March 28,2022 Project No. C1700
Stig Svedberg
ssved berq(Acomcast. net
Subsurface lnvestigation and Onsite Wastewater Treatment System Design
2-Bedroom Residence
277 JB Court
Garfield County, Colorado
Stig,
CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 2.766-acre property is located outside of Glenwood
Springs, in an area where OWTSs and wells are necessary.
Legal Description: Quarter: SW Section: 25 Township: 5 Range: 90 A TR CONT 2.50 AC, ALSO A TR
CONT. .22 AC. ALSO A TRACT OF LAND CONT. .046 AC.+/- AS DESC. IN RECEPTION # 858415.
Parcel lD: 2123-253-00-046
SITE CONDITIONS
There are two residences developed on the property: a 2-bedroom residence and a 1-bedroom cabin.
Both are served by separate existing OWTSs. We were unable to find any documentation from Garfield
County on either OWTS. lt should be noted that the Garfield County Assessor's website notes the 2-
bedroom residence was built in 1969 and the 1-bedroom cabin in 1971 .
The subject OWTS serving the 2-bedroom residence is slow draining and there is a desire to upgrade the
system. The 1-bedroom cabin will continue to be served by the existing, OWTS'
Potable water on the property is served by an existing well. The well ís located to the south of the 2-
bedroom residence. The well is located within the 50-foot setback to the existing OW[S.
Canyon Creek runs to the west of the residences within the western property boundary. The existing
OW|S is located within the 5O-foot setback to the creek. With the proposed septic tank location within
the S0-foot setback to both the creek and the well, it is recommended that a bitumastic coating be applied
to the outside of the septic tank or a liner incorporated in the septic tank excavation, bedded with sand or
pea gravel (or non-angular rock).
Garfield County On-Site Wastewater Treatment System Regulations, Table 7-1, Note: states "For repair
or upgrading of existing OWTS where the size of lot precludes adherence to these drsfances, a repaired
OWTS must not be closer to setback features than the existing OWT9, as reviewed and approved by the
local public health agency."
There is also an irrigation and ditch and pond that is filled with irrigation water during the summer
months. The proposed STA will be located at least 50-feet from the irrigation ditch and pond. lt should
be noted that the pond may require mitigatlon to assure there is no over.flow when it is full as the
Page2
proposed STA is downgradient of the pond and there is evidence that over-flow has occurred in
the past.
Photo of pond
We do not find it feasible to locate the proposed septic tank outside of the required setbacks required for
the well and the creek. The proposed soil treatment area (STA) will be located to the east of the
resídences, outsíde of required setbacks. The proposed STA focatíon has an approxímate five percent
slope to the west toward Canyon Creek. The proposed area is vegetated with native grasses.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
SUBSURFACE
The subsurface was investigated on March 16,2022 by digging two soil profile test pit excavations (Test
Pits). A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.l
The materials encountered in Test Pit #1 consisted of dark brown topsoil to 2.5-feet, underlain by medium
brown to silty clay loam a maximum depth explored of 6.0-feet with increasing density below 5.5-feet. No
bedrock or groundwater was encountered.
The materials encountered in Test Pit #2 consisted of dark brown topsoil to 2.5-feet, underlain by medium
brown to silty clay loam a maximum depth explored of 7.0-feet with increasing density below 6.5-feet. No
bedrock or groundwater was encountered.
A sample of the soil was taken from Test Pit #1 at 3-feet below grade. The soil formed a ball and a
ribbon 1 to 2-inches in length before breaking. Soil structure shape was blocky and consistence was firm
to extremely firm. Soiltexture was more smooth than gritty. Soilstructure grade was moderate,
becoming more dense with depth. A shallow (approx. 2-feet below native grade) installation of the STA
is proposed.
STA sizing is based on SoilType 3, Silty Clay Loam with moderate structure grade. A long term
acceptance rate (LTAR) of 0.35 gallons per square foot will be used to design the OWTS.
'Carla Ostberg holds a Certificate of Attendance and Examination from the CPOWVisualand Tactile
Evaluation of Soils Training.
Page 3
t .'4. -
Test Pit #1
¡j
tt
¡d 'y
Sieved sample
*
Ribbon length
Page 4
Test Pit #2
View of Test Pit #2 looking toward Test Pit #l (looking south)
DESIGN SPECIFICATIONS
The existing OWTS serving the 1-bedroom cabin will remain. The existing septic tank serving the 2'
bedroom residence will be pumped and the top, bottom, and sides crushed, and remaining void filled with
onsite material or removed. The existing STA will be abandoned in place.
Desiqn Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD
LTAR = 0.35 GPD/SF
300 GPD / 0.35 GPD/SF x 1.0 (pressured dosed bed) x 0.7 (chambers) = 5gg ga
The new OWTS design is based on 2-bedrooms. An average daily wastewater flow of 300 GPD will be
used.
: i:li
'l
Page 5
For the purposes of this OWTS design, Benchmark Elevation has been established as 100' as the
elevation of the existing sewer line exiting the residence. CBO lnc. should be notified of any
discrepancies or problems with grade elevations of proposed components during installation of the
OWTS.
*Elevations are based upon standard OWTS installation practices Component may change during
installation due to site conditions. Minimum grade refers to piping between components.
The sewer line exiting the residence must have a double-sweep clean out and a minimum 2% grade to
the septic tank. This sewer line must also be encased as it comes within 50-feet from the existing well
(See Encasement Detail W4.0i3).
The system installation will include a 1O0O-gallon, two-compartment Valley Precast concrete septic tank
wíth an Orenco@ Bíotube Pump Vault and an Orenc@ PF3005 pump in the second compartment of the
septic tank. lf the septic tank will be in an area subiect to traffic, it must be traffic rated. The floats
should be set to dose approximately 80 gallons each pump cycle, allowing approximately I gallons of drain
back after each pump cycle. A pump curve is enclosed. The control panel for the pump must be located
within line of sight of the septic tank. We recommend Valley Precast out of Buena Vista be contracted for
start-up of the pumping system.
A 1.S-inch diameter Schedule 40 pump line must be installed from the pump to an Orenco@ automatic
distributing valve (ADV), model 6402. The elevation difference between the components must be
verified to assure the pump curve was run properly (estimated 20-feet elevation difference). This
pump line must have a minimum 1% grade for proper drain back into the tank after each pump cycle. The
pump line that runs under the driveway and within the 50-foot well setback must be encased (See
Encasement Detail W4.0i3). The ADV must be placed at a high point in the system in an insulated riserwith
access from grade. Screened rock must be placed below the ADV to support the ADV and to assure the
clear pipes exiting the ADV remain visible forfuture inspection and maintenance.
Effluent will be pressure dosed through 1.S-inch diameter pipes to a gravelless chamber beds with four
rows of 13 'Quick 4' Standard Plus Low Profile f nfiltrator@ chambers, for a total of 52 chambers and 624
square feet of infiltrative area. The ADV will divide the bed into two zones, each with 2 rows connected
with a level manifold. Effluent will be pressure dosed to 1.S-inch diameter laterals, which must be hung
with zip ties from the underside of the chambers. Laterals will have 5132-inch diameter orifices facing up,
with the exception of the first and last holes facing down for drainage. Orenco@ Orifice Shields may be
placed under each downward-facing orifice. The orifices must be placed 3-feet on center. Ëach lateral
Minimum ElevationOWTS Gomponent
Approximate horizontal distance 46' I min.2D/o fall I
min. 1f .5" fall
Primary Tank lnlet lnvert
Approximate horizontal distance 228' I min.1% rise
/ min. 28.5" rise
Automatic Distributing Valve
Approximate horizontal distance 3' / min. 1o/o Íall I
m1n.0.375" fall
lnfiltrative Surface
Min. 70 gal. (10 gal x 4) + 30 gal
drain back
Max = 105 gal. (300 GPD x25o/o
+ 30 qallons drain back)
Dose Range
80 gallons/dose 30 gallons drain back (288' I 1.5'
diameter pump line)
Dose Setting
12" onlotf float separationFloat Separation 1000 gallon 2-compartmet Valley
Precast concrete septic tank
45.4 feet total dynamic head
ITDH)
24.5 gallons per minute (GPM)Pump Criteria
Page 6
must end in a 90 degree ell facing up w¡th a ball valve for flushing. Valves may be placed in a valve box,
accessible from grade, for access. lnspection ports must be placed at the beginning and end of each
trench. Ports may be cut to grade and covered with a valve box for access.
The STA must be shallow, with burial depth of the chambers not to exceed 2-feet below native
grade.
COMPONENT SPECIFICATIONS
The component manufacturers are typícal of applications used by contractors and engineers in this area
GBO lnc. must approve alternative components prior to installation of the OWïS. Requests must
be submitted, in writing, to our off¡ce for approval prior to installation. Component technical data
sheets are available upon request.
Construction must be according to Garfield County On-Site Wastewater Treatment System Regulations, the
OWTS Permit provided by Garfield County Building Department, and this design.
INSTALLATION CONTRACTOR
CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this ofüce is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours
in advance to observe the installation.
COMPONENT MANUFACTURER MODEL NO.COMMENTS
Septic Tank Valley Precast Item # 1000T-2CP-HH 2-compartment concrete
septic tank with high
r¡ead Þump
Pump Orenco@ PF300511%HP
120 Volt
Biotube ProPak Pump
Packaoe
Orenco@ BPP3ODD /ault, Filter, Control Panel
ldemand dose)
Tank Risers and Lids Orenco@ Double-walled PVC Risers and
Lids (24" diameter)
ADV Orenco@ v64024 1.5" lnlet and Outlets
ADV Riser and Lid Orenco@ Double-walled PVC Risers
and Lids 130" diameter)
Or¡fice Sh¡elds Orenco@ os150 1.5 inch diameter (B total)
Flushing Assembly Orenco(Ð 1.5" diameter (2) 45" or 90" long sweep only
(4 total)
Chambers lnfiltratorG)52'Quick 4' Low Profile
chambers
PageT
ln an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be re$ponsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the oper:ation and maintenance of each OWTS servicíng the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy eguipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to en$ure that no additional water is being discharged to O\^nS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
Page I
LIMITS:
The design is based on information subm¡tted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. AIIOWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requ¡rements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO lnc.Reviewed By:
(læn[a ûrtbuxg
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
388?3
4-25-2022
l t
L
Pump Selection for a Pressurized System - single Family Residence Project
277 JB Court
Parameters
300
Discharge Assembly Size
Transport Lêngth Before Valve
Transport Pipe Class
Transport Line Size
Distribut¡ng Valve Model
Transport Length After Valve
Transport P¡pe Class
Transport Pipe Size
Max Elevatíon Lift
Manifold Length
Man¡fold Pipê Class
Manifold P¡pe Size
Number of Laterals per Cell
Lateral LengÍh
Lateral Pipe Class
Lateral Pipe Size
Orifìce Size
Or¡f¡ce Spacing
Rêsidual Head
Flow Meter
'Add-on' Frict¡on Lossês
Galculations
1.25
288
40
'1.50
6402
3
40
1.50
20
3
4A
1-50
4
52
80
1.50
5132
J
5
None
0
inchês
feet 238r
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
200
150
100
50
PumpData
250
Minimum Flow Rate per Orifice
Number of Oril¡ces per Zone
Tolal Flow Rate per Zone
Number of Laterals per Zone
o/o Flow Differential lsULast Orifice
ïransport Velocity Before Valve
Transport Velocity After Valve
Frictional Head Losses
ool¡
ÄoF.
dt!o
I
.g
E(lt
o
ìã
clÞ
00
4-2 feet
10.4 feet
5.4 feet
0.1 feet
0.0 feet
0.3 feet
0.0 feet
0.0 fe€t
0.68
36
24.5
2
2.4
3_9
3.9
gpm
gpm
fps
lps
Loss through Discharge
Loss in Transport Before Valve
Loss lhrough Válve
Loss in Transport after Valve
Loss in Manlfold
Los6 in Laterals
Loss through Flowmeter
'Add-on Friction Lossês
Pipe Volumes
5 10 15 20 25
Net Discharge (Spm)
30 35 4A
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Latera¡s per Zone
Total Vol Before Valve
Tolal Vol After Valve
30.5
0.3
0.3
9.5
30.5
10.2
gals
gals
gals
gals
gals
gals
PF3005 High Head Efruênt Pump
30 GPM, 1/2HP
115i230V 1Ø 60H2,200V 3ø 60Hz
PF3007 High Head Effuent Pump
30 GPM,3/4HP
23oV 1Ø 60H2,2?ol46ov 3ø 6OHz
PF3010 H¡gh Head Effuent Pump
30 GPM, 1HP
230V 1Ø 6OHz,20O|46OV 3Ø 6OHz
PF3015 High Head Effluenl Pump
30 GPM, 1-1I2HP
23OV 1ø 6OHz,2OO|23O|46OV 3Ø SgHz
u¡rements
gpm
sYsfÉavrs@
l
ì
\
+;
)s l+F \
System Curve: -
Pump Curve:'
Pump Optimal Range:-
Operating Po¡nt:O
o
Design Point:
24.5
45.4 feet
CBo lnc.129 Cains LânêCartondale, Colorado I 1 623Phone 970.309.5259carla.oslberg@gmail.cffiNf{t/.: ûe!1r ., jc i, {l' .¿ e ': ftl1i , - aÙ '')n( ç¿:1'tú. u'rw11g:7:MIN.l4g'514tTP2os75ISCALE: 1 = 50'=0"!STAt\'TP1c\tÐ----! I'5,r-,, >¡. i I2./2 ¡t,.:re..: +,/-t! 3)¡terlIRESIDENCE5:á.itAPPROX,OF CANYON CREEK/f\s€\:\P.O.8. 30'lAccessEdsernentI per ReeNo. J43959//Slf Cor.Sec. 25-5-9ObSEPTICTANK*Y/hNI{ Cor.Sec. 36-5-90at"7.<ç.taIIN\JG1þ\Baszess;TNSit Cor.t28265'Sec. 25-5-9Og a6",38'3.? " tt z?t. AÊDRAWNGS MUST BE USED INCONJUNCTION WII-H DESIGNLETTER DATED 0312812022Iw2.0Svedberg Residence277 JBCovttGarfield County, ColoradoProjectNumber: C1700Date: 031-2812022Designed by: CBOReviewed by: RBDrawnby DDLINEPONDh"It],\,\i\,t1$.\::í (u'r/,:r;..C1eel<,"'r.' t','), ,t),Jð-¿\il;ì1þ1\È-!bTHE LOCATION OF PROPOSED IMPROVEMENTS SHOI\N ARENOT THE RESULI OF A PROPERTY SURVEY. THE LOCATONSARE APPROXIMATÊ. IT IS THE HOMEOWNÊRS' ÐUTY TOENSURE ALL CONSTRUCT]ON AND IMPROVEMENT IOCAIIONSARÊ ACCURATÊ. PROPERTY LINES AND SETBACK DISTANCÊSSHOULD BÊ CONFIRMED PRIOR TO EXCAVATION, SCALEDFOR PRINTING ON t f'X 'I7' PAPER,III,iC"triae Åccessw1 .0Sheet 1 0F 4
'\,-i.i,.1",]P+548575VAL-12'-ellrATVELATERALEACHOFENDMANIFOLDSLËVELPOINTHIGHATæ02MODEL6RADEATACCESSIBLËCRËEKCANYONOFNPROFILELOWOFROWSSHIELDS.ORIFICEWITHCOVEREDDRAINAGEFORDOWNFACING4','outcK62413AN4WITHBEDCHAMBERTOTALAFORCHAMBÊRSoRrFrcEs,ÐtAFEETSOUAREANDCHAMBERSDIAUP.5'FACINGCONNECT52o.cOFSCH-40 SUSPENDED LATERALS. FIRSTAND LAST ORIFICES5t32',TWOWITHTANKSEPTICCABINSERVICINGSTA€:'i',,|1i i:.,iEXISTING/Èrbk,þ;ATBED1PPORTËACHLÊVELscH-40.5"DIAli,"''i!ìOFCORNER\,:\30'-0'SCALE:BEDEACHTOLINErLPUMPPVCSCH40DIA-t(_.TANK)ïoBACK(MrNLOCATIONAPPROX"ì:...o" i:1 i'.,-),/ ,,:l'"a_30t1.5'rl Ðt\ñl- íÍ'I j-:,-.--'aLg\ :--:r/ ?LINE.PUMPscH-40DRAINDIAYodr,,¡ ''l,/ri/\./,2.BEDROOM!..)iua_':'\,,'i,l\.1', t'";:n Resloerucetp- \IOOO-GALLON 2-COMPARTMENT SEPTIC TANK WTH ANoRENCO PUMP PACKAGE tN THE\ECOND COMPARÌMENT,ABANDONEDTONGEXISTIOFLOCATIONPOSSIBLE,ENCASEMENT PIPEWALKWAYUNDERBM*"t"PLACEINABANDONEDWITHPIPESEWERHOUSEFROMLINESEWERREPLACEw4.0/3)(sEEWËLLTHEïSDR.35TOFALLDIA2lo4',MINOFANDRISERS\.1Ç,)-tt\scH-40enMIN.B..9'5INo.P.EaA50'WTHINENCASEANK.SEPÏIC,/,\/$/'/I/l//CCEsemLINEPUMP,7,>vv.iaral' \'-jbCONDUIT50-FOOTTHEWTHINANDDRIVËWAYUNDER\Y//SETBACKWELLGRADETOBEiLIDSTO.1_/^PROPOSED OWTS r\rf--r.=FãiÕ:Ï;\w2.0ooCBO lnc.129 Cains LânêCarbondalê, Colorado 81 623Phme 970.309.5259ærla.ostberg@gmail.comSvedberg Residence277 JB CoudGarff eld County, ColoradoProjectNumbêr: C1700ùate: 0312A12022Drawn þy:by: C8OD€s¡gnodReviewedby: RBDDShæt 2 0F 4
ADV MOOÊL 6402 WTHACCESs AT GRADÉ1.s',DtA SCH-40 PVCDISTRIBUTION LINES FROMADVINFILTRAIOR(R) QUICK4LOW PROFILECHAMBERS,3'X41.5" DIA SCH.4O PVC SUSPENDEOLÀTERÂLS WfiH 5132" ORIFICESFÀCING UP 3'O.C. FIRST ANDLAST ORIFICES FACE DOWN FORDRAINAGE30'DI.AMETER PVCRISERFROMPUMPINGSLIP.ON PVCDO NOT GLUËTRACERWRE4" DIASEWER LINECOMPACT1.5" DIA SCH-40 PUMPLINE FROMSEPTIC TANK1.5' DIA SCH40 PVCLE\IEL MANIFOLD52 CHAMBERSACHAMBER BED PLANLt--rlrENoTË: INSTALLATION MUSI BE SIJALLOW, NOT TO EXCEED 2'BELOW NATIVE GRADE.4" DIA SDR 35 PVCINSPECTON PORTATWITH NATIVÊ Î\4ATËRIALEACH CORNER OF(MUST BE MTNUS 3.|NCH MA'[ER|AL)OR TOPSOIL2',EXTÊNTEXCAVATION/ACHAMBER BED SECIION\3r__-__-TmrG[rDISTRIBUTINGVALVE ASSEMBLYFLUSHING ASSÊMBLYINFILTMTOR(R)ourcK4(TM) rowPROFILE CHAMBER, 3'X4'PORT AT ÊACHCORNER OF SlAEND ÊACH LATERAL IN A 90"SWEEPING ELL FACING UP WTHA BALL VALVE FOR FLUSHINGÞVC ¡NLET ÂNOOUTLETS/I AUTOMATC DISÎRIBUTNG\9r-"-"rrræVALIE DETAIL.5'ÐlA SCH-40FINISHED GRADETO TANK/ICLEANOUT DEÎAIL\J,/--rtûæVALVË WÊRBOX OR IRR¡GAÎONVALVE BOX AI GRADÊCAP OR THREADÊDCLEANOUT ASSÊffiLYPVC PIPÊ CUT TOFll1ìINSPEC]ION PORT IN CHAMBER\9r-""-'-"'-' ñrãE1,5'DIA SCH.4O PVC SUSPENDEÐLAÎERÀLS WTH 5/32 ORIFICESFACING UP 3' O.C. FIRST ANDLAST ORIFICÉS FACE DOWN FORDRAINAGE. SUSPÊND WITH ZIP'TTESBASE TO SUFPORIBOXUSE HOLE SAW ÌOCUT ÍHRU TOP OFENDw3.0ACBO lnc,129 Ca¡ns LaneCarbondále, Cdorado 81623Phone 970.309.5259cârla.ostberg@gmatl.6omSvedberg Residence277 JB CourtGarñeld County, ColoradoProjectNumben C1700l}atet o3l28tm22tes¡gne¿ ¡y: ceolReviewed by: RBlDrawn by: DDSheet 3 0F 4
STA TO WATER COURSE50'12't',STA TO WELL1006O EXISTING230'PROPOSEÐSEPTICTANKTOWELL 50' .Is'EXISTING35 PROPOSEDSEPTICTANKTOWATERCOURSE 50, 5?EXfST'NG59' PROPOSEÐHOTJSE TO SEPTIC TANK4gAPPROXIMATÉ PROPOSEDSETBACKOWTS COMPONËNTS ANI]PHYSICAL FEATURESMINIMUM REQUIREDSETBACKDESIGN2.BEDROOM RESIDENCEO5 GPD x 2 PERSONSiBEDROOM x 2 BEDROOMS)WASTFWATER FLOW = 300 GPDTANK;MIN. 600 GALLONS + CAPACITY FOR PUMPUSE 1OOÞGALLON, TWo-COMPARTMENT CONCRETE TRAFFIèRATEDSÊPTIC TANK WTH AN ORENCO PUMPING SYSTEM IN THE SECONDCOMPARTMENT4'DIA SDR-35 SEWER LINE(MrN 2% SLOPE TO TANK,MrN. 1olo TO STA)SCREENED24" MtN.3'MIN.8" MINÐIA VALVE BOXWITH SECURËD LID.5' PVC SLIP X MALEOR SAND FORBËDDINGSO¡L TREATMENT AREA (STA):LONG TERM ACCEPTANCE RATE (LTAR) = 0.35 GALJ SFCALCULATED STA = QITAR = 3O0 / 0.35 = 857 SFPRËSSURE DOSED, BED = 857 SF X 1.0 = 857 SFCHAMBÊRS = 857 SF X 0.7 = 600 SF / 12 SF /CHAMBÊR = 50 CIIAMBERSGRAVELLESS CHAMBER BED4 ROWS OF 13 'QUICK 4 CHAMBERSTOTAL 52 'QUICK 4' CHAMBERSSOIL PROFILE TËST PIT NO. 1NOTÉ: wAl'ER COURSE LOCATIONHAS BEÊN ÊSTIMATED ON SITE PLANSOIL PROFILE TEST PIT NO, 2DARK BROWN TOPSOILMEDIUM BROWN CLAY LOAMLEGEND?<¡ top$¡ln silVd¡avIomA'IRENCH BETAIL\rr-adw40ENCASËMËNT PIPÊ40 RIGID ENDEND CAP MUST BEGLUED OR SECUREDIN A WATER TIGHTFASHION WTHUNDERGROUNDSEALANTCAP Af EACH ENDOF PIPE-0-1-3-45DRILLED IN ENDDARKSROWN ÎOPSOILMEDIUM BROWN CLAY LOAMDIA SDR-35 SEWÊR LINÊ.CAP MIJST ONLY BELARGE ENOUGH TOALLOW SEWÊR LINE TOFIT THROUGIIFauIItsÀuoMUSTRESTON AOTTOMOF ENCASEMENT PIPEINSTALL DISCI.{ARGEPIPÊ ANO VALVEECCENTRICIOCENTER OF VAULTAENCÀSEMENT DEIAIL\9r-úflræPIPE THRÊADADAPTER WICAP1.5" DIA BALLVALVE-7_ö_'-10NO GROUNDWATER OR BEDROCK ENCOUNTERÊDDURING ËXCAVATION/ASOILS LOG\!t-..-TirfsE,5" OIA PVC LONGSWEEP 90' BÊNÐEND CAP^ FLUSIIING VAL\E DETAIL\9t-ôrTæw4.0CBO lnc.1æ Cains LaneCarbondale, Colorado 8 1 623Phone 970.309.5259cada.ostberg@gma¡l.comSvedberg Residence277 JB CourtGarfi eld County, ColoradoProjectNumbec C1700Shêet 4 0F 4
oFHCE
970-47L-O913
P.O. Box 1534
Eagle, CO 81631
altitudeseptic@gmail.com
www.altitudeseptic.com
07/26/2O2t
277 Jø Court,
Glenwood Springs, CO
Altitude Septic, LLC was hired to perform a Septic inspection at the above address. There are no records available
from the county on th¡s septic system. The current system at the main house has a 1000-gallon plastic septic tank
that has risers on the tank to bring access to the surtace. The risers are not sealed and can allow water in or out,
the ¡nlet and outlet tees are in place. The tank itself appears to be watertight, we also jetted and used a sewer
camera in the outlet to determine that the leach field is hotding water. There is an inspection port at the end of the
leach field, and it is holding water. This only further confirms that the leach field is failing. I would recommend
replacing this system.
The cabin on this property has a S0O-gallon single compartment plastic septic tank, this tank had normal levels and
is functioning as it should. There is an outlet tee present, and the tank has risers to the surface. The leach field area
shows no signs of failure, there are no inspection ports on this leach field.
A new leach field at current prices will run in the 530,000.00 range.
lf you have any questions, please give me a call
Jason
Altitude Septic, LLC
970-47t-L330
Please be aware of the following disclaimer: Altitude Sepfic accepfs no responsibility for the proper operation of this
sepfic sysfem. The septic sysfem is the property of the homeowner who rs respons/ble for the maintenance and operation
of this system. This inspectian does not constitute a guarantee nor is any warranty expressed or implied that the sysfem
wilt function properly in the future. Altitude Sepflc can only make obseruations based on the condition of the septic sysfem
at the time of inspection and will make no prediction on the future functionality of any pa¡f of the sepfic sysfem.
Legend'? 277 Jb ct277 JB CourtWrite a description for your map.d
G)qPublic.net'" Garfield County, CO
Account
Number
Parcel
Number
Acres
Land SqFt
TaxArea
2019Mill
Levy
R040303
2L23253W46
Physical
Address
Owner
Address
277 JBCT
GLENWOODSPRINGS
SVEDBERG, DAWN LINDA & STIG
LENNART
218 CONTESSA COURT
LAFAYETTE CA 94549
2019Total Actual
Value
Overview
Legend
i ì Parcels
Roads
Parcel/Account
Numbers
Highways
- LimitedAccess
- Highway
Major Road
Local Road
Minor Road
Other Road
Ramp
-- Ferry
Pedestrian Way
Owner Name
i I Lakes&Rívers
- CountyBoundary
Line
$688,170 Last2Sales
Date Price
9/7/2021 $O
9/A2O2t $B53,ooO
B1ó01
3
o
L23
79.4730
Date seated:317/2022
Last Datã Uploaded: 3/7 /2O22 2:03:27 ANI
Deve roned bv¡[.) pSårgtS!4çf
317122, 11:23 AM qPublic.net - Garfield County, CO - Property Record Card: R040303
G)qPublic.net "' Garfield County, CO
5ummary
Account
Parcel
Property
Address
Legal
Descr¡ption
Acres
Land SqFt
Tax Area
MillLevy
5ubdivision
RO40303
2123253c,o046
277 JB CT, GLENWOOD SPRINGS, CO 81ó01
Quarter: SW Section:25 Township: 5 Range: 904 TR CONT 2.5O Aç,
ALSO A TR CONT, ,22 AC. ALSO A TRACT OF LAND CONT. .046 AC.+/.
AS DESC. tN RECEPTION # 858415.
2.766
0
123
7?.4730
SVEDBERG, DAWN LINDA&STIG LENNART
218 CONTESSA COURT
LAFAYETTE CA 94549
Vieui Map
Owner
Land
UnitType
Square Feet
Buildings
Actual Values
Building#
Uníts
BuildingType
Abstract Codes/ (Property Typel
Architesturãl Style
Stories
Frame
Actual Year Built
Gross L¡ving Area
Total Heated SqFt
Bedrooms
Bâths
Heating Fuel
Heet¡ngType
AirConditioning
RoofType
Roof Cover
Buildlng #
Un¡ts
BuildincType
Abstrâct Codes / (Property Type)
Arch¡tectural Style
Stor¡es
Frame
Actual Year Built
Gross Living Area
Total Heated SqFt
Bedrooms
Bâths
Heating Fuel
HeatingType
Air Conditioning
RoofType
Roof Cover
SINGLE FAM.RES,-LAND. 1112 (RESIDENTIAL PROPERTY}
0
1
!
SFR
SINGLE FAM.RES.IMPROVEMTs-1212 (RESIDENTIAL PROPERTY)
2-STORY
7
WOODFRAME
7969
3,3ó3
J,JOJ
2
2
GA5
FORCEDAIR
NONE
HIP ROOF
PRO PANEL
7
SFR
SINGLE FAM.RES-IMPROVEMTS-1212 (RESIDENTIAL PROPERTY)
1 1/2 STRY
7
WOODFRAME
797t
514
514
1
o.75
wooD
WOODSTOVE
NONE
SHED
COMP SHNGL
Assessed Year
Lând Actual
2021
$19O,000.0o
$498,170.00
$ó88,170.00
2020
$220,000.00
$417,52O.OO
$ó37,520.00
lmprovement Actual
Total Actua¡
i:
{
:t
t
';
https://qpublic.schneidercorp.com/Application.âspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=94 47&Q=175227A204&KeyValue=R040303 114
317122, 11:23 AM
Assessed Values
qPublic.net - Garfield County, CO - Property Record Card: R040303
Assessed Year
Land Assessed
lmprovementAssessed
Total Assessed
Tax History
2079
53,448.60
2021
$13,s90.O0
$35,ó20.00
$49,210.00
2018
$3,217.20
2020
$15,730.00
$29,850.00
$4s,580.00
2017
$3,122.44
2A2r
$3,910.88
2020
ç3,427.36
Cl¡ck here to v¡ew the tåx information for this pârcel on the Garfield Countv Treasurer's webs¡te.
Transfers
Tax Year
Taxes Billed
Sale Date
9n/2427
9/A^AA-
9/9/2476
8/30/201.6
10/2/2074
at79/2074
4/24/2003
4/24/2003
4/24/2003
to/2417995
72/70/1992
9/2U1992
3t1UL992
3/27/7989
3/27179e7
3/27/7987
t2/12/7986
72/20t798s
6/3/1985
!/30tL981
7tt3/7987
77n/1980
Reception Number
962748
962747
882764
887727
858415
854853
628235
62A234
628233
485453
442056
439219
432449
380211
385911
380894
377148
367607
362147
371682
311109
309244
Book- Page Sale Príce
$o
$853,000
$o
$ó50,000
$o
$o
$o
$o
$o
$o
$137,000
$o
$o
$o
$o
$145,O00
$o
$o
$o
$o
$o
$o
Deed Type
QUITCLAIM DEED
SPECIALWARRANW DEED
AFFIDAVIT
WARRANÏY DEED
QUITCLAIM DEED
BOUNDARY LINE ADJUSIMENÏ
QUITCL.AIM DEED
STATEMENTOF AUTHORITY
STATEMËNT OF AUTHORITY
QUITCLAIM DEED
WARRANWÐEED
PUBLICTRUSTEES DEED
PUBTIC TRUSTEES CERÏ
WARRANryDEED
QUITCLAIM DEED
WARRANryDEED
QUITCLAIM DEED
SHERIFFS DEED UNDER FOREC
SHERIFFS CERTOF PUR
WARRANTYDEËD
Trustee's Deed
WARRANTY DEED
7474-376
1474-375
r474-374
0958-0735
0849-0482
oa42-o246
a825-O736
708-285
721-74
o709-o728
700-851
ó80-911
669-585
564-849
5ó3-58ó
559-724
Property Related Public Documents
Click here to view ProæIly l+E4eCÞIç-Dgç.Urnelts
Photos
Sketches
ei
I
t_!
Ê
https://qpublic.schneidercorp.com/Application.aspx?ApplD=1 038&LayerlD=22381 &PageTypelD=4&PagelD=9447&Q=1752270204&KeyValue=R040303 214
317122, 11:23 AM qPublic.net - Garfield County, CO - Property Record Card: R040303
9'
BIt. ln 1993
178.G sf
st.ç
5f
11
-N
r\l
d
11,
50.0 f
N
rD_
TWO
702.0 s
4
q
-c)
-fî
.N
f1¡
4'
14',
so-r
{4:''Ê'
PtQ
1s00.0 d
5'
I\J
Q-
6'
15'
i.5'
in112.0 sf
ONE
1075.û s
h
279.t ú
s'
21'\o- oNE
(D-
16'on¡e
208.0 d8' ¡\
0q t
9'
owA
-F"
153.0 sf
I'
https://qpublic.schneidercorp.com/Application.aspx?ApplD=1 038&LayerlD=22381 &PageTypelD=4&PagelD=9447 &Q=1752270204&KeyValue=R040303 314
317122, 11:23 AM qPublic.net - Garfìeld County, CO - Property Record Card: R040303
C.)9."blglçl
User Privacy Policy
GDPR Privacy Notice
Last Data Upload: 3/7/2022,I2:Q3:27 AM
https://qpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=94 47&Q=1752270204&KeyValue=R040303 414