HomeMy WebLinkAboutOWTS DesignSite & Soil Evaluation 893 County Road #L02 BU I Project No. 22O22.O'J. Deric J. Walter, PE #37LLO Date:April 29,2022 SITE EVALUATION SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DEfrIC J. WALTER, PE DNVIEL [. HAßûIN, PE B()UNDAßIESUNUfiTITED INC, KUMAN&ASSOCIATES,INC. 92s C0]PER AVE.,STE.20t 5020 C.8.#154 GLEM|OOD SPßINGS, CO 81601 GLENWÚOD SPHNGS. CA BI6OI 970.945.5252 970.945.7988 EVALUATI0N DATE(S): JUNE 2021 ANO MARCH 2û22. SETBACK REourREMENrs FOR A@ElIgELlsTA TRFNTH/BED, UNLTNED SAND FILTER 0R SEEPAGE PIT {PER ïABLE 7-1 ) AND AN ADWF= 1 21 5 GPD: 3.4, SPRING,WELL0RP0TABLECISTERN=1183.8. P0TABLEWATERSUPPLYLINE:43' 3.C. STRUCTUREWBASEMENT/CRAWLSPACE=2û' 3.D. STRUCTIJRE W0 BASEMENI/GRAWL SPACE:10' 3.E. PR0PERIY LINE, PIPE 0R LINFD IRRIGAII0N DITCH=1 0' 3.F. INTERMITI'ENTIRRIGATI0N LATERAL, INFILTRATIONSTRUCTURE=25' 3.G. LAKE, POND, WATER ü0URSE, IRRIGATI0N DITCH, STREAM 0RWETLAND=68'3.t1. DRY GULCH, CUT BANK 0R FILL AREA:Z5' 3.1, SEPTIC TANK=5' 3.J. RESTRICïIVE LAYER 0R GR0UNDWATER (VERIICAL): 4' {ïREAïMENï LEVEL 1, GRAVITY FEED) 3. SETBACK REOUIREMENTS FOR ÏHE SEPTIC TANK SHALL BE (PER TABLE 7.1 ):3.4. SPRING, WEIL 0R P0TABLE CISTERN=S0' 3,8. P0TABLE WATER SUPPLY LINE=1ü'3.C. SIRUCTURE Wl BASEMENT/CRAWL SPACE=5' 3.D. STRU0IUREW0BASEMENT/CRAWLSPACE=5' 3.8. PR0PERTYLINE. PIPE 0R LINED IRRIGAI0N DIICH=10' 3.F. INTERMITTENTIRRIGATION LATERAL, INFILTRATI0NSTRUCTURE=10'3.G. LAKE, POND, WATER COURSE. IRRIGATION DITCH, STREAM 0R WEILAND:50' 3.H. DRY GULCH, CUï BANK 0R FILL AREA=1 0' 3.1. STAIRENCH/BED, UNLINED SAND FILIER 0R SEEPAGE PIT=5' Figure 7:Soìl Evqluotion the Civil Engineering Su¡r.eying SOIL EVALUATION 1. SO¡L WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER AS USDA SANDY LOAM, LOAM, SILT LOAM TYPE 2A AND AN LTAR OF O.5O GPD/SF AND CONFIRMED TT BE SIMILAR BY BOUNDARIES UNLIMITED INC. WIH ADDITIONAL TEST PITS 120 e 340'WESï (DOWNHTLU 0F THF KUMAR TEST Pt-r-S THE NAIIVE SOILS MAY CONTAIN BOULDERS. IF ENçOUNTERED, REMOVED THE BOULDER AND BACKFILL THE VOID WTH LOAMY SAND OR SANDY GRAVELS. ,1 B" SURFACE Srte & Soils Evaluation .9cale: N IS. I 3. r I T 9â3{ooperAvenue, Ste.l0l I Glenwood Springs, CO 81601 | 97A.945.5252 | www.bu-inc.com Septic Area: Two profile pits were dug at the locations shown on Figure 1. The soils exposed in the Profile Pits shown on Figure 2 consist of I foot of tcpsoil overlying 3'/z feet of loam over 4t/z feef of silt loam down to the bottom of the pits at 9 feet. Both soils are considered soil Type 2A per Colorado Department of Public Llealth Guidelines. Based on the subsudace conditions encountered, the area of Profile Pits I and 2 should be suitable for a conventional infiltration septic disposal system. A civil engineer should design the infiltration septic disposal system. FÍgure 2: Soils Description from Kumar & Assoc. Project No. 27-7-392, dated June 7, 2027 -? r\l 'iL é)"(Prf ^S ps é' lrsl, ',tll LOCAl¡0liS Figure 3:Pit locot¡ons 923(ooperAvenue, Ste" 201 | Glenwood Springs, CO 81601 | 970.945.5252 | www.bu-inc.com Figure :Soils Observotion-New Location 720'West Figure 5: Soils Observotion-New Locotion 720'West . -*. j; r" I r I 'Í- --'' . :: . .. t' rti Figure 6:Soils Observation-New Locqtion 340'West Figure 7: Soils Observqtion-New Locotion 340'West . ) ) ]t:: i,,,,t.tt. 1, 1.: ; i