Loading...
HomeMy WebLinkAboutCorrespondenceê4tr-A4-2/-bgzl Colleen W¡tth sha ilout ê a From: Sent: To: Subject: Looks Like Keith Wittenberg #682L From: Col leen Wírth <cwirth @ garfield-cou nty.com> Sent: Friday, June 4, 2021 10:59 AM To : Andy Schwall er <aschwaller@garfield-cou nty.com> Subject: RE: Foundations Your thoughts and a Heads Up Andy Schwaller Friday, June 4, 2021 1'1:36 AM Colleen Wifth RE: Foundations Yourthoughts and a Heads Up /ârt'e/ futt ,J dþnl E,O,R /C ,{a- d¿nnq fre// n7áchb>os Sure, thanks! Colleen Wirth Plans Examiner Garfield County Building Division L08 8th Street, Suite 40L Glenwood Springs, CO 81601 cwi rth @sarf ield-cou ntv. com office (970) 945-t377 ext. l-610 From: Andy schwaller <aschwaller@garfield-county'com> Sent: Friday, June 4,202110:56 AM To : Col leen Wirth <cwirth @sarf iel d-cou ntv. com > Subject: RE: Foundations Your thoughts and a Heads Up Good euestion. Keith,s phone is 970-948-3101. ln hindsight, they might be amended foundation plans. You might remind him to amend the approved plans if that is the case. From: Col I een Wi rth <cwirth @earf iel d-cou ntv. com > Sent: Friday, June 4, 202L 10:54 AM To: Andy Schwaller <aschwaller@garfield-countv.com> Subject: RE: Foundations Your thoughts and a Heads Up Thanks Andy, You wouldn't happen to recall the job address or permit number? Colleen W¡rth Plans Examiner Garfield County Buílding Division LO8 8th Street, Suite 401 Glenwood Springs, CO 81-60L cwi rth @ sa rf i el d-cou ntv. com office (970) 945-L377 ext. 1610 From: Andy Schwaller <aschwaller@garfield-countv.com> Sent: Fridaç June 4, 2021 10:5L 4M To: Matt Provost <mprovost@garfield-countv.com>; Jim Wilson <iwilson@garfield-countv.com> Cc: Col I een Wi rth <cwi rth C0 sa rf i el d -cou ntv. coln> Subject: Foundations Your thoughts and a Heads Up Keíth and I missed his last name is just getting tlre foundatiurr dug for his project. His engineer is Earny Kollar. Keith came in the office yesterday with a set of Kollar's structural clrawings showing varyíng footer depths with a note to frost protect with foam any footers not deeper than 3 ft. Kollar did not show any vertical foam which was added to the foundation walls via my di3cussion with Keith and Table R403.3(L) Frost Protected Foundations. The engineer approved footer and stem walls both below frost depth and above frost depth. I told Keith to have a letter at the jobsite by the engineer approving the varying depth design based also on the soils engineer review of the bearing soils. I assume this weird design is propped by the cost of concrete. I guess it will work OK but I would not do it to my house. We might see it again. Thanks, Andy 2