HomeMy WebLinkAboutEngineer Letter& Tank SpecsOFFICE 97A-47L-ø9L3 P-O. Box 1534 Eagle, CO 81631 altitudesept¡c@gma¡l.com www.altitudeseptic.com 2l4PrinceD¡. Carbondale, CO t2/7l2O2L Altitude Septic LLC was hired to perform an ¡nspect¡on at the above address. This system cons¡sts of a 1000- gallon concrete septic tank with a leach field located in the field below. The septic tank fails the inspection as it is leaking and has deteriorated enough to allow roots to infiltrate it. The leach field appears to be functioning, but it hasn't been used for more than a year, so ¡t is d¡fficu¡t to verify this, but, it shows no signs of previous saturation or failure. lf you have any questions, please call me at97O-47L-1330. Jason Daubs Altitude Septic 970-47L-09L3 please be aware of the following disclaimer: Altitude Septic øccepts no responsibility for the proper operation of this septic system. The septic system is the propefty of the homeowner who is respoasibleþr the maintennnce and operation of the system. This inspeaion does not constitate a guarantee nr is any wørranty expressed or implied that the system will fi"tnction properb in thefutura Altitude septic can only maþe obsemations based an thi condition of the septic system at the time of inspec'tion and will meþe no prediction on thefuturefunaionality of any part ofthe septic syst€m. IOOO Gallon Top Sealll - ZG}Pñmt looor.æP 11 Top ViewDES¡GN NOIESr Design per performonce test Per ASTU C1227 o Top surfoce oreo 46.25 ft2 ¡ fc O 28 do)rs: concrete = 6,OOO PSI Min. lnstollotion:o Tonk to be set on 5" min. sond bed or peo grovelo Tonk to be bockfilled uniformly on oll sides in lifts less thon 24" ond mechonicolly comPoctedo Excovoted mcteríol moy be used for bockfìll, provided lorge stones ore removedr Excovotion should be dewotered ond tonk filled with woter prior to being put ín service for ínstollotíon with woter toble less thon 2' below grode o Meets C164¿t-06 for resilient connectorsr lnlet ond Outlet identified obove pt'pe r Delivered complete with internol piping o C Moximum bury dePth ..---.ú -a' GSTAæ T tl( D =-ø1 '.'a b Glado Fle¡dt¡þ RrËôor SæFü 6l I' Section Mevv Dígging Specs lnvert Dimensions Net Copocity Net Weight 11' Long x 7' tìlide 56" below inlet Length tt4dth Side Outlet Tonk Totol 56"53"111"60"687 gol 523 gol lbs 938O lbs 12000 lbs ALLOWABLE BURY (Bosed on Woter Toble) IVA1ER TABTE AI.LOWABLE FARÍH FILL 0'-o'z'-O- 1'- O'J'- o' 2'-O'J'- d 3'-O'd-o' DRY c-o' 1 1 Plnñü 7f9€e5{r![ Fæ,719nffiIinkhtÞ wur.v{eYPeffililn EüTI: