From: Col leen Wírth <cwirth @ garfield-cou nty.com>
Sent: Friday, June 4, 2021 10:59 AM
To : Andy Schwall er <aschwaller@garfield-cou nty.com>
Subject: RE: Foundations Your thoughts and a Heads Up
Andy Schwaller
Friday, June 4, 2021 1'1:36 AM
Colleen Wifth
RE: Foundations Yourthoughts and a Heads Up
/ârt'e/ futt
,J dþnl
E,O,R /C ,{a-
d¿nnq fre//
n7áchb>os
Sure, thanks!
Colleen Wirth
Plans Examiner
Garfield County Building Division
L08 8th Street, Suite 40L
Glenwood Springs, CO 81601
cwi rth @sarf ield-cou ntv. com
office (970) 945-t377 ext. l-610
From: Andy schwaller <aschwaller@garfield-county'com>
Sent: Friday, June 4,202110:56 AM
To : Col leen Wirth <cwirth @sarf iel d-cou ntv. com >
Subject: RE: Foundations Your thoughts and a Heads Up
Good euestion. Keith,s phone is 970-948-3101. ln hindsight, they might be amended foundation plans. You might
remind him to amend the approved plans if that is the case.
From: Col I een Wi rth <cwirth @earf iel d-cou ntv. com >
Sent: Friday, June 4, 202L 10:54 AM
To: Andy Schwaller <aschwaller@garfield-countv.com>
Subject: RE: Foundations Your thoughts and a Heads Up
Thanks Andy,
You wouldn't happen to recall the job address or permit number?
Colleen W¡rth
Plans Examiner
Garfield County Buílding Division
LO8 8th Street, Suite 401
Glenwood Springs, CO 81-60L
cwi rth @ sa rf i el d-cou ntv. com
office (970) 945-L377 ext. 1610
From: Andy Schwaller <aschwaller@garfield-countv.com>
Sent: Fridaç June 4, 2021 10:5L 4M
To: Matt Provost <mprovost@garfield-countv.com>; Jim Wilson <iwilson@garfield-countv.com>
Cc: Col I een Wi rth <cwi rth C0 sa rf i el d -cou ntv. coln>
Subject: Foundations Your thoughts and a Heads Up
Keíth and I missed his last name is just getting tlre foundatiurr dug for his project. His engineer is Earny Kollar. Keith
came in the office yesterday with a set of Kollar's structural clrawings showing varyíng footer depths with a note to frost
protect with foam any footers not deeper than 3 ft. Kollar did not show any vertical foam which was added to the
foundation walls via my di3cussion with Keith and Table R403.3(L) Frost Protected Foundations.
The engineer approved footer and stem walls both below frost depth and above frost depth. I told Keith to have a letter
at the jobsite by the engineer approving the varying depth design based also on the soils engineer review of the bearing
soils. I assume this weird design is propped by the cost of concrete. I guess it will work OK but I would not do it to my
house. We might see it again.
Thanks,
Andy