Loading...
HomeMy WebLinkAboutComponent Specs.Item # lM-1530-2GP l53O Gallon Two Gompartment lnfiltrator@ Poly Tank RECEIVED MAY ll 5 ?û?-3 GARFIELD COUNTY COMMUNITY DEVELOPINENT TANK TOP HALF CONTINUOUS ELASTOMETRIC 175.6'TANK INTERIOR SEAM CLIP (86)TOP VIEW Atlcl.ltr,CNT DOWEL(18)TANK BOTTOM HALF 24" ACCESS PORT TanRlndudetsilds wrTH LOCKTNG LrD (3)@ n¡ro-nerenr sEAM sEcroN DETATL OUTLET TEE 2I3 TOTAL VOL Ii3 TOTAL VOL SIDE VIEW SEAM CLIP ' Compliont with CSA ond IAPMO Stondordsr PVC risers ovoiloble¡ Secondory sofety screen ovoiloble with PVC riser¡ Moximum buriol depth is 48"o Minumum buriol depth is 6"o Tonk is not roted for vehiculor troffic looding¡ Exterior of monhole cover includes the following worning: "DANGER DO NOT ENTER: POISON GASES" LIFTING STRAP (fYHC,qL) END VIEW {ffi FILTRATOR' s€ptlc lanks ¡älr^fotsvsaßlE Digging Specs ln vert Dimensions Net Workin width 61.7" o o €o-t o o € o é o o ÈrOÊ FIBERGLASS SUPPORT I r SLOT 16' Long x 7' Wide 43" below inlet lnlet 47" Outlet 44" Length 175.6" p. 501 lbs.1006 gol Height 54.5" Net Weight 503 gol 1509 gol Water & Wasûeulaûer o Sllstems ¡ Prcducrts InG. o Servlce (719) 39567G4 ãXFOo' Rd3l7 P.O. Bo(æ5 Fax (t19)ggæ727 BrilaMs4 @81211 lVebalb: www.vallolryr€cast@rr Emall : fonüæk@valle¡¡precast ænrE PRTCASI, Double Walled PVG Riser & L¡d Options Poly Lid (Static load tested to 5000lbs)¡ Skid resistiance surfiace¡ Available in grêenr Highest level of UV Protection included¡ lncludes a foam gasket for airtight and watertight appl ications¡ lncludes square drive screws to discounage unauthorized enfyo Insulation panels achieve R-10 insulation rating 2'ot Standard Orenco @ DuraFiberm Access Lids (FLD) Not recommended for vehicular haffic 24' and 30" Diameterso Solid,resin-infusedfiberglassoonstt¡ctiono 20,00G1b breaking shengitho Standard green or brown colos¡ Available with orwithout urethane lid gasket¡ Available with caröon filhationo 4 stainless steel flathead socket cap screws & hex keywrench¡ Insulated lids availablo-2'o¡4' Double Walled PVC Riser . Available in24" and 30'Diameter¡ Cut to lengür¡ Sold in +/- 2' incremenß¡ Must be cut between ribs Ø PRTCASI, Water & Wasüewaüer ¡ Systems ¡ Prcducts fnc. o Servlce Frg) 395€764 2flXFOo' Rd' 317 P.O. Bo(æ5 Fax (71g)ggfigm B'm\ßûa, @81z-1 Webslb: wwwvalle¡ryrecastæm Emall : fronHesk@valle¡ryrecastæm Resident al B¡otube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranry. They prevent large solids from leaving the tank, dramatically improving wastewater qualiry and extending the life of residential draintelds. 4-in. (100-mm) Biotube Effluent Filter 4-in. (1 00-mm) Biotube Jr. (4-in. Biotube cartridge auail- able separateþ as Insert Fiber) I , B-in. (200-mm) Base Inlet Fiber 4-in. (100-mm) Insert Fiber * : t l ? ', 7 í ? ? t t:. ,1a : ,.: Orenco's superior efrluent fihers resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Fiher prouides maximum long-term protection in a complete package, uith housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard model, has more fibering capacity than the full-sized filærs sold by other manufacturers. For tanþs with existing outlet tees, the Biotube Insert Fiber is ideal. And þr low-profle tanþs, tltere's the Base Inlet Fiher. * Covered by patenr ¡umbers 5,492,635 a¡d 4,439,323 To Order Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS-Ff-1 Rev. 3.4 O 11/10 0renco Systems@, lnc. Standard Features & Benefits . Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal . Easyto clean by simply hosing off whenever the tank needs pumping . Removes about two-thirds of sus- pended solids, on average, extendlng drainfield life . Corrosion-proof construct¡on, to ensure long life . Lifetime warranty 0ptional Features & Benefits Biotube Filtering Process . Alarm available, to signal the need for clea ning . Flow modulating discharge orifices ava¡lable to limit flow rate leaving tank, mitigat- ing surges and increasing retention time . Custom and commercial sizes available Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the B¡otube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. ^-) Changing tlx Vlag the 'W'o r ld D o e¡ tYa ¡ r t w d t e r"' www'otënco,com ñ1.ffi Orenco Systems* lncorporaled Carlridge height: 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W = fits ïype 3034 outlet pipe S = fitsSchedule 40 outlet pipe 8-in. Biotube Filter {base intetmodel) FT 0822-14 B Nomenclatures 4-in. Biotube Filter (standard) FT 04 FTJ Ino¿ rs 0ptions: Blank = no optionsM = flow modulation plate inslalledA = float bracket attached 0ptions:A = float bracket FS = 2" outlet orifice FSo = 2"outletor¡ficeandoverflowplate* 4-in. Biotube Effluent Filter Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube@ filter cartridge Solid Filter housing 4-in. Biotube Jr. Tank wall 1/S" filtration 1/1 6" f¡ltrat¡on Blank P Biotube effluent filter ser¡es Riser wall Base inlet model Cartridge height: 1 4" standard Housing height: 22" standard F¡lter diameter (inches) 08=8" Blank = l/8" filtrationP = .l/16" fi¡tration Biotube effluent f¡lter ser¡es . Also available with coupling and sleeve as a "kit": FI-OVERFLoWKIT 4-in. Biotube Jf. (includes cartridge and housing) Filter diameter (inches) W = fits Type 3034 outlet teeS = fits Schedule 40 outlet tee Blank = 1/8" filtrationP = 1/16" filtration Junior ser¡es Biotube effluenl f¡lter series 4-in. Biotube Fiher lnsert (carridse onty) FT¡0418- 0ptions: Blank = no optionsM = flow modulat¡on plate ìnstalledA = float bracket attached Cartridge height (inches) For customized options (e.9., NC indicates North Carolina regions) W = fitsïype 3034 outlettee S = fits Schedule 40 outlet tee Cartridge height (inches) Filter diameter (inches) Blank = l/S" filtrationP = 1/16" filtration lnsert Biotube effluent filter series Distributed By: POLYLOK DISTRIBUTION BOX, RISERS, AND LTD UD-BOX6&UDAOXS --22.45'u D-BOX SEAL (ErrERYDt))(Of¡ilEgWIH asE ra) 16"SIDE CUT OUT TO ACCEPT POLYLOK SEAL NO.3001 TEAR OUT FOR 4" SDR-35 OR scHD-40 NOT TO SCALE UD.BOX 6" RTSER ROTO-FLOW 4'lþ i UD.BOX 12'RISER NOT TO SCALE POLYLOCK EQUAUZER 'v-NoTcH'llyElR 1 SHAFE lS gE..F TEVELII{G RIBS PROVIDE Fff FORATI.'' PIPE ID 20'COVER FOR RISER &D.BOX ^rorrosGArE GASKETED SEAL ON LID & RISER l Water & Wastewater o Systems o Products InG. o Servlce Frg) 3956704 2tþ5co Rd3l7 P.O. Bo(gA5 Farc ft19)gg+g\n Bt¡sE\nsa' @812,l.1 Webslte: www.valle¡ryrccastæm Emll : fronüesk@wlle¡ryrecast æmØ PRECASI, . ," ".:-).:. ,'r Trtig,*##.,,,, The Ouick4'Plus Standard ChamberIN FILTRATOR' '¿ç=is-ær4"-*r:Yz**â*æí*'¿ The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection" which permits turns up to 1S-degrees, right or left. lt is also available in four-foot lengths to provide optimal installation flexibility The Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength /hQuick4 Plus" series Ouick4 Plus Standard Chamber Benefits: . Two center structural columns offer increased stability and superior strength . Advanced contouring connections . Latching mechanism allows for quick installation . Four-foot chamber lengths are easy to handle and install . Supports wheel loads of 16,000 lbs/axle with 12" of cover Quick4 Plus All-in-0ne 12 Endcap Benefits: . May be used at the end of chamber row for an inleVoutlet or can be installed mid{rench . Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows . Center-feed connection allows for easy installation of serial distribution systems . Pipe connection options include sides, ends or top Ouick4 Plus All-in-One Periscope Benefits: . Allows for raised invert installations . 180" directional inletting . 12" raised invert is ideal for serial applications Certified by the lnternational Association of Plumbing and Mechanical Officials (IAPMO) Size 34"Wx53"Lx12"H (864 mm x 1346 mm x 305 mm) Etfective Length 48" (1219 mm) Louver Height 8" (203 mm) Storage Capacity 47 gat (178 L) lnvert Height 0.6" (15 mm),5.3" (135 mm), 8.0" (203 mm),12.7" (323 mm) Quick4 Plus Standard Chamber Specifications APPROVED in w Quick4 Plus" Series =0ui,G*4-*" Ouick4 Plus Standard Ghamber 12', 34 48', EFFECTIVE LENGTH Ouick4 Plus All-in-One 12 Endcap PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) FRONT VIEW '18" 8" INVERT SIDE VIEW INFILTRATOB WATER TECHNOLOGIES STANDARD LIMITED WARBANTY (a) The structural integrity of each chamber, endcap and other accessory manufactured by lnfiltrator ("Units"), when installed and operated in a leachfield of an onsite sepiic system in accordance with lnfillrator's instructions, is warranted to the orig¡nal purchaser ("Holder") against defect¡ve materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installat¡on of the septic system commences. To exercise its waranty rights, Holder must notify lnf¡ltrator in wr¡ting at ¡ts Corporate Headquarters in Old Saybrook, Connecticut w¡thin fifteen (15) days of the alleged defect. lnf¡ltrator will supply replacement Un¡ts for Units determined by lnfi¡trator to be covered by this Limited Warranty. lnfilkator's ìiability specifically excludes the cost of removal and/or installation of the Units. (b) THE LIMITED WARHANTY AND REMEDIES lN SUBPARAGBAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WABBANTIES OF MERCHANTABILITY OH FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than lnfiltrator. The Limited Waffanty does not extend to incidental, consequential, special or indirect damages. lnfiltr.ator shall not be liable for penalties or liquidated damagês, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any th¡rd party. Specifically exc¡uded from Limited Warranty coverage are damage to the Un¡ts due to ordinary wear and tear, alteration, acc¡dent, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installat¡on instructions; fa¡lure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper mater¡als into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, jmproper grease disposal, or improper operat¡on; or any olher event not caused by lnfiltrator. Th¡s Limiled WarranÇ shall be void if the Holder fails to comply with ali of the terms set forth in this Limited Warranty. Further, in no event shall lnfiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from instal¡ation or shipment, or from any product liability claims of Holder or any third party. For this Limited Wananty to apply, the Units must bo instâlled in accordance w¡th all site cond¡tions required by state and local codes; all other applicable laws; and lnfiltrator's installation instruct¡ons. (d) No representative of lnf¡ltrator has the authority to change or extend this Limited Warranty. No wârranty applies to any party other than the original Holder. The above represents the Standard Limited Wananty offered by lnf¡ltrator. A ¡imited number of states and counties have different wananty requirements. Any purchaser of Units should contaÕt lnf¡ltrator's Corporate Headquarters in Old Saybrook, Connecticut, priorto such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty pr¡or to the purchase of Units. Quick4 Plus All-in-One Per¡scope QUICK4 PLUS ALL-IN-ONE PERISCOPE (360. SWTVEL) 12.7" INVERT ls"l I IN FILTRATOR' 4 Business Park Fìoad P.O. Box 768 Old Saybrook, CT 06475 860-577-7000' Fax 860-577 -7001 'l-aoo-221-4436 ..'.1't,.,,'..-...-r 'eas a*.*f Èø*içzfw*rsr¿i*ç www.inf i llratorwater.com Contour, Microleaching, PolyTutf, Chamberspacer, Mult¡Port, PosiLæk, Quickout, Qu¡ckPlay, Snaplock and Straightlock are lrademarks of lnf¡ltrator WaterTechnologiæ. Polylok is a trademark ol PolyLok, lnc. TUF-TITE is a reg¡stered trademark of TUF-TITE, ¡NC. Ultra-F¡b is a ùademark of lPËX lnc. @ 2013 lnfiltratorwaterTæhnologies, LLC. All rights reserued. Printed ¡n U.S.A. PLUSos 0713 /\7 Contact lnfiltrator Water Technologies' Technical Services Department for ass¡stance aI1-800-221-4436