HomeMy WebLinkAboutSubsoil StudyHuddleston-Berry
Engineering & Testing, LLC
2789 Riverside Parknay
Grand Jru¡ction, Colorado 81 50 1
Phone: 970-255-8005
Info@huddlestonberry. com
October 26,2021
Project#02347-00A1
Sarah Moon
2334 Acacia Avenue
Rifle, Colorado 81650
Subject:
IIETEIVEO
,4Plr u 8 iltÌi
-r,îfir,iFi,'.Ê,o#ilJ^I
Geotechnical Investigation
5620 County Road342
Silt, Colorado
Dear Ms. Moon,
This letter presents the results of a geotechnical investigation conducted by Huddleston-Berry
Engineering & Testing, LLC (I{BET) for 5620 County Road 342 in Silt, Colorado. The site
location is shown on Figure 1 - Site Location Map. The proposed construction is anticipated to
consist of a single-family residence. The scope of our investigation included evaluating the
subsurlace conditions at the site to aid in developing foundation recommendations for the
proposed construction.
Site Conditions
At the time of the investigation, the site was heavily vegetated by large bushes and trees and
generally sloping down towards the south. Vegetation consisted of grasses, weeds, and small to
large bushes and trees. The site was bordered to the north by a vacant property, to the west by
open land, to the south by a rural residential properfy, and to the east by County Road 342.
Subsurface Investigation
The subsurface investigation included six test pits at the site as shown on Figure 2 - Site Plan.
The test pits were excavated to depths ranging from 3.0 to 7.0 feet below the existing ground
surface. Typed test pit logs are included in Appendix A.
As indicated on the logs, the subsurface conditions at the site were slightly variable. Test Pits
TP-l through TP-3, conducted in the westerly investigated area, encountered 1.0 foot of topsoil
above brown, moist, dense clayey sand soils to the bottoms of the excavations. Groundwater was
not encountered in TP-l, TP-z, or TP-3 at the time of the investigation.
Test Pits TP-4 through TP-6, conducted in the easterly investigated are4 encountered 1.0 foot of
topsoil above brown, moist, stiff sandy lean clay soils to the bottoms of the excavations.
Groundwater was not encountered in TP-4, TP-5, or TP-6 at the time of the investigation.
Laboratory Testing
Laboratory testing was conducted on samples of the native soils collected from the test pits. The
testing included grain-size analysis, Atterberg limits determination, and natural moisture content
determination,. The laboratory testing results are included in Appendix B.
5620CF.342
#a2347-OOOI
ß/26121
Ã
@ €nÊir¡..r¡nt ! Tc{in¡, l.l.c
Huddleston-Berry
The laboratory testing results indicate that the native sand soils range from slightly to moderately
plastic. In general, based on the Atterberg limits and our experience with similar soils in the
vicinity of the subject site, the native clay soils are anticipated to range from slightly collapsible
to slightly expansive.
In addition, the laboratory results indicate that the native clay soils are slightly plastic. In general,
based on the Atterberg limits and our experience with similar soils in the vicinity of the subject
site, the native clay soils are expected to be slightly collapsible.
Foundation Recommendations
Based upon the results of the subsurface investigation and nature of the proposed construction,
shallow foundations are generally recommended. Spread footings and monolithic (turndown)
structural slab foundations are both appropriate alternatives. However, as discussed previously,
the native soils are anticipated to range from slightly collapsible to slightly expansive.
Therefore, in order to provide a uniform bearing stratum and reduce the risk of excessive
differential movements, it is recommended that the foundations be constructed above a minimum
of 24-inches of structural fill.
In general, with careful moisture control and proper compaction, the native soils may be reused
as structural frll. Imported structural fill should consist of a granular, non-expansive, qon-free
drainins material approved by F{BET.
For spread footing foundations, the footing areas may be trenched. However, for monolithic slab
foundations, the structural fill should extend across the entire building pad area to a depth aî24-
inches below the turndown edges. Structural fill should extend laterally beyond the edges of the
foundations a distance equal to the thickness of structural fill for both foundation types.
Prior to placement of structural fill, it is recommended that the bottom of the foundation
excavation be scarifîed to a depth of 6 to 8 inches, moisture conditioned, and compacted to a
minimum of 95a/o of the standard Proctor maximum dry density, within *2Yo of the optimum
moisture content as determined in accordance with ASTM D698. Structural fill should be
moisture conditioned, placed in maximum 8-inch loose lifts, and compacted to a minimum of
95% of the standard Proctor maximum dry density for fine grained soils and 90% of the modified
Proctor maximum dry density for coarse grained soils, within +2o/o of the optimum moisture
content as determined in accordance with ASTM D698 and DI557, respectively.
Structural fill should be extended to within O.l-feet of the bottom of the foundation. No more
than 0.l-feet of gravel should be placed below the footings or turndown edge as a leveling
course.
For structural frll consisting of the native soils or imported granular materials, and foundation
building pad preparation as recommended, a maximum allowable bearing capacity of 1,500 psf
may be used. In addition, a modulus of subgrade reaction of 15û pci may be used for structural
fill consisting of the native soils and a modulus of 200 pci may be used for suitable imported
structural fill. Foundations subject to frost should be at least 36 inches below the finished grade.
Water soluble sulfates are common to the soils in Western Colorado. Therefore, at a minimum,
Type I-II sulfate resistant cement is recommended for construction at this site.
2:\2008 ALL PROJECTS\02347 - Samh Moon\02347-Û00t 5620 CR 342\200 - Geo\02347-0001 LRI02621 doc 2
5620CF.342
#0234"1-0p,01
10/26121
Huddleston-Berry
Any stemwalls or retaining walls should be designed to resist lateral earth pressures. For backfill
consisting of the native soils or imported granular, non-free draining, non-expansive material, we
recommend that the walls be designed for an equivalent active fluid unit weight of 55 pcf in
areas where no surcharge loads are present. An at-rest equivalent fluid unit weight of 75 pcf is
recommended for braced walls. Latercl earth pressures should be increased as necessary to
reflect any surcharge loading behind the walls.
Non-Structural Floor Slab and Exterior Flatwork Recommendations
In order to limit the potential for excessive differential movements of slabs-on-grade it is
recommended that non-structural floating floor slabs be constructed above a minimum of 18-
inches of structural hll with subgrade preparation and fill placement in accordance with the
Foundstion Recommendations section of this report. It is recommended that exterior flatwork be
constructed above a minimum of l2-inches of structural fill.
Drainage Recommendations
Gradins anrl are critical to the lons-term of the structure.Grading
around the structure should be designed to carry precipitation and runoff away from the
structure. It is recommended that the finished ground surface drop at least twelve inches within
the first ten feet away from the structure. It is also recommended that landscaping within five
feet of the structure include primarily desert plants with low water requirements. In addition, it
is recommended that automatic irrigation, including drip lines, within ten feet of foundations be
minimized.
FIBET recommends that surface downspout extensions be used which discharge a minimum of
15 feet from the structure or beyond the backfill zone, whichever is greater. However, if
subsurface downspout drains are utilized, they should be carefully constructed of solid-wall PVC
and should daylight a minimum of i5 feet from the structure. In addition, an impermeable
membrane is recommended below subsurface downspout drains. Dry wells should not be used.
In order to limit the impacts of surface water on the structure, a perimeter foundation drain is
recommended. In general, the perimeter foundation drain should consist of prefabricated drain
materials or a perforated pipe and gravel system with the flowline of the drain at the bottom of
the foundation (at the highest point). The prefabricated drain materials or gravel should extend
along basement walls to within 36-inches of the finished grade. The perimeter drain should
slope at a minimum of L0% to daylight or to a sump with pump. The drain should also include
an impermeable membrane at the base to limit the potential for moisture to infiltrate vertically
down below the foundations.
Onsite Wastewater Treatment System Feasibilitv
In order to evaluate the site soils for onsite wastewater treatment, percolation testing was
conducted at the site. The percolation rate in the native soils ranged from 7 to 27 minutes-per-
inch. The percolation testing data are included in Appendix C.
In accordance with Garfield County regulations, a percolation rate of between 5 to 60 minutes-
per-inch is required for soils to be deemed suitable for onsite wastewater treatment. Therefore,
based upon the results of the percolation testing, HBET believes that the native soils are suitable
for onsite wastewater treatment.
EnBiôcc¡in¡I T.{ilr*. Ll-C
-)2:\2008 ALL PROJECTS02347 - Samh À'foan\02347-0001 5620 CR 342U00 - Geo\02347400 I LRI 02621 doc
5620CR342
#02347-0001
10t26121
Huddleston-Berry
ErSir.c¡i¡fl & f.riit!, lt.C
In addition to the percolation rate of the subsurface materials, the seasonal high groundwater
elevation is an important factor in determining the suitability of the site for Onsite Wastewater
Treatment Systems. For OWTS suitability, the seasonal high groundwater elevation should be at
least four feet below the bottom of the proposed absorption bed. As discussed previously,
groundwater was not encountered at the time of the investigation. In general, based upon the
results of the subsurface investigations, HBET believes that the seasonal high groundwater level
is deeper than 8.0 feet below the existing grade at this site.
General Notes
The recommendations included above are based upon the results of the subsurface investigation
and on our local experience. These conclusions and recommendations are valid only for the
proposed construction.
As discussed previously, the subsurface conditions encountered in the test pits were slightly
variable. However, the precise nature and extent of subsurface variability may not become
evident until construction. As discussed previously, it is recommended that FIBET provide
construction materials testing and engineering oversight during the entire construction process.
In addition, the builder and any subcontractors working on the project should be provided a copy
of this report and informed of the issues associated with the presence of moisture sensitive
subgrade materials at this site.
It is ìmportflnt to note thaf the recommendatíons hereín are infended to reduce the rísk of
conditions ønd/or the precíse mngnítude or eñent of volume change Where signifrcemt
ancre&ses ln &ce moisture occur to Doûr sradíns.stormtonter
man&çement, utilitv line føilure, excess írrigøt¡on, or other cause, eíther duríng construet¡on
or the result of uctions of the protte4y owner, several inehes of movement øre possible. fe
øeldition, unv faílure to complv tyíth the recommendations in this reoort releøses Hucldleston-
Berv Ensìneeríns & Testíne. ILC of anv liubilítv il,íth regard to the structure performünce.
We are pleased to be of service to your project. Please contact us if you have any questions CIr
comments regarding the contents of this report.
Respectfully Submitted :
Iluddleston-Berry Engineering and Testing, LLC
Michael A. Berry, P.E.
Vice President of Engineering
4
0103
Z:\2008 Al.f. PROJËCTS\02347 - Strah Moon\02347-0001 5620 CR 34lut0 - Geo\02347{001 LRl0262 l.doc
FIGURES
G)qPublic.Jtêt"' Garfield County, CO
G¿rfield-Mesa Cou Line
FIGURE 1
Site Location Map
N
ÅI l¿orrt I
G)qPublic.het"' Garfield County, CO
APPENDIX A
Typed Test Pit Logs
Huddleston-Berry Engineerhg & Testing IIC
2789 Riverside Parkway
C¡rand Junctiør, CO 815ût
97ù255-8005
TEST PIT NUMBER TP.I
PAGE 1 OF 1
PROJECT NIME 5620 CR 342
PRO'ECTLOCATION SiIT, COPROJECT NUMBER 023474001
CLIENT Sarah Moon
TEST PIT SIZEDATE STARIÍEÐ Sf24N1 OOMPLETED SN4f21
EX$VAT¡ON CþNTRACTOR Client
CHECKEDBY MAB
EXCAVATION METHOD Trackh/Backhoe
GROUND ELEì'ATION
ATENDOFEXCAVAION dry
AFTEREXCÂVATION _-
LOGGEDBY SD
t{oTEs
GROUND WATER LE\IELS:
AT TIME OF EXGAVATION drv
ATTERBERG
LIMITSrlj
o_>(F r.rl
5go-=>2.
6)
ès
üags
ul
É.
<DU>r-f
=z.JHasoz.
¿
r¡¡o-r--Õ
i.rl J4
()où
5
F^
=EÉ.o
ttl o\t-
Jz
iD !r_Faz.>oO
oF
l=a'fr
o
F-F
3=
o_
Èqñ
6e
Jo-
Fzt¡lFzoG'()9)
g)
ulztr0.0
.Ë
Tt-o-t¡lo
()
äëv'(l
MATERIAL DESCRIPTION
{1.'.1
ùü
'y..'Ji.',i,ì
Silty Sand with Organics flOPSOIL)
I GB
1
6 32 2A 12 43
Clayey SAND {SC), brown, moist, dense
-"lab Classified GB-1
ó
t--ô(9
dt
J
!>:f
tszo
ù(,
ôi
otooN@Ð
eor
No
Boitom of test pit at
Huddleston-Berry Engineering & Testing LLC
2789 Riverside Parloray
Gra¡rd Junctior¡, CO 815ûl
970-255-8005
TEST PIT NUMBER TP-z
PAGE 1 OF ,I
PROJECT NUMBER 02347&1
PRO''ECT f'¡Aû,E #frcR342
PRO.'ECT LOCANON sitt co
CUENT Sarah Moon
GROUNDWATERLE\IELS:
ÀTNMEOF EXCAVATION
AT ENDOF EXCAVATION
AFTEREXCAVATION _-
TEST PIT SIZE
CHECKEDBY MAB
æMPLETED 9TZ4T21
drv
drvEXCAVATIONMETHOD Trackh/Backhoe
GROUND ELEVATION
LOGGEDBY SD
I\¡OTES
DATESTARTED 9T24N1
EXCAVATION@NTRAGTOR Client
AT-TERBERG
LIMITSulù>oal- ur
3>t
o- -r>2.
U)
èe
ffiaàflı-
u¡
É.
g) lll>t-l<zJ
ãas()=
t.0
IE
It-ù
TJJo
(J
$eo
MATERIAL DESCRIPTION
zril
û_
FÊix J4
ooo-
Et-^
=EÉô
Lll o\É.-
JZ
f,D Fro2>oo
Õ,
3=fr
O
F- l-
3=
l-
añ
6e
J
o_
FzuFzoG-()Ð
g)
ulz
TL
.cf.:'{
¿' j-t
'+,.Jr.'.i i.:..;:-.
:-*..9
Silty Sand with Organiæ (TOPSOIL)
g GB
1 6 27 17 10 31
Clayey SAND with some Gravels (SC), tan, miost, dense
*-Lab Classified GB-1
o
tsoo
cri)al
L.-zo
Ào
Õ¡
É.ooNo
ooo
NsNo
Bottom of test pit at 6.0 feet.
Huddleston-Bqry Engineering & Testing LLC
2789 Riverside Parkway
Crrand Junction, CO 815ûl
970-255-8005
TEST PIT NUMBER TP.3
PAGE 1 OF 1
PRCUECT i¡AME 5620CR342
PROJECT NUMBER 02347{001 PROJECT LOCATION sitf co
CUENT Sarah Moon
TEST PITSIZEDATE STARIÍED 9N4f21 æMPLETED 9N4N'I
CHECKEDBY MAB
EXCAVATION CONTRACTOR Client
EXCAVATION MEtltOD Trackh/Backhoe
GTUNDELRÍATION
ATENDOFE(CAVATION drv
AFTEREXCAVANON _.
LOGGEDBY SD
t{oTEs
GROUNDWATER LE\IELS:
ATTIMEOF EXCAVATION dry
ATTERBERG
LIMITStrlfL>-ËFrx
TgfL =t>2.
Ø
s
ño>q
8É-u¡t
<nû> F:l<zJ;3soz-
z
lJlù!-cirg
OoÀ
5F^
=Eüo
G-Ltl o\É-
-F/z
6FJ_Foz.>o(J
o,
e=
fJ
c)
trr---
3=o-
Fqñ
6ef-ÍL
Fz
UJ
F-zoG'()9)
u)
I.Uz
tL
.tr
Il-ùtuo
0
C)
*ëÊ."o
MATERIAL DESCRIPTION
1
{ ".'
.!
?.*2
'+..'Jrr"ri i
\t ,/ '\¡
!:dr'
Y.r.'i
?'.*
Silty Sand with Organics (TOPSOIL)
Clayey SAND (sc), tan, moist, dense
Bottom of test pit at 3.0 feet.
(tl
tsz
(Lq
N
o
É.ooN@o
oooF
No
0)z
lJ
o
Tdì
Ioul
oU
?
Huddleston-Berry Engineering & Testing I-LC
2789 Riverside Parkway
C¡rand Junctim, CO 81501
97û-255-8005
TEST PIT NUMBER TP/,
PAGE 1 OF 1
PRCT,IECT NAME 5620 CR 342
PROJËCT NUMBER 02347{ü}1 PROJECT LOCAÌION
CLIENT Sarah Moon
GROUND ELEì'ATION
-
TEST PIT SIZE
GROUND I'UATER LE\IELS:
ATTIMEOF Ð(CAVATION drv
DATESTARTEÐ 9T24N1 COMPLETED 9N4T21
EXCAVATION METHOD Trackh/Backhoe
Ð(CÂVATION CONTRACTOR Client
CHECKEDBY IVIAB AT ENDOF B(CAVATION drv
AFTEREXCAVATION _
LOGGEDBY SD
r{oTEs
ATTERBERG
LIMITSz.
tlJ
o_]-cir.9
ooÀ
5F^
==ÞÉ.o
Ll-l ô\v-
L1
nD !x
oz.>oo
Õ,
e=fr
o
trF-
3=
o_
Fqñ
42
o-
Fz
uJFzoG'()1)
u)
UJz
¡.L
u¡o->fr
l--- uJ
5gù:)Z,z.
(t)
s
qa
8s
t¡J
É.
Ø IJJ>L-
Yl<ıo>oz.
rtr
IFfLtllo
00
(J
+öÉ.-(9
MATERIAL DESCRIPTION
,s.,.!
i++:!j..J
ft".l l¡
.r i. '.¡
Silty Sand with Organics {TOPSOIL)
I GB
1
4 28 20 I 67
Sandy Lean CLAY (CL), brown, moist, stiff
""Lab Classified GB'l
Bottom of test at 7.0 feet.
Huddleston-Berry Engineering & Testing LLC
2789 Rirerside Parlrway
Crrand Junctiæ, CO 815O1
970-255-8005
TEST PIT NUMBER TP-s
PAGE 1 OF 1
PROJECT NUMBER V23/.7{'û'I
PrcJECT NAME 56?{JcR342
PRo.'ECT LOCATION s¡lr co
CLIENT Sarah Moon
DATESTARtrEÐ 9'4N1 CO{TIPLETED 9n4n1 TEST PITSIZÊ
EXCAVATION CONTRACTOR Client
CHECKEDBY MAB
EXCAVATION METHOD Trackh/Backhoe
GROUND ELEIIATK}N
ATENDOF Ð(CAVATION drv
AFTERÐ(CAVATION _
LOGGEDBY SD
NOTES
GROUNDWATERLEì'ELS:
ATïMEOF EXCAVATION drv
ATTERBERG
LIMITSu¡o->frFUJ
5gùr>=
U)
s
qa
804-tu
É.
o.0
:ELLE
o
():
oo-ı
(,
MATERIAL ÐESCRIPTION
aD u)>t- l<z.J
ãasoz-
z
¡.rJfLr.-ôix 14
()o
o_
El-^
=Efro
Til Ô\É-)\
'¡r¡ltl
_Foz>o()
ô.
l=a¿
J_
()
F-l-
3=o-
È
Þñ
q2
Fzul
t--z
88
u)ll]ztr
.+:.'$î+
:*il
f¡"{ l¡.
Silty Sand with Organics CIOPSOIL)
Sandy Lean CLAY (cl), brown, moist, stiff
Ì-ff(,
tri
I
g)
l
tszo
o_o
ôi
É.o
N@4
Tout
t--ottl
Bottom of test pit at 7.0 feet.
TEST PIT NUMBER TP.6
PAGE 1 OF 1
PROJECT NUMBER 023474]æ1
PRG'ECT NIIME 562OCR342
PRo.JECT LOCAÏTON SiIt, CO
CLIENT Sarah Moon
Huddleston-Berry Engineering & Testing l-LC
Riverside Parlcnray
C¡r¿nd Junction, CO 81501
974-255-8005
DATESTARÍTED 9N4P'I æMPLETED 9T24T21 TEST PITSIZE
EX$VATIONCONTRACTOR Client
CHECKEDBY fuIAB
EXCAVATION METHOD Trackh/Backhoe
GROUND ELEI/ATION
ATENDOFÐ(CAVATION drv
AFTERÐ(CAVATION ---
LOGGEDBY SD
t\¡oTEs
GROUND WATER LE\'ELS:
AT TIME OF Ð(CAVÀTION drv
ATTERBERG
LIMITSulfL>frt- [rJ
sgfL=t>2.
U)
s
üags
UJt
-
(¿ tll<rJ
3áSl)2.
zulo-
F-Êir l4
oo
o_
5
t-- ^
=EÉ.o
-ôLù o\E:"
-FL1b!x_Foz->oo
cl .
3=fr
o
F- l-
3=
o-
t-qñ
42fL
Þ-zt¡lFz
88
U)
l¡Jz
l!-
I
O-.Ë
o
o
+ıú.-o
MATERIAL DESCRIPTION
1
{1.'.!
i.+:!j..1
T,+
'$,/ \l'-.';
l¿.'$-l¿
-È1..{?'!1].:
Silty Sand with Organics CIOPSOIL)
2
Sandy Lean CLAY (cl), brown, moist, stiff
Bottom of test pit at 3.0 feet.
al
tsz
l
o
ôi
É.ooN@o
ooo
NòNo
U)z
lJoo
I
c0
APPENDIX B
Laboratory Testing Results
Huddleston-Berry Engineerfug & Testing L[.C
2789 Riverside Parlovay
C¡rand Junction, CO 81501
970-255-8005
GRAIN SIZE DISTRIBUTION
PROJECT NUMBER 92347{/001
Prc.'ECT NAME 5620 CR 342
PRo.TECT LOCATTON êilr, CO
CLIENT Sarah Moon
U.S. S¡EVE OPËNll.¡G lN ll,¡CHES6 4 3 21.5 134
U-S- SIEVE NIJfrIBERS I6 810 1416 20 3n ¡tt} 5060 1m140200
HYDROMETER
J
100
95
90
85
80
t-
:E(5
ü
=m
É.tIlz
LL
È-ztuo
É.u¡
o_
75
70
65
60
55
50
45
4A
35
30
25
20
15
10
5
0
100 10 1
GRAIN SIZE IN MILLIMETERS
o.01 0.001
COBBLES GRAVEL SAND SILT OR CLAYcoarsefinecoarsemediumfine
II
I
I .À
{I
il
\\\il
I )\
'l.'il
t:\il\ì
q ilil\\t lil
I Lll\\l\tl
IfI'
'i I
\tr
{
\I il
Y
Specimen ldentification Classification LL PL PI Cc Cu
o TP-1, GB-t 9t24 CLAYEYSAND{SC}32 28 12
E TP-2, GB-1 9t24 GLAYEYSAND(SC)27 17 t0
A TP4, GB-t 9t24 SANDY LEAN CI-AY(CL)28 2A 8
Specimen ldentification D100 D60 D30 D10 %Gravel o/oSand %S¡It o/oC
a 12.5 0.69TP-í, GB-1 9t24 2.9 54.4 42.6
tr TP-z, GB-1 9t24 12.5 1.181 2.6 66.8 30.5
A TP4, GB-î 9t24 9.5 o.2 32.9 66.9
N
o
F.zo
ùo
Õ¡
tooNo
ÌrJNø
Huddleston-Bary Engineering & Testing LI-C
2789 Riverside Parkway
Grand Junction, CO 81501
970-255-8005
ATTERBERG LIMITS' RESULTS
PRT'ECTNUMBER ÚH7ffi1
PRO.IECT ì¡AME 5620 CR 342
Prc.rECT LOCAïOi¡ Snt, CO
CLIENT Sarah Moon
60
P
L
A
Sï
I
c
I
T
I
N
D
E
X
40
30
20
a,|
CL.ML @ @
0
80
LIOUID LIMIT
Specimen ldentifTcation LL PL PI #200 Classification
a TP-1, GB-1 gt24 32 20 12 43 cr-AYEYSAND(SC)
a TP-2, GB-î 9t24 27 17 f0 3l cr-AYEYSANÐ(SCI
A TP4, GB-1 9t24 28 20 I 67 SANDYLEAN CLAY(GL)
(t)
l
Fz(,
o-q
N
vooN
0
oÍtilúEtx
MOISTURE.DENSITY RELATIONSHIP
PROJECT NUMBER O7347-00p1
PRO.IECT T{AME 5ã2l]CR342
PRO.'ECT 1.('MTþN sitr co
CLIENT Sarah Moon
97G255-8005
Junctior,CO 81501
Huddleston-Berry Engineering & Testing LI,C
2789 Riverside Parkway
\)ul
\\
\I \
\
\
\\
\
\
\
\
I
\
\
\
\
\
.4/\\
/\I
t \\
I \
1 \
\
I
\
\
\
\
\
\
145
144
135
130
125
115
110
105
100
90
9n4/2421
214752
TP-I, GB.î
cr-AYEYSAND{SC)
Test Method ASTM D698A
TEST RESULTS
Maximum Dry Density 118-5 PCF
Optimum Water Content 12-5 olo
Sample Date:
Sample No.:
Source of Material:
Description of Material:
15
GRADAAON RESULTS (% PASSTNG)
#2AA H y4',
¡t3 g7 100
ATTERBERG LIMITS
P1
12
PL
20
LL
32
2A1
(J
t!-
(t)zt¡lo
Éo
o
t-ô(9
ni
5(t3
z
o
ù(,
ô¡
tOoN@0
ð
N
No
95
Curves of 100o/o Saturation
for Specific Gravity Equalto:
2.80
2.74
2.60
50 10
ì^/ÀTtrÞ nñÀITtrt\lT q/^
20 25 30
MOISTURE-DENSITY RELATIONSHIP
PROJECT NUMBER V&7ffi1 PRO.'ECT LOCATION Si'T, CO
Prc.'ECf Í{AME ß2lJcR34?CUENT Sarah Moon
970-255-8005
Junction, CO 81501
Huddleston-Berry Engineering & Testing LLC
2789 Rirerside Parkway
,l \'I
\
I
I
\
\\
\
\
\
I
\
\
\
\
-/I
-/\\\
\\
\
I
\
\
\
\
\
\\
\
\
Sample Date:
Sample No-:
Source of Material:
Description of Material:
15
Curves of 100% Saturation
for Specific Gravity Equal to
2_80
2.74
2.60
9t24t2021
214753
145
140
13s
130
125
115
110
105
100
90
TP4. GB.I
SANDY LEAN GI-AY{CL}
Test Method:ASTM D698A
TEST RESULTS
Maximum Dry DensÍty 116.5 FCF
Optimum Water Content 14-0 %
GRADA-IION RESULTS (% PASS|NG)
#200 H 3t4"
67 100 t00
ATTERBERG LIMITTì
PI
I
PL
2A
LL
28
201
()a-tF
q)
z.t¡lâ
v.ô
U'l
t--z
L(9
ô¡
É.Oo
E
oa
ts
No
95
50 10
t^/ÀTtrF¡ nt.lÀrrtrNT q¿,
2A 25 30
APPENDIX C
Percolation Testing Data
PERCOLATION TESTING
sTP322Huddleston-Berry
Enginccrirrg ñ Tcrting, LLC
Project Name:5620 CR 342 Location: Silt, CO
Testing Conducted By:
Supervising Engineer:
S. Dinterman
M. Berry
TEST PIT DIMENS¡ONS
SOIL PROFILE
Test Number'. 1
Top of Hole Depth: 3 (ft)
Diameter of Hole: 4 (in)
Depth of Hole: 18 (in)
TÍme
(min.)
Water
Depth
{in.)
Change
(in.)
0 1.125
à 3.5 2375
10 575 2.25
15 75 175
20 8.75 1.25
25 9,75 1
30 10.75 1
35 11.5 0.75
40 12 0.5
45 12.5 0.5
50 13 0.5
55 13-25 o.25
60 13.5 4.25
2ARate (min/in):
Test Number'. 1
Top of Hole Depth: 6 (ft)
Diameter of Hole: a (in)
Depth of Hole: 7(¡n)
Test Number: _
Top of Hote Depth:
-(ft)Diameter of Hole: _(in)
Depth of Hole: _(in)
02347-0001
TP-2
9t24t2021
Project No.
Test Pit No.
Date:
Length
(ft)
width
(ft)
Depth
(fr)
Water Level Depth (fi)
Depth (ft)Not Encountered
6 X
Depth
(ft)Dæcription Remarks
0-1 Siltv Sand with Oroanics {TOPSOIL}
1-6 Clavev SAND with some Gravels {SC). tan. moist. dense
Time
{min,)
Water
Depth
(in.l
Change
lin.)
0 û.5
5 1 0.5
10 1.125 0.125
15 1.25 at25
20 1.5 0.25
25 1.75 0.25
30 2 0.25
35 2.125 0.125
4A 2.25 o 125
45 2.5 0.25
50 2.75 o.25
55 3 0.25
60 3.125 0.125
27
Time
(min.)
Water
Depth
{in.)
Change
{in.}
r
Average Percolation Rate (miniin):
Rate (min/in):Rate (miniin):
fluddleston-Berry
Enliinrcri¡¡g & Tcrtirig, f-LC:
PERCOLATION TESTING
sTP322
Project Name 5620 CR 342 Location: Silt, CO
Testing Conducted By
Supervising Engineer:
S. Dinterman
M. Berry
TEST PIT DIMENSIONS
SOIL PROFILE
Test Number. 1
Top of Hole Depth: 3 (ft)
Diameter of Hole: 4 (in)
Depth of Hole: 19 (in)
Rate (min/in):
Test Number: _
Top of Hole Depth: (ft)
Diameter of Hole: _(in)
Depth of Hole: _(¡n)
Test Number:
Top of Hole Depth: (ft)
Diameter of Hole: _(in)
Depth of Hote:
-(in)
02347-0001
TP-3
912412021
Project No.
Test Pit No.
Date:
Length
(ft)
width
(fr)
DeÉh
(ft)
Water Level Depth (fr)
Depth (fr)Not Encountered
3 X
Depth
(ft)Description Remarks
0-1 Siltv Sand with Oroanics {TOPSOIL}
1-3 Clavev SAND (sc), tan, moist, dense
Time
(min.l
Water
Depth
f in.)
Change
lin.)
0 4.75
5 5 4.25
10 8 125 3 125
15 10 1.875
20 11.5 1.5
âà 13 1.5
30 13.75 o.75
35 14.75 1
40 15.25 0.5
45 15.75 0.5
50 Drv
10
I
Time
lmin.)
Water
Depth
lin.)
Change
lin. )
I
Time
(min.)
Water
Depth
(in.)
Change
(in. )
I
Average Percolation Rate {min/in):
Rate (min/in):Rate (min/in):
PERCOLATION TESTING
sTP322Huddleston-Berr:y
Engi¡rccrirg 6{ Tc!ting, L¡-C
Project Name:5620 CR 342 Location: Silt, CO
Testing Conducted By:
Supervising Engineer:
S. Dinterman
M. Berry
TEST PIT DIMENSIONS
SOIL PROFILE
Test Number: 1
Top of Hole Depth: 3 (ft)
Diameter of Hole: 4 (in)
Depth of Hole. 17 (in)
Time
lmin.)
Water
Depth
f in.)
Change
(in. )
0 1
5 3.125 2.125
10 4 0 875
15 5 1
20 o 1
25 7 1
30 775 075
35 9.5 1.75
40 10.25 0.75
45 11 0.75
50 11.5 0.5
55 1225 0.75
60 13 0.75
7Rate (min/in):
Test Number. _
Top of Hole Depth: (ft)
Diameter of Hole: _(in)
Depth of Hole: _{in)
Test Number:
Top of Hole Depth: (ft)
Diameter of Hole: _(in)
Depth of Hole: (¡n)
02347-0001
TP-5w
Project No.
Test Pit No.
Date:
Length
(fr)
width
(fr)
Depth
(ft)
Water Level Depth (ft)
Depth (fr)Not Enæuntered
7 X
Depth
(fr)Description Remarks
0-1 Siltv Sand with Oroanics (TOPSOILI
1-7 Sandv Lean CLAY {cl), brown. moist, stiff
Time
lmin.)
Water
Depth
(in.l
Change
(in.)
Time
(min.)
Water
Depth
{in.)
Change
(in. )
r
Average Percolation Rate (min/in):
Rate (min/in):Rate (min/ín)
PERCOLATION TESTING
STP322fluddleston-Berry
Enginccri¡g ñ Tcslit¡g, ¡-LC
Project Name:5620 CR 342 Location: S¡lt, CO
Testing Conducted By:
Supervising Engineer:
S. Dinterman
M. Berry
TEST PIT DIMENSIONS
SOIL PROFILE
Test Number'. 1
Top of Hole Depth: 3 (ft)
Diameter of Hole: 4 (in)
Depth of Hole: 18 (in)
Time
(min.)
Water
Depth
{in.)
Change
(in.)
0 0.5
E 2.5 2
10 4.25 1.75
15 6 1.75
20 7 1
25 I 1
30 8.75 0.75
35 9,5 0.75
40 1A.125 0,625
45 10.75 0 625
50 11.5 0.75
55 12 0.5
60 12.5 0,5
10Rate (min/in):
Test Number'. _
Top of Hole Depth: (ft)
Diameter of Hole: _(in)
Depth of Hole: _{in)
Test Number: _
Top of Hole Depth. (ft)
Diameter of Hole: _(in)
Depth of Hole: _(in)
02347-0001
TP-6
9t24t2021
Project No.
Test Pit No.
Date:
Water Level Depth (fi)
Depth {ft)Not Encountered
Length
(fi)
width
(fr)
De$h
(ft)
X3I
Depth
(ft)Descriptien Remarks
0-1 Siltv Sand with Orqanics ITOPSOIL)
1-3 Sandv Lean CLAY fcl). brown. moist, stiff
ïime
(min.)
Water
Depth
lin.)
Change
(in. )
Change
lin.)
Time
{min.)
Water
De$h
{in.)
I
Average Percolation Rate (min/in):
Rate (min/in).Rate (minlin):