Loading...
HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT BLRE- 12-21 -7280 James & Amy Redman New S/F Dwelling with attached gtrage TBD Scutter Ln, Rifle, CO s.28, T.05, R92 212728400390 1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATTONAL RESTDENTIAL CODE (l.R.C.) AND 2009 TNTERNATIONAL ENERGY CONSERVATION CODE (|.E.C.C.) 2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE IÏEMS CONTAINED lN THE ATTACHED "GARFI ELD COU NTY BUI LDING REOUI REMENTS". NU M B ER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LISÏ. 3) ELECTRICAL pERMtTTtNc AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. 5) PRE-FABRTCATED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION. ó) opEN HOLE SOTLS REPORT tS REOUTRED AT FIRST FOOTING INSPECTION. REPORT MUST BE PREPARED BY GEOTECHNICAL ENGINEER OF RECORD. 1,500 PSF. 7) ENGINEERED SEPTIC SYSTEM: ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS)TO BE INSPECTED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE ENGINEER'S FINAL REPORT PRIOR TO FINAL BUILDING INSPECTION & CERTI FICATE OF OCCU PANCY. 8) tF BONUS ROOM ABOVE GARAGE REMAINS OPEN TO THE STAIR / GARAGE DOORWAY BELOW, THEN ROOM SHALL NOT BE PERMITTED FOR FUTURE USE AS A BEDROOM / SLEEPING SPACE PURSUANT TO THE 2015 IRC SECTION R302.5.1 AND TABLE R302.ó.