HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 5240 County Road 259Silt, CO 81652 Parcel No.: 212734200159
Owner Name: Jeffery K. Huber and Angela F. Worthen Owner Phone: (970) 401-3700
Designed By: Sopris Engineering, LLC. Designer Phone: (970) 704-0311
Contractor: Owner Contractor Phone: (970) 401-3700
Number of Bedrooms _4__Minimum Tank Capacity __1,250_gal__Minimum Absorption_661.5 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7421________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 04/25/2022 Expiration Date 04/25/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by Sopris
Engineering, LLC. dated March 23, 2022. Changes must be approved by Garfield County Public Health
and the designer prior to construction.
The new OWTS will serve an existing four-bedroom residence. The system will consist of a new, two-
compartment 1,500-gallon septic tank set level with access to grade followed by a 500-gallon single-
chamber pump chamber set level with access to grade and a siphon in the pump chamber. The
existing septic tank and STA will be abandoned in place. Effluent will be pressure-dosed to a
distribution box set level with access to grade that will distribute effluent to 672 ft2 of STA. The new
STA will consist of four gravelless chamber trenches consisting of 9 chambers per trench and two
gravelless chamber trenches consisting of 10 chambers per trench (56 chambers total). Inspection
ports are to be installed at each end of each trench. Maintain all setbacks and elevations as
designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
04/25/2022
Issued By: Garfield County Environmental Health
Department
Date