top Sealll - ZG}Pñmt
looor.æP
11 Top
ViewDES¡GN NOIESr Design per performonce test Per
ASTU C1227
o Top surfoce oreo 46.25 ft2
¡ fc O 28 do)rs: concrete = 6,OOO PSI
Min.
lnstollotion:o Tonk to be set on 5" min. sond
bed or peo grovelo Tonk to be bockfilled uniformly on
oll sides in lifts less thon 24" ond
mechonicolly comPoctedo Excovoted mcteríol moy be used for
bockfìll, provided lorge stones ore
removedr Excovotion should be dewotered ond
tonk filled with woter prior to being
put ín service for ínstollotíon with
woter toble less thon 2' below grode
o Meets C164¿t-06 for resilient
connectorsr lnlet ond Outlet identified obove pt'pe
r Delivered complete with internol
piping
o C Moximum bury dePth
..---.ú
-a'
GSTAæ
T tl(
D
=-ø1 '.'a
b Glado
Fle¡dt¡þ RrËôor
SæFü
6l I'
Section
Mevv
Dígging Specs lnvert Dimensions Net Copocity Net Weight
11' Long x 7' tìlide
56" below inlet
Length tt4dth Side Outlet Tonk Totol
56"53"111"60"687 gol 523 gol lbs 938O lbs 12000 lbs
ALLOWABLE BURY
(Bosed on Woter Toble)
IVA1ER TABTE AI.LOWABLE
FARÍH FILL
0'-o'z'-O-
1'- O'J'- o'
2'-O'J'- d
3'-O'd-o'
DRY c-o'
1 1
Plnñü 7f9€e5{r![
Fæ,719nffiIinkhtÞ wur.v{eYPeffililn
EüTI: